Fujitsu BX960 S1 manual Instructions for connecting/disconnecting cables, Connecting cables

Page 39

Instructions for connecting/disconnecting cables

4.4Instructions for connecting/disconnecting cables

VCAUTION!

Be sure to read the documentation for the peripheral devices before connecting them.

Do not connect or disconnect data cables during a thunderstorm.

When removing a cable, always hold it by the plug. Never unplug a cable by pulling at the cable itself.

Connect and disconnect the cables in the order described below.

Connecting cables

ÊTurn off all power and equipment switches.

ÊDisconnect all power plugs from the grounded shockproof sockets.

ÊConnect all cables to the server and peripherals.

ÊPlug all data communication cables into the utility sockets.

ÊPlug all power cables into the grounded shockproof sockets.

Disconnecting cables

ÊTurn off all power and equipment switches.

ÊDisconnect all power plugs from the grounded shockproof sockets.

ÊUnplug all data communication cables from the utility sockets.

ÊDisconnect the relevant cables from the server and all the peripherals.

BX960 S1

Operating Manual

39

Image 39
Contents Primergy BX960 S1 Server Blade Certified documentation according to DIN EN ISO Comments… Suggestions… Corrections…Aluminum electrolytic capacitors For your safetyHigh safety use Radio interferenceMeasures against momentary voltage drop Harmonic Current StandardsOnly for the Japanese market About Sata hard disk drives Only for the Japanese market Operating Manual Contents Contents Concept and target groups for this manual IntroductionDocumentation overview Documentation overviewPerformance features Performance features Further sources of informationCustomer Self Service CSS Slots for expansion cards Performance featuresSystem board Trusted Platform Module TPMExternal ports SSD drivesSATA-RAID support Graphics controllerIRMC S2 with integrated management LAN connector Server management Service and support Performance features ServerView Installation ManagerNotational conventions Notational conventionsCompliance with regulations and standards Technical dataTechnical data Electrical dataAmbient conditions Technical data CertificationMechanical specifications WeightTechnical data Overview Installation steps BX960 S1 Important notes Safety instructionsInstallation and operation Safety instructions Before starting upSafety instructions Safety instructions Batteries Operating Manual Never remove parts of the optical drive casing Laser informationESD label CE conformity Other important information CE conformityFCC class a device Transporting the Server BladePackaging information Environmental protectionEnvironmentally-friendly product design and development Energy-saving informationEnvironmental protection Labels on plastic casing partsReturns, recycling and disposal Installing the hardware Minimum acclimatization timeHours Installing the Server Blade in the system unit Unpacking the serverUnpacking the server Removing the server blade dummy module Installing the Server Blade Installing the Server BladeConnecting devices Connecting devicesSAN Disconnecting cables Instructions for connecting/disconnecting cablesInstructions for connecting/disconnecting cables Connecting cablesInstructions for connecting/disconnecting cables Control and display elements Installation and operationLEDs on the control panel Control and display elements Control elementsCSS Control and display elementsID card Other On/Off options After power failure Switching the Server Blade on and offSwitching the Server Blade on and off Defined switch-on/off timeConfiguring the Server Blade Configuring the Server BladeAdvantages of the ServerView Installation Manager Installing the operating system Onboard Sata controller, configuringCleaning the Server Blade Cleaning the Server BladeCleaning the Server Blade Property and data protection Bios Setup security functionsPreventing unauthorized Bios Setup calls Preventing unauthorized system accessProtecting the server from being switched off by a program Protecting Bios from being overwrittenMonitor is switched off Troubleshooting and tipsServer switches itself off Server Management has detected an errorBrightness control is set to dark Power cable or monitor cable not connectedFlickering stripes on monitor screen1 Flickering stripes on monitor screen Screen has gone blankIncorrect date and time System will not bootSAS configuration incorrect No screen display or display drifts1RAID controller configuration incorrect Hard disk drive error messages at system bootAdded drive reported as defective Error message on screenRAID controller is not configured for this drive Added drive reported as defectiveError message on screen Replacing CSS components SSD drive SSD driveRemoving the server blade from the system unit Opening the server bladeRemoving the cover SSD drive Removing the coverRemoving an SSD drive Replacing the SSD driveRemoving the SSD drive mounting frame Fitting the SSD drive into the guide element SSD drive Installing an SSD driveInserting the SSD drive in the mounting frame Installing the mezzanine cards carrier Closing the server blade Index BiosCSS Index FaultUFM IndexWeight Operating Manual