Cisco Systems 3560-X manual StackPower Connector Catalyst 3750-X Switches, Management Ports

Page 30

Chapter 1 Product Overview

Rear Panel Description

The nine ports on the XPS-2200 provide the power and management signals to the Catalyst 3750-X and 3560-X switches. Other switch models do not support this management communication. The XPS-2200 communicates with each switch through the 12-pin cable. All connected switches can simultaneously communicate with the XPS-2200. You can configure these XPS-2200 features through the switch software:

Enable XPS active or standby mode for each connected switch

Configure switch priority for XPS support

List the connected switches and power supply module sizes

Report when a switch is powered by the XPS

Report the XPS power supply module status

Read and monitor backup, failure, and exception history

See the switch software configuration guide on Cisco.com:

http://www.cisco.com/en/US/products/ps10745/products_installation_and_ configuration_guides_list.html

StackPower Connector (Catalyst 3750-X Switches)

The Catalyst 3750-X switches have a StackPower connector for use with Cisco StackPower cables to configure a switch power stack that includes up to four switches. By adding an XPS-2200 expandable power system, you can configure a power stack that comprises up to nine switches. A switch power stack can be configured in redundant or power-sharing mode.

You can order these StackPower cables from your Cisco sales representative:

CAB-SPWR-30CM (0.3-meter cable)

CAB-SPWR-150CM (1.5-meter cable)

For details about connecting StackPower cables and StackPower guidelines, see the “Planning a StackPower Stack (Catalyst 3750-X Switches)” section on page 2-8.

Management Ports

Ethernet Management Port

You can connect the switch to a host such as a Windows workstation or a terminal server through the 10/100 Ethernet management port or one of the console ports (see Figure 1-5and Figure 1-6). The 10/100 Ethernet management port connection uses a RJ-45 crossover or straight-through cable. The RJ-45 console port connection uses the supplied RJ-45-to-DB-9 female cable. The USB console port uses a USB type-A-to-USB 5-pin mini-Type B cable.

Table 1-19shows the Ethernet management port LED colors and their meanings.

Table 1-19 RJ-45 Console Port LED

Color

Green

Description

Active link to PC

 

Catalyst 3750-X and 3560-X Switch Hardware Installation Guide

1-20

OL-19593-01

Image 30
Contents Americas Headquarters Text Part Number OL-19593-01Page N T E N T S Attaching the Rack-Mount Brackets Where to Go Next SFP and SFP+ Module Cable Specifications B-5 Vii Viii Catalyst 3750-X switches Catalyst 3560-X switches PurposeRelated Publications Obtaining Documentation and Submitting a Service Request Switch Models Switch Model Cisco IOS Image DescriptionSwitch Part Number Description Front Panel Description 10/100/1000 Ethernet PortsPoE+ Ports Network Modules SFP and SFP+ Modules Network Module DescriptionPart Number Description SFP-10G-LRM= SFP-10G-LR=SFP-10G-SR= SFP-H10GB-CU1M=SFP-H10GB-CU5M= LEDsSFP-H10GB-CU3M= XPS 1 LEDColor System Status System LEDPort LEDs and Modes Color XPS StatusMode LED Port Mode Description Port Mode Port LED Color MeaningUSB Console LED Stack LED Catalyst PWR LED CatalystMaster LED Catalyst ColorPoE+ LED Color PoE+ StatusG1 LED G3 LED G2/TE1 LED G4/TE2 LED USB Mini-Type B PortNetwork Module LEDs Color Network Module Link StatusCatalyst 3560-X Switch Rear Panel Rear Panel DescriptionUSB Type a Interface RS-232 console is disabled RS-232 console is enabledRJ-45 Console Port LED StackWise PortsPower Supply Modules Switch Power Supply ModulesPort Port PoE+ Non-PoE+ Power Supply Module Switch1 AC-Power Supply Module LEDs Port Port PoE+ Non-PoE+ Power Supply Module SwitchPoE Option Port Switch DC-Power Supply Module LEDsXPS Connector Fan ModulesEthernet Management Port StackPower Connector Catalyst 3750-X SwitchesManagement Ports Active link to PCOff Amber Management OptionsUSB Mini-Type B Port Inactive link Post failureNetwork Configurations Preparing for Installation Safety WarningsOL-19593-01 Installation Guidelines Statement 371-Power Cable and AC AdapterPlanning a Switch Data Stack Catalyst 3750-X Switches Tools and EquipmentData Stack Cabling Configurations Switch Data Stacking Guidelines3-meter StackWise Cables Data Stack Bandwidth and Partitioning Examples Example of a Data Stack with Half Bandwidth ConnectionsPlanning a StackPower Stack Catalyst 3750-X Switches Power On Sequence for Switch Data StacksStackPower Stacking Guidelines StackPower Cabling Configurations CAB-SPWR-150CM Part Number Cable Type LengthCAB-SPWR-30CM CAB-XPS-58CM10 StackPower Ring Topology 253397 253398 Installing the Switch StackPower Partitioning ExamplesRack-Mounting Switch Installation Installing the Switch Inch brackets, part number 23/24-inch brackets, part numberEtsi brackets, part number Attaching the Rack-Mount Brackets 18 Attaching Brackets for 19-inch RacksMounting the Switch in a Rack Mounting the Switch in a Rack Table- or Shelf-Mounting 20 Attaching the Adhesive Pads for Table- or Shelf-MountingConnecting to the StackWise Ports Catalyst 3750-X Switches After Installing the SwitchConnecting to the StackPower Ports Catalyst 3750-X Switches Connecting the StackPower Ports to the XPS-2200 Installing a Network Module in the SwitchInstalling Network Modules You need to supply a number-2 Phillips screwdriverInstalling SFP and SFP+ Modules Removing a Network ModuleInstalling an SFP Module 26 Installing an SFP Module in the Network ModuleConnecting Devices to the Ethernet Ports Removing an SFP Module10/100/1000 Ethernet Port Connections PoE+ Port ConnectionsDevice Crossover Cable Where to Go Next Start an Snmp application such as the CiscoView application Power Supply and Fan Module Installation Power Supply Module OverviewDC power supply module C3KX-PWR-715WAC=Blank cover AC OK LED AC power supply module AC power cord connectorPower cord retainer Release latchDC power supply module Grounding terminal DC OK LEDExtraction handle DC Power Supply Module LEDs Installation GuidelinesAC Power Supply Module LEDs Release handles Retainer clipsRemove the power cord from the power cord retainer Installing an AC Power SupplyTurn off the power at its source Remove the power cord from the power connectorInstalling a DC Power Supply Inserting the AC-Power Supply in the SwitchEquipment That You Need Grounding the Switch Stripping the Ground WireInstalling the DC Power Supply in the Switch See the Installation Guidelines,Wiring the DC Input Power Source 11 Inserting the DC Power Supply in the SwitchFinding the Power Supply Module Serial Number 13 DC Source a and Source B Connections with Common Ground15 715-W and 350-W AC Power Supply Module Serial Number Fan Module Overview Fan ModuleInstalling a Fan Module Finding the Fan Module Serial NumberFan LED Retainer clip Exhaust vent Extraction handles 19 Fan Module Serial Number Diagnosing Problems Switch Post ResultsSwitch LEDs Ethernet and Fiber Cables Switch ConnectionsBad or Damaged Cable Link Status10/100/1000 Port Connections PoE Port ConnectionsSFP Modules Ping End Device Switch PerformanceInterface Settings Spanning Tree LoopsResetting the Switch to the Factory Default Settings Autonegotiation and Network Interface CardsCabling Distance Finding the Switch Serial Number Switch Serial Number LocationSwitch Specifications Physical SpecificationsEnvironmental Ranges Power Supply Module Specifications C3KX-PWR-715WAC Power SpecificationsC3KX-PWR-1100WAC C3KX-PWR-350WACOperating Specification Fan Module SpecificationsPhysical Specification Airflow 60 cfmChina EMC certifications Description SpecificationMIC GostOL-19593-01 Connector Specifications 10/100/1000 PortsGigabit Ethernet CX1 SFP+ Copper Connectors Figure B-2 10-Gigabit Ethernet CX1 Copper Connector exampleFigure B-4 Simplex LC Cable Connector 10/100 Ethernet Management PortConsole Port Figure B-7 10/100 Port PinoutsCable and Adapter Specifications SFP and SFP+ Module Cable SpecificationsMMF3 GLC-T1000BASE-LX/LH GLC-LH-SMFour Twisted-Pair Cable Pinouts Two Twisted-Pair Cable PinoutsConsole Port Adapter Pinouts Switch Console RJ-45-to-DB-9 Port DTEIdentifying a Crossover Cable DeviceRxD TxD Switch Console RJ-45-to-DB-25 Port DTEGND DSR DTR CTS RTSOL-19593-01 Accessing the CLI Accessing the CLI Through Express SetupAccessing the CLI Through a Console Port Use one of these options to access the CLI RJ-45 Console PortUSB Console Port Installing the Cisco Microsoft Windows USB Device Driver ModeInstalling the Cisco Microsoft Windows XP USB Driver Installing the Cisco Microsoft Windows 2000 USB DriverUninstalling the Cisco Microsoft Windows USB Driver Using the Add or Remove Programs utilityEntering the Initial Configuration Information IP SettingsConfiguring the Setup Program Enter an enable password, and press Return These choices appear Connectors and cables Console port Connectors and cables DescribedIN-2 Port mode Post results Speed Stack StackPower StatusPower-supply module PostProduct disposal warning Connector Described LED XPSIN-6