Cisco Systems 3560-X, 3750-X Data Stack Cabling Configurations, Switch Data Stacking Guidelines

Page 37

Chapter 2 Switch Installation

Data Stack Cabling Configurations

Switch Data Stacking Guidelines

For general concepts and management procedures for switch stacks, see the switch software configuration guide on Cisco.com. When adding a Catalyst 3750-X switch to a Catalyst 3750 switch stack, review the Catalyst 3750-X Switch Stack Compatibility Guide on Cisco.com for information about mixed stack configurations.

Before connecting the switches in a stack, keep in mind these stacking guidelines:

Size of the switch and any optional power-supply module. The 1100-W power-supply module is longer than the other modules. Stacking switches with the same power-supply modules together makes it easier to cable the switches. For switch dimensions, see Appendix A, “Technical Specifications.”

Length of cable. Depending on the configurations that you have, you might need different-sized cables. If you do not specify the length of the StackWise cable, the 0.5-meter cable is supplied. If you need the 1-meter cable or the 3-meter cable, you can order it from your Cisco supplier. For cable part numbers, see the “StackWise Ports” section on page 1-16. The “Data Stack Cabling Configurations” section on page 2-5provides examples of recommended configurations.

For rack-mounted switch stacks connected to the XPS-2200, review this recommended sequence of events:

If you are using the XPS-2200, install the XPS first at the bottom of the stack. If needed, allow one RU space between the XPS and the first switch above to provide room for cabling.

Connect the 12-pin XPS cables to the XPS-2200.

Rack-mount the switches. If you have the optional 1100-W power-supply module, first mount the switch before installing the power-supply module.

Connect the XPS cable to the first switch above the XPS-2200. Connect the stack cables to the first switch above the XPS.

Connect the XPS cable to the second switch above the XPS-2200. Connect the stack cables to the next switch above the XPS.

Repeat until all switches are connected.

For rack-mounted switch stacks that are members of a StackPower stack as well as a data stack, see the “Planning a StackPower Stack (Catalyst 3750-X Switches)” section on page 2-8.

Data Stack Cabling Configurations

Figure 2-1is an example of a recommended configuration that uses the supplied 0.5-meter StackWise cable. In this example, the switches are stacked in a vertical rack or on a table. This configuration provides redundant connections.

Catalyst 3750-X and 3560-X Switch Hardware Installation Guide

 

OL-19593-01

2-5

 

 

 

Image 37
Contents Text Part Number OL-19593-01 Americas HeadquartersPage N T E N T S Attaching the Rack-Mount Brackets Where to Go Next SFP and SFP+ Module Cable Specifications B-5 Vii Viii Purpose Catalyst 3750-X switches Catalyst 3560-X switchesRelated Publications Obtaining Documentation and Submitting a Service Request Switch Model Cisco IOS Image Description Switch ModelsSwitch Part Number Description 10/100/1000 Ethernet Ports Front Panel DescriptionPoE+ Ports Network Modules Network Module Description SFP and SFP+ ModulesPart Number Description SFP-10G-SR= SFP-10G-LR=SFP-10G-LRM= SFP-H10GB-CU1M=SFP-H10GB-CU3M= LEDsSFP-H10GB-CU5M= XPS 1 LEDPort LEDs and Modes System LEDColor System Status Color XPS StatusPort Mode Port LED Color Meaning Mode LED Port Mode DescriptionUSB Console LED Master LED Catalyst PWR LED CatalystStack LED Catalyst ColorColor PoE+ Status PoE+ LEDNetwork Module LEDs USB Mini-Type B PortG1 LED G3 LED G2/TE1 LED G4/TE2 LED Color Network Module Link StatusRear Panel Description Catalyst 3560-X Switch Rear PanelRJ-45 Console Port LED RS-232 console is disabled RS-232 console is enabledUSB Type a Interface StackWise PortsSwitch Power Supply Modules Power Supply ModulesPort Port PoE+ Non-PoE+ Power Supply Module Switch1 PoE Option Port Switch Port Port PoE+ Non-PoE+ Power Supply Module SwitchAC-Power Supply Module LEDs DC-Power Supply Module LEDsFan Modules XPS ConnectorManagement Ports StackPower Connector Catalyst 3750-X SwitchesEthernet Management Port Active link to PCUSB Mini-Type B Port Management OptionsOff Amber Inactive link Post failureNetwork Configurations Safety Warnings Preparing for Installation OL-19593-01 Statement 371-Power Cable and AC Adapter Installation GuidelinesTools and Equipment Planning a Switch Data Stack Catalyst 3750-X SwitchesSwitch Data Stacking Guidelines Data Stack Cabling Configurations3-meter StackWise Cables Example of a Data Stack with Half Bandwidth Connections Data Stack Bandwidth and Partitioning ExamplesPower On Sequence for Switch Data Stacks Planning a StackPower Stack Catalyst 3750-X SwitchesStackPower Stacking Guidelines StackPower Cabling Configurations CAB-SPWR-30CM Part Number Cable Type LengthCAB-SPWR-150CM CAB-XPS-58CM10 StackPower Ring Topology 253397 253398 StackPower Partitioning Examples Installing the SwitchRack-Mounting Switch Installation Installing the Switch 23/24-inch brackets, part number Inch brackets, part numberEtsi brackets, part number 18 Attaching Brackets for 19-inch Racks Attaching the Rack-Mount BracketsMounting the Switch in a Rack Mounting the Switch in a Rack 20 Attaching the Adhesive Pads for Table- or Shelf-Mounting Table- or Shelf-MountingAfter Installing the Switch Connecting to the StackWise Ports Catalyst 3750-X SwitchesConnecting to the StackPower Ports Catalyst 3750-X Switches Installing a Network Module in the Switch Connecting the StackPower Ports to the XPS-2200You need to supply a number-2 Phillips screwdriver Installing Network ModulesRemoving a Network Module Installing SFP and SFP+ Modules26 Installing an SFP Module in the Network Module Installing an SFP ModuleRemoving an SFP Module Connecting Devices to the Ethernet PortsPoE+ Port Connections 10/100/1000 Ethernet Port ConnectionsDevice Crossover Cable Where to Go Next Start an Snmp application such as the CiscoView application Power Supply Module Overview Power Supply and Fan Module InstallationC3KX-PWR-715WAC= DC power supply moduleBlank cover Power cord retainer AC power supply module AC power cord connectorAC OK LED Release latchDC OK LED DC power supply module Grounding terminalExtraction handle AC Power Supply Module LEDs Installation GuidelinesDC Power Supply Module LEDs Release handles Retainer clipsTurn off the power at its source Installing an AC Power SupplyRemove the power cord from the power cord retainer Remove the power cord from the power connectorInserting the AC-Power Supply in the Switch Installing a DC Power SupplyEquipment That You Need Stripping the Ground Wire Grounding the SwitchSee the Installation Guidelines, Installing the DC Power Supply in the Switch11 Inserting the DC Power Supply in the Switch Wiring the DC Input Power Source13 DC Source a and Source B Connections with Common Ground Finding the Power Supply Module Serial Number15 715-W and 350-W AC Power Supply Module Serial Number Fan Module Fan Module OverviewFinding the Fan Module Serial Number Installing a Fan ModuleFan LED Retainer clip Exhaust vent Extraction handles 19 Fan Module Serial Number Switch Post Results Diagnosing ProblemsSwitch LEDs Bad or Damaged Cable Switch ConnectionsEthernet and Fiber Cables Link StatusPoE Port Connections 10/100/1000 Port ConnectionsSFP Modules Interface Settings Switch PerformancePing End Device Spanning Tree LoopsAutonegotiation and Network Interface Cards Resetting the Switch to the Factory Default SettingsCabling Distance Switch Serial Number Location Finding the Switch Serial NumberPhysical Specifications Switch SpecificationsEnvironmental Ranges Power Supply Module Specifications C3KX-PWR-1100WAC Power SpecificationsC3KX-PWR-715WAC C3KX-PWR-350WACPhysical Specification Fan Module SpecificationsOperating Specification Airflow 60 cfmMIC Description SpecificationChina EMC certifications GostOL-19593-01 10/100/1000 Ports Connector SpecificationsFigure B-2 10-Gigabit Ethernet CX1 Copper Connector example Gigabit Ethernet CX1 SFP+ Copper Connectors10/100 Ethernet Management Port Figure B-4 Simplex LC Cable ConnectorFigure B-7 10/100 Port Pinouts Console PortSFP and SFP+ Module Cable Specifications Cable and Adapter Specifications1000BASE-LX/LH GLC-TMMF3 GLC-LH-SMTwo Twisted-Pair Cable Pinouts Four Twisted-Pair Cable PinoutsIdentifying a Crossover Cable Switch Console RJ-45-to-DB-9 Port DTEConsole Port Adapter Pinouts DeviceGND Switch Console RJ-45-to-DB-25 Port DTERxD TxD DSR DTR CTS RTSOL-19593-01 Accessing the CLI Through Express Setup Accessing the CLIAccessing the CLI Through a Console Port RJ-45 Console Port Use one of these options to access the CLIUSB Console Port Mode Installing the Cisco Microsoft Windows USB Device DriverInstalling the Cisco Microsoft Windows 2000 USB Driver Installing the Cisco Microsoft Windows XP USB DriverUsing the Add or Remove Programs utility Uninstalling the Cisco Microsoft Windows USB DriverIP Settings Entering the Initial Configuration InformationConfiguring the Setup Program Enter an enable password, and press Return These choices appear Console port Connectors and cables Described Connectors and cablesIN-2 Status Port mode Post results Speed Stack StackPowerPost Power-supply moduleProduct disposal warning XPS Connector Described LEDIN-6