Fujitsu BX960 S1 manual Protecting Bios from being overwritten

Page 52

BIOS Setup security functions

Preventing unauthorized writing to floppy disks

To activate this protection, select the value Disabled for the Diskette Write field in the Security menu.

Protecting BIOS from being overwritten

To activate this protection, select the value Disabled for the Flash Write field in the Security menu.

Protecting the server from being switched on by an external device

To activate this protection, select the value Disabled for the Remote Power On field in the Security menu.

Protecting the server from being switched off by a program

To activate this protection select the value Disabled for the Soft Power Off field in the Security menu.

52

Operating Manual

BX960 S1

Image 52
Contents Primergy BX960 S1 Server Blade Comments… Suggestions… Corrections… Certified documentation according to DIN EN ISOFor your safety High safety useRadio interference Aluminum electrolytic capacitorsHarmonic Current Standards Measures against momentary voltage dropOnly for the Japanese market About Sata hard disk drives Only for the Japanese market Operating Manual Contents Contents Introduction Concept and target groups for this manualDocumentation overview Documentation overviewPerformance features Further sources of information Performance featuresCustomer Self Service CSS Performance features System boardTrusted Platform Module TPM Slots for expansion cardsSSD drives SATA-RAID supportGraphics controller External portsIRMC S2 with integrated management LAN connector Server management Performance features ServerView Installation Manager Service and supportNotational conventions Notational conventionsTechnical data Technical dataElectrical data Compliance with regulations and standardsTechnical data Certification Mechanical specificationsWeight Ambient conditionsTechnical data Overview Installation steps BX960 S1 Safety instructions Important notesSafety instructions Before starting up Installation and operationSafety instructions Safety instructions Batteries Operating Manual Laser information Never remove parts of the optical drive casingESD label CE conformity FCC class a deviceTransporting the Server Blade CE conformity Other important informationEnvironmental protection Environmentally-friendly product design and developmentEnergy-saving information Packaging informationLabels on plastic casing parts Environmental protectionReturns, recycling and disposal Minimum acclimatization time Installing the hardwareHours Unpacking the server Installing the Server Blade in the system unitUnpacking the server Removing the server blade dummy module Installing the Server Blade Installing the Server BladeConnecting devices Connecting devicesSAN Instructions for connecting/disconnecting cables Instructions for connecting/disconnecting cablesConnecting cables Disconnecting cablesInstructions for connecting/disconnecting cables Installation and operation Control and display elementsControl and display elements Control elements LEDs on the control panelControl and display elements CSSID card Switching the Server Blade on and off Switching the Server Blade on and offDefined switch-on/off time Other On/Off options After power failureConfiguring the Server Blade Configuring the Server BladeAdvantages of the ServerView Installation Manager Onboard Sata controller, configuring Installing the operating systemCleaning the Server Blade Cleaning the Server BladeCleaning the Server Blade Bios Setup security functions Preventing unauthorized Bios Setup callsPreventing unauthorized system access Property and data protectionProtecting Bios from being overwritten Protecting the server from being switched off by a programTroubleshooting and tips Server switches itself offServer Management has detected an error Monitor is switched offPower cable or monitor cable not connected Flickering stripes on monitor screen1Flickering stripes on monitor screen Screen has gone blank Brightness control is set to darkSystem will not boot SAS configuration incorrectNo screen display or display drifts1 Incorrect date and timeHard disk drive error messages at system boot RAID controller configuration incorrectError message on screen RAID controller is not configured for this driveAdded drive reported as defective Added drive reported as defectiveError message on screen Replacing CSS components SSD drive SSD driveOpening the server blade Removing the server blade from the system unitSSD drive Removing the cover Removing the coverReplacing the SSD drive Removing an SSD driveRemoving the SSD drive mounting frame SSD drive Installing an SSD drive Fitting the SSD drive into the guide elementInserting the SSD drive in the mounting frame Installing the mezzanine cards carrier Closing the server blade Bios IndexIndex Fault CSSIndex UFMWeight Operating Manual