Fujitsu MAV2036RC, MAV2073RC manual Write Write Extend

Page 41

3.3 Defect Management

(3)Automatic alternate block allocation

• Automatic alternate block allocation at read operation

If the ARRE flag in the MODE SELECT parameter permits the automatic alternate block allocation, the HDD automatically executes the alternate block allocation and data duplication on the defective data block detected during the READ or READ EXTENDED command. This allocation method is the same as with the REASSIGN BLOCKS command (alternate sector treatment).

Automatic alternate block allocation at write operation

If AWRE flag in the MODE SELECT parameter permits the automatic alternate block allocation, the HDD executes two kinds of automatic alternate processing during WRITE command processing as described below:

Type 1 (Reassignment of Uncorrectable Read Error)

1)Commands to be applied

-WRITE

-WRITE EXTEND

-WRITE at executing WRITE AND VERIFY

2)Application requirements

When any of the above commands is issued to LBA registered in the uncorrectable error log of the READ command (LBA log of uncorrectable error while the READ command is executed), the AWRE processing is applied.

3)AWRE processing

The following processings are performed when the LBA matches the one in the uncorrectable error log:

a)Primary media check

-Creates an uncorrectable error pattern (invalid LBA pattern) in the position of the error LBA, repeats the primary media check up to three times. If the error still occurs after the check repeated three times, it is judged to be defective. Then, it performs the alternate processing.

b)Alternate processing

-Alternate media check

Writes the data that causes an unrecoverable error into the alternate block, and performs the media check.

(If the alternate block is a defective sector, the block is registered to the G list, another alternate block is allocated.)

c)SA and defect map update processing (on alternate side)

When an error occurs in the alternate processing, this WRITE command terminates with error. When the alternate processing normally terminates, the WRITE command is executed.

C141-E219

3-13

Image 41
Contents C141-E219-01EN For Safe Operation Revision Record Related Standards Overview of Manual PrefaceConventions for Alert Messages PrefaceImportant Alert Messages Important Alert ItemsData loss Important Alert ItemsSpecifications Maintenance ManualManual Organization Product InterfaceThis page is intentionally left blank Contents Contents InstallationSense data 4-44-xx, 5-2x-xx, B-44-xx, B-47-xx, B-4B-xx Troubleshooting with disk drive replacement in the fieldTroubleshooting with parts replacement in the factory Figures Tables This page is intentionally left blank General Description Standard Features Hardware Structure System ConfigurationGeneral Description Standard FeaturesStandard Features General Description Hardware Structure System Configuration Model names and order numbers Hardware SpecificationsHardware Specifications Model name and order number Function specifications SpecificationsMAV2073RC MAV2036RC 32/34 MeeprmlHardware Specifications Environmental/Power requirements Environmental specificationsMTBF= Error rateReliability Specifications Data Space Cylinder configurationData Space Logical Data Block Addressing Defect Management Data Format Data Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements Dimensions Installation RequirementsMounting orientations Installation RequirementsMounting Requirements Mounting frame structure Connection Requirements Surface temperature check point and maximum temperatureHDC MPUService clearance area Current waveform +12V DC Power Supply RequirementsConnector location 10 SAS plug connector overview Interface connectorInterface connector SAS plug signal allocationCN1 Installation Installation Mounting Drives Mounting procedures SettingSetting Port Address Installation Formatting Installation Setting parameters Arre Awre PER AwreArre Xxxx DiscXffff Dismounting Drives Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Precautions Maintenance InformationMaintenance requirements Revision numbers Maintenance levelsIndicating revision numbers Tools and test equipment Tests Test flowchartOperation test Diagnostic testOperation Check Initial seek operation check Troubleshooting with disk drive replacement in the field Troubleshooting ProceduresSystem-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense data Error Analysis Information Collection Sense Data AnalysisILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorGlossary Target Targ GlossaryAcronyms and Abbreviations SAS Acronyms and AbbreviationsECC BcrcIndex Mode SELECT/MODE SelectMtbf Mttr PADC141-E219 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank