Cisco Systems 3560-X Installing a DC Power Supply, Inserting the AC-Power Supply in the Switch

Page 69

Chapter 3 Power Supply and Fan Module Installation

Installing a DC Power Supply

Caution Do not leave the power-supply slot open for more than 90 seconds while the switch is operating.

Step 5 Insert the new power supply into the power-supply slot, and gently push it into the slot (Figure 3-6). When correctly inserted, the 350-W and 715-W power supplies (excluding the power cord retainer) are flush with the switch rear panel. The 1100-W power-supply module extends 1.5 inches from the switch rear panel.

Figure 3-6 Inserting the AC-Power Supply in the Switch

CONSOLE

AUX

STACK 1

RESET

 

STACK 2

S-PWR

XPS

S-PWR

AC OK

 

 

PS

 

C3

OK

 

 

 

KX-PWR-

 

 

715WAC

AC OK

 

 

PS

OK

C3

 

 

KX-PWR-

 

 

715WAC

253159

Step 6 (Optional) Make a loop in the power cord and thread it through the power cord retainer (Figure 3-7).

Figure 3-7 AC-Power Supply with Power Cord Retainer

 

-715WAC

C3KX

-PWR

PS OK

 

AC OK

 

-715WAC

C3KX

-PWR

PS OK

 

AC OK

253160

Step 7 Connect the power cord to the power supply and to an AC power outlet. Turn on the power at the power source.

Step 8 Confirm that the power supply AC OK and PS OK LEDs are green. See Table 1-18for a description of the power supply module LEDs.

Installing a DC Power Supply

Equipment That You Need, page 3-8

Grounding the Switch, page 3-9

Installing the DC Power Supply in the Switch, page 3-10

Wiring the DC Input Power Source, page 3-11

Catalyst 3750-X and 3560-X Switch Hardware Installation Guide

 

OL-19593-01

3-7

 

 

 

Image 69
Contents Text Part Number OL-19593-01 Americas HeadquartersPage N T E N T S Attaching the Rack-Mount Brackets Where to Go Next SFP and SFP+ Module Cable Specifications B-5 Vii Viii Catalyst 3750-X switches Catalyst 3560-X switches PurposeRelated Publications Obtaining Documentation and Submitting a Service Request Switch Model Cisco IOS Image Description Switch ModelsSwitch Part Number Description Front Panel Description 10/100/1000 Ethernet PortsPoE+ Ports Network Modules Network Module Description SFP and SFP+ ModulesPart Number Description SFP-10G-SR= SFP-10G-LR=SFP-10G-LRM= SFP-H10GB-CU1M=SFP-H10GB-CU3M= LEDsSFP-H10GB-CU5M= XPS 1 LEDPort LEDs and Modes System LEDColor System Status Color XPS StatusPort Mode Port LED Color Meaning Mode LED Port Mode DescriptionUSB Console LED Master LED Catalyst PWR LED CatalystStack LED Catalyst ColorColor PoE+ Status PoE+ LEDNetwork Module LEDs USB Mini-Type B PortG1 LED G3 LED G2/TE1 LED G4/TE2 LED Color Network Module Link StatusRear Panel Description Catalyst 3560-X Switch Rear PanelRJ-45 Console Port LED RS-232 console is disabled RS-232 console is enabledUSB Type a Interface StackWise PortsPower Supply Modules Switch Power Supply ModulesPort Port PoE+ Non-PoE+ Power Supply Module Switch1 PoE Option Port Switch Port Port PoE+ Non-PoE+ Power Supply Module SwitchAC-Power Supply Module LEDs DC-Power Supply Module LEDsFan Modules XPS ConnectorManagement Ports StackPower Connector Catalyst 3750-X SwitchesEthernet Management Port Active link to PCUSB Mini-Type B Port Management OptionsOff Amber Inactive link Post failureNetwork Configurations Safety Warnings Preparing for InstallationOL-19593-01 Statement 371-Power Cable and AC Adapter Installation GuidelinesTools and Equipment Planning a Switch Data Stack Catalyst 3750-X SwitchesSwitch Data Stacking Guidelines Data Stack Cabling Configurations3-meter StackWise Cables Example of a Data Stack with Half Bandwidth Connections Data Stack Bandwidth and Partitioning ExamplesPlanning a StackPower Stack Catalyst 3750-X Switches Power On Sequence for Switch Data StacksStackPower Stacking Guidelines StackPower Cabling Configurations CAB-SPWR-30CM Part Number Cable Type LengthCAB-SPWR-150CM CAB-XPS-58CM10 StackPower Ring Topology 253397 253398 Installing the Switch StackPower Partitioning ExamplesRack-Mounting Switch Installation Installing the Switch Inch brackets, part number 23/24-inch brackets, part numberEtsi brackets, part number 18 Attaching Brackets for 19-inch Racks Attaching the Rack-Mount BracketsMounting the Switch in a Rack Mounting the Switch in a Rack 20 Attaching the Adhesive Pads for Table- or Shelf-Mounting Table- or Shelf-MountingAfter Installing the Switch Connecting to the StackWise Ports Catalyst 3750-X SwitchesConnecting to the StackPower Ports Catalyst 3750-X Switches Installing a Network Module in the Switch Connecting the StackPower Ports to the XPS-2200You need to supply a number-2 Phillips screwdriver Installing Network ModulesRemoving a Network Module Installing SFP and SFP+ Modules26 Installing an SFP Module in the Network Module Installing an SFP ModuleRemoving an SFP Module Connecting Devices to the Ethernet Ports10/100/1000 Ethernet Port Connections PoE+ Port ConnectionsDevice Crossover Cable Where to Go Next Start an Snmp application such as the CiscoView application Power Supply Module Overview Power Supply and Fan Module InstallationDC power supply module C3KX-PWR-715WAC=Blank cover Power cord retainer AC power supply module AC power cord connectorAC OK LED Release latchDC power supply module Grounding terminal DC OK LEDExtraction handle AC Power Supply Module LEDs Installation GuidelinesDC Power Supply Module LEDs Release handles Retainer clipsTurn off the power at its source Installing an AC Power SupplyRemove the power cord from the power cord retainer Remove the power cord from the power connectorInserting the AC-Power Supply in the Switch Installing a DC Power SupplyEquipment That You Need Stripping the Ground Wire Grounding the SwitchSee the Installation Guidelines, Installing the DC Power Supply in the Switch11 Inserting the DC Power Supply in the Switch Wiring the DC Input Power Source13 DC Source a and Source B Connections with Common Ground Finding the Power Supply Module Serial Number15 715-W and 350-W AC Power Supply Module Serial Number Fan Module Fan Module OverviewInstalling a Fan Module Finding the Fan Module Serial NumberFan LED Retainer clip Exhaust vent Extraction handles 19 Fan Module Serial Number Diagnosing Problems Switch Post ResultsSwitch LEDs Bad or Damaged Cable Switch ConnectionsEthernet and Fiber Cables Link Status10/100/1000 Port Connections PoE Port ConnectionsSFP Modules Interface Settings Switch PerformancePing End Device Spanning Tree LoopsResetting the Switch to the Factory Default Settings Autonegotiation and Network Interface CardsCabling Distance Switch Serial Number Location Finding the Switch Serial NumberSwitch Specifications Physical SpecificationsEnvironmental Ranges Power Supply Module Specifications C3KX-PWR-1100WAC Power SpecificationsC3KX-PWR-715WAC C3KX-PWR-350WACPhysical Specification Fan Module SpecificationsOperating Specification Airflow 60 cfmMIC Description SpecificationChina EMC certifications GostOL-19593-01 10/100/1000 Ports Connector SpecificationsFigure B-2 10-Gigabit Ethernet CX1 Copper Connector example Gigabit Ethernet CX1 SFP+ Copper Connectors10/100 Ethernet Management Port Figure B-4 Simplex LC Cable ConnectorFigure B-7 10/100 Port Pinouts Console PortSFP and SFP+ Module Cable Specifications Cable and Adapter Specifications1000BASE-LX/LH GLC-TMMF3 GLC-LH-SMTwo Twisted-Pair Cable Pinouts Four Twisted-Pair Cable PinoutsIdentifying a Crossover Cable Switch Console RJ-45-to-DB-9 Port DTEConsole Port Adapter Pinouts DeviceGND Switch Console RJ-45-to-DB-25 Port DTERxD TxD DSR DTR CTS RTSOL-19593-01 Accessing the CLI Accessing the CLI Through Express SetupAccessing the CLI Through a Console Port Use one of these options to access the CLI RJ-45 Console PortUSB Console Port Mode Installing the Cisco Microsoft Windows USB Device DriverInstalling the Cisco Microsoft Windows 2000 USB Driver Installing the Cisco Microsoft Windows XP USB DriverUsing the Add or Remove Programs utility Uninstalling the Cisco Microsoft Windows USB DriverEntering the Initial Configuration Information IP SettingsConfiguring the Setup Program Enter an enable password, and press Return These choices appear Console port Connectors and cables Described Connectors and cablesIN-2 Status Port mode Post results Speed Stack StackPowerPower-supply module PostProduct disposal warning XPS Connector Described LEDIN-6