Fujitsu MAV2073RC, MAV2036RC manual Write Write Extended Format Unit

Page 42

Data Format

Type 2 (Reassignment of write fail sector)

1)Commands to be applied

-WRITE

-WRITE EXTENDED

-FORMAT UNIT

-WRITE at executing WRITE AND VERIFY

2)Application requirements / processing

When WRITE/WRITE EXTENDED command detects any Servo error (e.g. Write offtrack error) and cannot be recovered within pre-determined retry number (specified in Mode Parameter). For the sectors around defective Servo, alternate blocks are allocated and the data of this WRITE commands are re-written.

Sectors to be made AWRE shall be following:

-the sector where the error occurs and the latter sectors and,

-the sectors whose data are logically continual and stored in Cache,

-the sectors which will be processed in this Write command and,

-the sectors which locate between erroneous Servo -1 and +1 (including Split sector)

This function is also applied for the sector that has already been re-assigned. Remark:

When a write protection is prohibited through the setting terminal, the auto alternate block allocation processing specification is disabled.

Automatic alternate block allocation is made up to the following quantities during the execution of one command:

ARRE = Twice

AWRE (Type 1) = Eight times

AWRE (Type 2) = Maximum number which can be processed within the recovery time limit

If more than the above mentioned defective block is detected, the alternate block assignment processing for the first defective block is executed but the alternate block assignment processing for the second one is not executed and the command being executed terminates. However, the initiator can recover the twice error by issuing the same command again.

When an error is detected in a data block in the data area, recovery data is rewritten and verified in automatic alternate block allocation during the execution of the READ or READ EXTENDED command. Alternate block allocation will not be made for the data block if recovery is successful.

Example: Even if the data error which is recoverable by the WRITE LONG command is simulated, automatic alternate block allocation will not be made for the data block.

3-14

C141-E219

Image 42
Contents C141-E219-01EN For Safe Operation Revision Record Related Standards Preface Overview of ManualPreface Conventions for Alert MessagesImportant Alert Items Important Alert MessagesImportant Alert Items Data lossManual Organization Product Maintenance ManualSpecifications InterfaceThis page is intentionally left blank Contents Installation ContentsTroubleshooting with disk drive replacement in the field Troubleshooting with parts replacement in the factorySense data 4-44-xx, 5-2x-xx, B-44-xx, B-47-xx, B-4B-xx Figures Tables This page is intentionally left blank Standard Features Hardware Structure System Configuration General DescriptionStandard Features General DescriptionStandard Features General Description Hardware Structure System Configuration Hardware Specifications Hardware Specifications Model name and order numberModel names and order numbers MAV2073RC MAV2036RC SpecificationsFunction specifications 32/34 MeeprmlHardware Specifications Environmental specifications Environmental/Power requirementsError rate ReliabilityMTBF= Specifications Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Data Space Alternate spare area Spare area in cellTrack format Track skew/head skew Sector formatData Space Format capacity Logical Data Block Addressing Defect Management Defect list Alternate block allocation Alternate block allocation by Format Unit command Defect ManagementAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Installation Requirements Mounting Requirements DimensionsInstallation Requirements Mounting orientationsMounting Requirements Mounting frame structure HDC Surface temperature check point and maximum temperatureConnection Requirements MPUService clearance area Power Supply Requirements Current waveform +12V DCConnector location Interface connector 10 SAS plug connector overviewInterface connector SAS plug signal allocationCN1 Installation Installation Setting Setting Port AddressMounting Drives Mounting procedures Installation Formatting Installation Setting parameters Awre ArreArre Awre PER Disc XffffXxxx Dismounting Drives Diagnostics Self-diagnostics Self-diagnostic functionsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information PrecautionsMaintenance requirements Maintenance levels Revision numbersIndicating revision numbers Tools and test equipment Test flowchart TestsDiagnostic test Operation Check Initial seek operation checkOperation test Troubleshooting Procedures Troubleshooting with disk drive replacement in the fieldSystem-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsError Analysis Information Collection Sense Data Analysis Error Analysis Information Collection Sense dataLSB Error AnalysisILI SksvSense Data Analysis Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, and 4-C4-xxGlossary Glossary Target TargAcronyms and Abbreviations Acronyms and Abbreviations SASBcrc ECCMtbf Mttr Mode SELECT/MODE SelectIndex PADC141-E219 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank