The current parameter(s) is (are) not allowed. Please use (an)other parameter(s) and try scanning again.

Cause:

An incorrect value has been specified for the image scanner. The

 

problem may be due to an illegal combination with the specification

 

value from the application.

User response:

Change the specification values. Then, try scanning again.

The scanner is in an irregular status; fuse is broken, etc. Please check the scanner status.

Cause:

A scanner fault such as a blown fuse or foreign matter in the scanning

 

section has occurred.

User response:

Check the scanner status. If a fuse has blown, replace the fuse. If

 

there is foreign matter in the scanning section, remove the foreign

 

matter. If the error persists, contact the retail store where the image

 

scanner was purchased or the nearest maintenance and service center.

Memory is insufficient.

Cause:

Insufficient memory for scanning. The memory available may be

 

insufficient because an application consuming much GDI memory is

 

operating, too many other programs operate at the same time, or there

 

are too many registered device drivers. The user may mistakenly

 

think that adding more memory will solve this problem. However, in

 

most cases, memory shortage is due to insufficient conventional

 

memory (called the main memory within 640 kilobytes). Checking

 

CONFIG.SYS and AUTOEXEC.BAT may be a better solution.

User response:

Cancel the registration of device drivers that are irrelevant and make

 

sure that only the absolutely necessary programs are operating. Use

 

the memory optimization tool to allocate as much conventional

 

memory as possible.

An error occurred in the temporary file.

Cause:

Accessing the internal temporary file of the scanned image is causing

 

the error. The disk space may be insufficient, the temporary file may

 

be damaged, or other programs may be affecting disk access.

User response:

Increase the free space of the disk. Check the hard disk (chkdsk and

 

scandsk). Make sure that no other program is accessing the disk. If

 

the error message persists, contact the retail store where the product

 

was purchased or the nearest service center.

Download file not found.

Cause:

A file specified as a dither pattern or gamma pattern cannot be found.

User response:

Check that the download file is in the specified directory. Otherwise,

 

use the file selection dialog to specify an available file.

66

Image 72
Contents Scanner Utility for Microsoft Windows 32bit Version Introduction Trademarks Organization Contents Appendix Characteristics of this Driver Ctrl Explanation of terms Twain Figure Twain Application Preparation Figure Fujitsu Twain group Selecting the Driver Figure Main Dialog Displaying Driver Information Setting Information on Image Scanning Figure Custom paper size setting dialog Page Page Page Page Page Specifying Driver Operation Progress indicator Setting Scanning Area Setting Options Figure Option dialog Rotation Page Figure Option dialog Job/Cache Page Page Figure Option dialog Generic Figure Option dialog Endorser Page Page Setting Advance Options Figure Advance dialog density correction Page Figure Advance dialog image processing Page Figure Advance dialog DTC Mode Page Figure Advance dialog DTC Mode IPC-3/3D and IPC-4D installed Figure Advance dialog Color Image Mode Color selected Page Figure Advance dialog Quality Image Mode Color selected Page Figure Option dialog box simplified DTC Page Page Basic Scan Dialog Page Download Pattern File Page Page Page Figure Gamma Pattern Editor Tool start-up menu File menu Help menu Gamma Pattern Editing How to Use the Fujitsu Scanner Control Center Pop-up Menu Page Setting the Start button Page Page Messages from the Twain Driver Page Page Page Page Installed Nearest maintenance service center ∙ Enter a positive decimal value Cause Messages concerning to Fujitsu Scanner Control Center Page Relevant Image Scanner Specification Page Enabled Use of Fujitsu Scanner Control Center Disabled SCSI-II SCSI-II Page SCSI-II Page SCSI-II Page SCSI-II Page SCSI-II Page SCSI-II Maintenance Service Twain Scanner/Driver Utility