Fujitsu MAV2036RC, MAV2073RC manual Error rate, Reliability, Mtbf=

Page 27

2.1 Hardware Specifications

(*1) For detail condition, see Section 4.1.

(*2) Vibration applied to the drive is measured at near the mounting screw hole on the frame as much as possible.

(*3) At random seek write/read and default on retry setting with log sweep vibration.

(*4) At power-off state after installation

Vibration displacement should be less than 2.5 mm.

(*5) Input voltages are specified at the drive connector side, during drive ready state.

(*6) High frequency noise (over 20MHz) is less than 100 mVp-p.

2.1.4Error rate

Errors detected during initialization and replaced by alternate block assignments are not included in the error rate. Data blocks to be accessed should be distributed over the disk medium equally.

(1)Unrecoverable error rate

Errors which cannot be recovered within 63 retries and ECC correction should not exceed 10 per 1016 bits read.

(2)Positioning error rate

Positioning errors which can be recovered by one retry should be 10 or less per 108 seeks.

2.1.5Reliability

(1)Mean Time Between Failures (MTBF)

MTBF of the HDD during its life time is 1,400,000 hours (operating: 24 hours/day, 7 days/week

average DE surface temperature: 50°C or less).

Note:

The MTBF is defined as:

Operating time (hours) at all field sites

MTBF=

The number of equipment failures from all field sites

Failure of the equipment means failure that requires repair, adjustments, or replacement. Mishandling by the operator, failures due to bad environmental conditions, power trouble, host system trouble, cable failures, or other failures not caused by the equipment are not considered.

C141-E219

2-5

Image 27
Contents C141-E219-01EN For Safe Operation Revision Record Related Standards Overview of Manual PrefaceConventions for Alert Messages PrefaceImportant Alert Messages Important Alert ItemsData loss Important Alert ItemsInterface Maintenance ManualSpecifications Manual Organization ProductThis page is intentionally left blank Contents Contents InstallationTroubleshooting with disk drive replacement in the field Troubleshooting with parts replacement in the factorySense data 4-44-xx, 5-2x-xx, B-44-xx, B-47-xx, B-4B-xx Figures Tables This page is intentionally left blank General Description Standard Features Hardware Structure System ConfigurationGeneral Description Standard FeaturesStandard Features General Description Hardware Structure System Configuration Hardware Specifications Hardware Specifications Model name and order numberModel names and order numbers 32/34 Meeprml Specifications Function specifications MAV2073RC MAV2036RCHardware Specifications Environmental/Power requirements Environmental specificationsError rate ReliabilityMTBF= Specifications Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Data Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements Dimensions Installation RequirementsMounting orientations Installation RequirementsMounting Requirements Mounting frame structure MPU Surface temperature check point and maximum temperatureConnection Requirements HDCService clearance area Current waveform +12V DC Power Supply RequirementsConnector location 10 SAS plug connector overview Interface connectorInterface connector SAS plug signal allocationCN1 Installation Installation Setting Setting Port AddressMounting Drives Mounting procedures Installation Formatting Installation Setting parameters Awre ArreArre Awre PER Disc XffffXxxx Dismounting Drives Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Precautions Maintenance InformationMaintenance requirements Revision numbers Maintenance levelsIndicating revision numbers Tools and test equipment Tests Test flowchartDiagnostic test Operation Check Initial seek operation checkOperation test Troubleshooting with disk drive replacement in the field Troubleshooting ProceduresSystem-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense data Error Analysis Information Collection Sense Data AnalysisSksv Error AnalysisILI LSBDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorGlossary Target Targ GlossaryAcronyms and Abbreviations SAS Acronyms and AbbreviationsECC BcrcPAD Mode SELECT/MODE SelectIndex Mtbf MttrC141-E219 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank