Table 4.2 Interface connector (SAS plug) signal allocation:CN1

Pin No.

Signal

Description

S1

GND

GND for SAS Primary Port

S2

RP+

SAS Primary Port Receive(positive) signal

S3

RP-

SAS Primary Port Receive(negative) signal

S4

GND

GND for SAS Primary Port

S5

TP-

SAS Primary Port Transmit(negative) signal

S6

TP+

SAS Primary Port Transmit(positive) signal

S7

GND

GND for SAS Primary Port

S8 Note1

GND

GND for SAS Secondary Port

S9 Note1

Reserved (not used)

Not used

S10 Note1

Reserved (not used)

Not used

S11 Note1

GND

GND for SAS Secondary Port

S12 Note1

Reserved (not used)

Not used

S13 Note1

Reserved (not used)

Not used

S14 Note1

GND

GND for SAS Secondary Port

P1 Note2

Reserved (not used)

Not used

P2 Note2

Reserved (not used)

Not used

P3 Note2

Reserved (not used)

Not used

P4

GND

GROUND

P5

GND

GROUND

P6

GND

GROUND

P7

+5V-Charge

Pre-charge pin for +5V

P8

+5V

+5V power supply input

P9

+5V

+5V power supply input

P10

GND

GROUND

P11

READY LED

READY LED output

P12

GND

GROUND

P13

+12V-Charge

Pre-charge pin for +12V

P14

+12V

+12V power supply input

P15

+12V

+12V power supply input

Note 1) S8 - S14 are SAS Secondary Port signals, and not used on MAV2073RC and MAV2036RC.

Note 2) P1 to P3 are 3.3V power supply input and pre-charge signals, and not used on MAV2073RC and MAV2036RC.

4-10

C141-E219

Image 52
Contents C141-E219-01EN For Safe Operation Revision Record Related Standards Preface Overview of ManualPreface Conventions for Alert MessagesImportant Alert Items Important Alert MessagesImportant Alert Items Data lossMaintenance Manual SpecificationsManual Organization Product InterfaceThis page is intentionally left blank Contents Installation ContentsTroubleshooting with parts replacement in the factory Troubleshooting with disk drive replacement in the fieldSense data 4-44-xx, 5-2x-xx, B-44-xx, B-47-xx, B-4B-xx Figures Tables This page is intentionally left blank Standard Features Hardware Structure System Configuration General DescriptionStandard Features General DescriptionStandard Features General Description Hardware Structure System Configuration Hardware Specifications Model name and order number Hardware SpecificationsModel names and order numbers Specifications Function specificationsMAV2073RC MAV2036RC 32/34 MeeprmlHardware Specifications Environmental specifications Environmental/Power requirementsReliability Error rateMTBF= Specifications Data Space Logical Data Block Addressing Defect Management Cylinder configurationData Space Data Format Data Space Alternate spare area Spare area in cellTrack format Track skew/head skew Sector formatData Space Format capacity Logical Data Block Addressing Defect Management Defect list Alternate block allocationAlternate block allocation by Format Unit command Defect ManagementAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Installation Requirements Mounting Requirements DimensionsInstallation Requirements Mounting orientationsMounting Requirements Mounting frame structure Surface temperature check point and maximum temperature Connection RequirementsHDC MPUService clearance area Power Supply Requirements Current waveform +12V DCConnector location Interface connector 10 SAS plug connector overviewInterface connector SAS plug signal allocationCN1 Installation Installation Setting Port Address SettingMounting Drives Mounting procedures Installation Formatting Installation Setting parameters Arre AwreArre Awre PER Xffff DiscXxxx Dismounting Drives Diagnostics Self-diagnostics Self-diagnostic functionsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information PrecautionsMaintenance requirements Maintenance levels Revision numbersIndicating revision numbers Tools and test equipment Test flowchart TestsOperation Check Initial seek operation check Diagnostic testOperation test Troubleshooting Procedures Troubleshooting with disk drive replacement in the fieldSystem-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsError Analysis Information Collection Sense Data Analysis Error Analysis Information Collection Sense dataError Analysis ILILSB SksvSense Data Analysis Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, and 4-C4-xxGlossary Glossary Target TargAcronyms and Abbreviations Acronyms and Abbreviations SASBcrc ECCMode SELECT/MODE Select IndexMtbf Mttr PADC141-E219 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank