Extensions and conversions

Introduction

The Technical Manual for the system board D1979 (PDF available on the

ServerBooks CD supplied)

The “BIOS Setup” manual (PDF available on the ServerBooks CD supplied)

The “PRIMERGY ServerView Suite - ServerStart” manual (printed copy always supplied with the server, and available as PDF file on the ServerBooks CD supplied)

The “Global Array Manager Client Software User’s Guide” (PDF available on the ServerBooks CD supplied)

The “Integrated Mirroring User’s Guide” (PDF available on the ServerBooks CD supplied)

IYou can order a supplementary ServerBooks CD by sending an e-mail to the following address, quoting your server data:

Reklamat-PC-LOG@fujitsu-siemens.com

Further sources of information:

Technical Manual on the relevant rack

Manual on the monitor

Manual on ServerView Server Management

Manual on the RemoteView Remote Test and Diagnostics System

Documentation on boards and drives

Documentation on your operating system

Information files on your operating system

(see also “Related publications” on page 79)

1.2Extensions and conversions

Extension of the main memory

The four slots for the main memory are suitable for DDR1 333/400 MHz (unbuf- fered) SDRAM memory modules. The organization in two memory banks, 1 and 2, permits rapid memory access with two-way interleaving.

If the memory modules are populated in pairs, each pair must consist of identical memory modules (2-way interleaved mode).

Additional SATA hard disk drives

In the SATA version four bays are available for SATA hard disk drives.

2

Options Guide

U41604-Z156-1-76

Image 10
Contents Primergy TX150 S3 Server System Copyright and Trademarks Comments… Suggestions… Corrections…Certified documentation according to DIN EN ISO Page Page Page Page Contents Contents Concept and target groups IntroductionOverview of the documentation Additional documentation about the serverFurther sources of information Extensions and conversionsExtensions and conversions Extension of the main memoryHard disks extension box Additional accessible drivesIntroduction Additional controllers in the PCI slotsNotational conventions Conversion standard power supply to hot-plug power supplyNotational conventions Conversion of the floorstand model to a rack modelProcedure Page Safety notes Before operating the deviceSafety notes Installation and operation Safety notes Safety notes Batteries Never remove parts of the CD-/DVD-ROM drive assembly Safety notes Modules with electrostatic-sensitive components Floorstand model PreparationOpening the server Removing the front cover Floorstand modelRemoving the hard disk cover PreparationRack model Rack modelRack model Loosening the screws Removing the rack front cover Removing the rack front coverPage Main memory Equipping rulesExtending/replacing the main memory Extending/replacing the main memoryMain memory Inserting a memory modulePage Accessible drives Installing an accessible 5.25-inch driveInstalling an accessible 5.25-inch drive Attaching the EasyClick rails DVD-ROM burnerAccessible drives Attaching the EasyClick rails magnetic tape drive VXA-2 Installing the hard disks extension box Installing the hard disks extension box Attaching the EasyClick railsController in the PCI slots PCIe Slot PCI SlotInstalling a controller Installing a controllerInstalling a controller Controller in the PCI slotsPCI slot assembling PCI slot assemblingRemoteView Service Board S2 LP RemoteView componentsRemoteView components RSB S2 LP RemoteView Service Board S2 LP Installing the external Scsi interface External Scsi interfacePage Conversion standard PS to hot- plug PS Taking out the standard power supply Installing the Power backplane in the PS cage Installing the PS cage Fastening the PS cage in the housing Fastening the PS cage at the rear side Inserting the power supply module Locking the power supply module Installing the dummy cover Mounting the anti-tilt bracket Fastening the anti-tilt bracket Page Converting from the floorstand model to the rack model Removing the anti-tilt bracketRight-hand side cover and the top cover build one part Removing the rubber feet Installing the operating panel module Converting from the floorstand model to the rack model Page Completion Attaching the hard disk coverAttaching the front cover Attaching the front coverClosing the server CompletionAttaching the rack front cover Attaching the plastic front coverAttaching the rack front cover Attaching the top cover Installing the server in a rack cabinet Rack model Completion Fastening the server in the rack cabinetScsi version AppendixCabling Channel Scsi version with onboard Scsi controllerScsi Cabling RAIDIDE/FD Data Cable prefix T26139 Sata version ControllerPage Abbreviations Abbreviations HDD MRL SCA Page Related publications Related Publications Index Page Comments Suggestions Corrections Page Comments Suggestions Corrections Page Information on this document Hinweise zum vorliegenden Dokument