Fujitsu TX150 S3 manual Taking out the standard power supply

Page 50

Conversion standard PS to hot-plug PS

1 1

Figure 29: Loosening the screws

ÊRemove the five screws (1) which attach the adapter plate of the standard power supply to the housing.

2

Figure 30: Taking out the standard power supply

ÊSlide the standard power supply somewhat toward the inside (1) to detach it from the brackets in the side cover and take it out toward the side (2).

42

Options Guide

U41604-Z156-1-76

Image 50
Contents Primergy TX150 S3 Server System Certified documentation according to DIN EN ISO Comments… Suggestions… Corrections…Copyright and Trademarks Page Page Page Page Contents Contents Concept and target groups IntroductionOverview of the documentation Additional documentation about the serverFurther sources of information Extensions and conversionsExtensions and conversions Extension of the main memoryHard disks extension box Additional accessible drivesIntroduction Additional controllers in the PCI slotsNotational conventions Conversion standard power supply to hot-plug power supplyNotational conventions Conversion of the floorstand model to a rack modelProcedure Page Safety notes Before operating the deviceSafety notes Installation and operation Safety notes Safety notes Batteries Never remove parts of the CD-/DVD-ROM drive assembly Safety notes Modules with electrostatic-sensitive components Opening the server PreparationFloorstand model Removing the front cover Floorstand modelRemoving the hard disk cover PreparationRack model Rack modelRack model Loosening the screws Removing the rack front cover Removing the rack front coverPage Main memory Equipping rulesExtending/replacing the main memory Extending/replacing the main memoryMain memory Inserting a memory modulePage Accessible drives Installing an accessible 5.25-inch driveInstalling an accessible 5.25-inch drive Attaching the EasyClick rails DVD-ROM burnerAccessible drives Attaching the EasyClick rails magnetic tape drive VXA-2 Installing the hard disks extension box Installing the hard disks extension box Attaching the EasyClick railsController in the PCI slots PCIe Slot PCI SlotInstalling a controller Installing a controllerInstalling a controller Controller in the PCI slotsPCI slot assembling PCI slot assemblingRemoteView Service Board S2 LP RemoteView componentsRemoteView components RSB S2 LP RemoteView Service Board S2 LP Installing the external Scsi interface External Scsi interfacePage Conversion standard PS to hot- plug PS Taking out the standard power supply Installing the Power backplane in the PS cage Installing the PS cage Fastening the PS cage in the housing Fastening the PS cage at the rear side Inserting the power supply module Locking the power supply module Installing the dummy cover Mounting the anti-tilt bracket Fastening the anti-tilt bracket Page Converting from the floorstand model to the rack model Removing the anti-tilt bracketRight-hand side cover and the top cover build one part Removing the rubber feet Installing the operating panel module Converting from the floorstand model to the rack model Page Completion Attaching the hard disk coverAttaching the front cover Attaching the front coverClosing the server CompletionAttaching the rack front cover Attaching the plastic front coverAttaching the rack front cover Attaching the top cover Installing the server in a rack cabinet Rack model Completion Fastening the server in the rack cabinetScsi version AppendixCabling Channel Scsi version with onboard Scsi controllerScsi Cabling RAIDIDE/FD Data Cable prefix T26139 Sata version ControllerPage Abbreviations Abbreviations HDD MRL SCA Page Related publications Related Publications Index Page Comments Suggestions Corrections Page Comments Suggestions Corrections Page Information on this document Hinweise zum vorliegenden Dokument