Fujitsu MAV2036RC, MAV2073RC manual Bcrc, Ecc

Page 85

Index

A

 

AC noise filter

4-8

actuator

1-5

allowable input voltage and current

4-7

alternate area

3-9

alternate block allocation

3-10

alternate block allocation by FORMAT

 

UNIT command

3-11

alternate block allocation by REASSIGN

 

BLOCKS command

3-12

alternate block allocation during

 

FORMAT UNIT command execution ....

3-11

alternate cylinder

3-4

alternate spare area

3-4

automatic alternate block allocation

3-13

automatic alternate block allocation at

 

read operation

3-13

automatic alternate block allocation at

 

write operation

3-13

automatic alternate block reassignment

1-3

B

 

basic operation test

6-4

BCRC

3-7

block address of user space

3-9

block descriptor

5-5

C

 

cache feature

1-3

caching parameter

5-9

changing revision number in field

6-8

checking at abnormal end

5-5

checking initial operation

5-4

checking operation after installation and

 

preparing HDD for use

5-4

command queuing feature

1-3

compactness

1-2

connection requirement

4-8

connector

4-8

continuous block processing

1-2

control mode parameter

5-9

controller circuit

1-5

current waveform

4-7

cylinder configuration

3-1

D

 

data field

3-7

data format

3-1

data security at power failure

2-6

data space

3-1

defect list

3-10

defect management

3-10

defective block slipping

1-4

definition of sense data

7-3

delivery

5-2

diagnosis

1-4

diagnostic

6-1

diagnostic test

6-10

diagnostics and maintenance

6-1

dimension

4-1

disk

1-5

disk drive replacement

6-7

disk drive troubleshooting

6-13

disk read error

7-4

dismounting drive

5-10

E

 

ECC

3-7

environmental magnetic field

4-6

environmental specification

2-4

environmental temperature

4-5

environmental/power requirement

2-4

error analysis

7-1

error analysis information collection

7-1

error information indicated with sense

 

data

7-3

error rate

2-5

error recovery

1-3

error recovery during self-diagnostic

6-3

error recovery parameter

5-8

example of SAS system configuration

1-6

examples of mounting frame structure

4-3

F

 

factory maintenance

6-7

field maintenance

6-7

finding possibly faulty part

6-14

format capacity

3-8

format of extended sense data

7-2

format parameter

5-5, 5-6

FORMAT UNIT command

5-6

formatting

5-5

function specification

2-2

G

 

gap

3-7

general description

1-1

C141-E219

IN-1

Image 85
Contents C141-E219-01EN For Safe Operation Revision Record Related Standards Overview of Manual PrefaceConventions for Alert Messages PrefaceImportant Alert Messages Important Alert ItemsData loss Important Alert ItemsSpecifications Maintenance ManualManual Organization Product InterfaceThis page is intentionally left blank Contents Contents InstallationTroubleshooting with parts replacement in the factory Troubleshooting with disk drive replacement in the fieldSense data 4-44-xx, 5-2x-xx, B-44-xx, B-47-xx, B-4B-xx Figures Tables This page is intentionally left blank General Description Standard Features Hardware Structure System ConfigurationGeneral Description Standard FeaturesStandard Features General Description Hardware Structure System Configuration Hardware Specifications Model name and order number Hardware SpecificationsModel names and order numbers Function specifications SpecificationsMAV2073RC MAV2036RC 32/34 MeeprmlHardware Specifications Environmental/Power requirements Environmental specificationsReliability Error rateMTBF= Specifications Data Space Logical Data Block Addressing Defect Management Cylinder configurationData Space Data Format Data Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements Dimensions Installation RequirementsMounting orientations Installation RequirementsMounting Requirements Mounting frame structure Connection Requirements Surface temperature check point and maximum temperatureHDC MPUService clearance area Current waveform +12V DC Power Supply RequirementsConnector location 10 SAS plug connector overview Interface connectorInterface connector SAS plug signal allocationCN1 Installation Installation Setting Port Address SettingMounting Drives Mounting procedures Installation Formatting Installation Setting parameters Arre AwreArre Awre PER Xffff DiscXxxx Dismounting Drives Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Precautions Maintenance InformationMaintenance requirements Revision numbers Maintenance levelsIndicating revision numbers Tools and test equipment Tests Test flowchartOperation Check Initial seek operation check Diagnostic testOperation test Troubleshooting with disk drive replacement in the field Troubleshooting ProceduresSystem-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense data Error Analysis Information Collection Sense Data AnalysisILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorGlossary Target Targ GlossaryAcronyms and Abbreviations SAS Acronyms and AbbreviationsECC BcrcIndex Mode SELECT/MODE SelectMtbf Mttr PADC141-E219 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank