Fujitsu MAV2036RC, MAV2073RC manual Disc, Xffff, Xxxx

Page 61

5.4Checking Operation after Installation and Preparing the HDD for Use

(2)Caching parameters

The following parameters are used to optimize HDD Read-Ahead caching operations under the system environments. Refer to Chapter 3 “Data Buffer Management” of the Serial Attached SCSI Interface Specifications for further details.

 

Parameter

 

Default value

 

 

 

 

• IC:

Initiator control

 

0 (Drive-specific

 

 

 

control (page

 

 

 

cache))

• RCD:

Disabling Read-Ahead caching operations

 

0 (enabled)

• WCE:

Write Cache Enable

 

1 (enabled)

• MS:

Specifying the multipliers of "minimum

 

0 (Specifying

 

prefetch" and "maximum prefetch" parameters

 

absolute value)

• DISC:

Prefetch operation after track switching during

 

1 (enabled)

 

prefetching

 

 

• Number of blocks for which prefetch is suppressed

 

X'FFFF'

• Minimum prefetch

 

X'0000'

• Maximum prefetch

 

X' XXXX'

 

 

 

(1 cache segment)

• Number of blocks with maximum prefetch restrictions

 

X'FFFF'

• Number of segments

 

X'08'

Notes:

1.When Read-Ahead caching operations are disabled by the caching parameter, these parameter settings have no meaning except write cache feature.

2.Determine the parameters in consideration of how the system accesses the disk. When the access form is not determined uniquely because of the processing method, the parameters can be re-set actively.

3.For sequential access, the effective access rate can be increased by enabling Read-Ahead caching operations and Write Cache feature.

(3)Control mode parameters

The following parameters are used to control the tagged queuing and error logging. a. Control mode parameters

 

Parameter

 

Default value

• Queue algorithm modifier

 

0 (Execution sequence of

 

 

 

read/write commands is

 

 

 

optimized.)

• QErr:

Resume or abort remaining suspended

 

0 (command is resumed)

 

commands after sense pending state

 

 

• DQue:

Disabling tagged command queuing

 

0 (enabled)

C141-E219

5-9

Image 61
Contents C141-E219-01EN For Safe Operation Revision Record Related Standards Overview of Manual PrefaceConventions for Alert Messages PrefaceImportant Alert Messages Important Alert ItemsData loss Important Alert ItemsSpecifications Maintenance ManualManual Organization Product InterfaceThis page is intentionally left blank Contents Contents InstallationTroubleshooting with parts replacement in the factory Troubleshooting with disk drive replacement in the fieldSense data 4-44-xx, 5-2x-xx, B-44-xx, B-47-xx, B-4B-xx Figures Tables This page is intentionally left blank General Description Standard Features Hardware Structure System ConfigurationGeneral Description Standard FeaturesStandard Features General Description Hardware Structure System Configuration Hardware Specifications Model name and order number Hardware SpecificationsModel names and order numbers Function specifications SpecificationsMAV2073RC MAV2036RC 32/34 MeeprmlHardware Specifications Environmental/Power requirements Environmental specificationsReliability Error rateMTBF= Specifications Data Space Logical Data Block Addressing Defect Management Cylinder configurationData Space Data Format Data Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements Dimensions Installation RequirementsMounting orientations Installation RequirementsMounting Requirements Mounting frame structure Connection Requirements Surface temperature check point and maximum temperatureHDC MPUService clearance area Current waveform +12V DC Power Supply RequirementsConnector location 10 SAS plug connector overview Interface connectorInterface connector SAS plug signal allocationCN1 Installation Installation Setting Port Address SettingMounting Drives Mounting procedures Installation Formatting Installation Setting parameters Arre AwreArre Awre PER Xffff DiscXxxx Dismounting Drives Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Precautions Maintenance InformationMaintenance requirements Revision numbers Maintenance levelsIndicating revision numbers Tools and test equipment Tests Test flowchartOperation Check Initial seek operation check Diagnostic testOperation test Troubleshooting with disk drive replacement in the field Troubleshooting ProceduresSystem-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense data Error Analysis Information Collection Sense Data AnalysisILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorGlossary Target Targ GlossaryAcronyms and Abbreviations SAS Acronyms and AbbreviationsECC BcrcIndex Mode SELECT/MODE SelectMtbf Mttr PADC141-E219 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank