Cisco Systems 3750-X, 3560-X manual Installing the DC Power Supply in the Switch

Page 72

Chapter 3 Power Supply and Fan Module Installation

Installing a DC Power Supply

Step 5 Use the ground screw to attach the single-ground lug to the switch rear panel. Use two ground screws to attach the dual-hole lug to the switch rear panel (Figure 3-10).

Step 6 Using a ratcheting torque screwdriver, torque the ground-lug screws to 60 lbf-in. (960 ozf-in.).

Step 7 Connect the other end of the grounding wire to an appropriate grounding point at your site or to the rack.

Figure 3-10 Attaching the Ground Lug and Wire Assembly

1

CONSOLE

AUX

STACK 1

RESET

STACK 2

2

OLE

AUX

STACK 1

RESET

STACK 2

253161

1

Single-ground screw and lug ring

2

Dual-ground adaptor and dual-hole lug

Installing the DC Power Supply in the Switch

See the Installation Guidelines, page 3-5.

Step 1 Turn off DC power. To ensure that power is off, change the circuit breakers to the OFF position, and tape the circuit-breaker switches in the OFF position.

Step 2 Remove the plastic safety cover from the power supply terminal blocks (Figure 3-4). If you are not replacing a DC power supply, go to Step 5.

Step 3 Use a number-2 Phillips screwdriver to remove the DC-input power wires from the power terminals. Step 4 Press the release latch at the right side of the power supply module inward, and pull the power supply out.

Step 5 Insert the power supply in the power-supply slot, and gently push it into the slot (Figure 3-11). When correctly installed, the DC power supply (excluding the extraction handle) is flush with the switch rear panel.

 

Catalyst 3750-X and 3560-X Switch Hardware Installation Guide

3-10

OL-19593-01

Image 72
Contents Americas Headquarters Text Part Number OL-19593-01Page N T E N T S Attaching the Rack-Mount Brackets Where to Go Next SFP and SFP+ Module Cable Specifications B-5 Vii Viii Catalyst 3750-X switches Catalyst 3560-X switches PurposeRelated Publications Obtaining Documentation and Submitting a Service Request Switch Models Switch Model Cisco IOS Image DescriptionSwitch Part Number Description Front Panel Description 10/100/1000 Ethernet PortsPoE+ Ports Network Modules SFP and SFP+ Modules Network Module DescriptionPart Number Description SFP-10G-LR= SFP-10G-SR=SFP-10G-LRM= SFP-H10GB-CU1M=LEDs SFP-H10GB-CU3M=SFP-H10GB-CU5M= XPS 1 LEDSystem LED Port LEDs and ModesColor System Status Color XPS StatusMode LED Port Mode Description Port Mode Port LED Color MeaningUSB Console LED PWR LED Catalyst Master LED CatalystStack LED Catalyst ColorPoE+ LED Color PoE+ StatusUSB Mini-Type B Port Network Module LEDsG1 LED G3 LED G2/TE1 LED G4/TE2 LED Color Network Module Link StatusCatalyst 3560-X Switch Rear Panel Rear Panel DescriptionRS-232 console is disabled RS-232 console is enabled RJ-45 Console Port LEDUSB Type a Interface StackWise PortsPower Supply Modules Switch Power Supply ModulesPort Port PoE+ Non-PoE+ Power Supply Module Switch1 Port Port PoE+ Non-PoE+ Power Supply Module Switch PoE Option Port SwitchAC-Power Supply Module LEDs DC-Power Supply Module LEDsXPS Connector Fan ModulesStackPower Connector Catalyst 3750-X Switches Management PortsEthernet Management Port Active link to PCManagement Options USB Mini-Type B PortOff Amber Inactive link Post failureNetwork Configurations Preparing for Installation Safety WarningsOL-19593-01 Installation Guidelines Statement 371-Power Cable and AC AdapterPlanning a Switch Data Stack Catalyst 3750-X Switches Tools and EquipmentData Stack Cabling Configurations Switch Data Stacking Guidelines3-meter StackWise Cables Data Stack Bandwidth and Partitioning Examples Example of a Data Stack with Half Bandwidth ConnectionsPlanning a StackPower Stack Catalyst 3750-X Switches Power On Sequence for Switch Data StacksStackPower Stacking Guidelines StackPower Cabling Configurations Part Number Cable Type Length CAB-SPWR-30CMCAB-SPWR-150CM CAB-XPS-58CM10 StackPower Ring Topology 253397 253398 Installing the Switch StackPower Partitioning ExamplesRack-Mounting Switch Installation Installing the Switch Inch brackets, part number 23/24-inch brackets, part numberEtsi brackets, part number Attaching the Rack-Mount Brackets 18 Attaching Brackets for 19-inch RacksMounting the Switch in a Rack Mounting the Switch in a Rack Table- or Shelf-Mounting 20 Attaching the Adhesive Pads for Table- or Shelf-MountingConnecting to the StackWise Ports Catalyst 3750-X Switches After Installing the SwitchConnecting to the StackPower Ports Catalyst 3750-X Switches Connecting the StackPower Ports to the XPS-2200 Installing a Network Module in the SwitchInstalling Network Modules You need to supply a number-2 Phillips screwdriverInstalling SFP and SFP+ Modules Removing a Network ModuleInstalling an SFP Module 26 Installing an SFP Module in the Network ModuleConnecting Devices to the Ethernet Ports Removing an SFP Module10/100/1000 Ethernet Port Connections PoE+ Port ConnectionsDevice Crossover Cable Where to Go Next Start an Snmp application such as the CiscoView application Power Supply and Fan Module Installation Power Supply Module OverviewDC power supply module C3KX-PWR-715WAC=Blank cover AC power supply module AC power cord connector Power cord retainerAC OK LED Release latchDC power supply module Grounding terminal DC OK LEDExtraction handle Installation Guidelines AC Power Supply Module LEDsDC Power Supply Module LEDs Release handles Retainer clipsInstalling an AC Power Supply Turn off the power at its sourceRemove the power cord from the power cord retainer Remove the power cord from the power connector Installing a DC Power Supply Inserting the AC-Power Supply in the SwitchEquipment That You Need Grounding the Switch Stripping the Ground WireInstalling the DC Power Supply in the Switch See the Installation Guidelines,Wiring the DC Input Power Source 11 Inserting the DC Power Supply in the SwitchFinding the Power Supply Module Serial Number 13 DC Source a and Source B Connections with Common Ground15 715-W and 350-W AC Power Supply Module Serial Number Fan Module Overview Fan ModuleInstalling a Fan Module Finding the Fan Module Serial NumberFan LED Retainer clip Exhaust vent Extraction handles 19 Fan Module Serial Number Diagnosing Problems Switch Post ResultsSwitch LEDs Switch Connections Bad or Damaged CableEthernet and Fiber Cables Link Status10/100/1000 Port Connections PoE Port ConnectionsSFP Modules Switch Performance Interface SettingsPing End Device Spanning Tree LoopsResetting the Switch to the Factory Default Settings Autonegotiation and Network Interface CardsCabling Distance Finding the Switch Serial Number Switch Serial Number LocationSwitch Specifications Physical SpecificationsEnvironmental Ranges Power Supply Module Specifications Power Specifications C3KX-PWR-1100WACC3KX-PWR-715WAC C3KX-PWR-350WACFan Module Specifications Physical SpecificationOperating Specification Airflow 60 cfmDescription Specification MICChina EMC certifications GostOL-19593-01 Connector Specifications 10/100/1000 PortsGigabit Ethernet CX1 SFP+ Copper Connectors Figure B-2 10-Gigabit Ethernet CX1 Copper Connector exampleFigure B-4 Simplex LC Cable Connector 10/100 Ethernet Management PortConsole Port Figure B-7 10/100 Port PinoutsCable and Adapter Specifications SFP and SFP+ Module Cable SpecificationsGLC-T 1000BASE-LX/LHMMF3 GLC-LH-SMFour Twisted-Pair Cable Pinouts Two Twisted-Pair Cable PinoutsSwitch Console RJ-45-to-DB-9 Port DTE Identifying a Crossover CableConsole Port Adapter Pinouts DeviceSwitch Console RJ-45-to-DB-25 Port DTE GNDRxD TxD DSR DTR CTS RTSOL-19593-01 Accessing the CLI Accessing the CLI Through Express SetupAccessing the CLI Through a Console Port Use one of these options to access the CLI RJ-45 Console PortUSB Console Port Installing the Cisco Microsoft Windows USB Device Driver ModeInstalling the Cisco Microsoft Windows XP USB Driver Installing the Cisco Microsoft Windows 2000 USB DriverUninstalling the Cisco Microsoft Windows USB Driver Using the Add or Remove Programs utilityEntering the Initial Configuration Information IP SettingsConfiguring the Setup Program Enter an enable password, and press Return These choices appear Connectors and cables Console port Connectors and cables DescribedIN-2 Port mode Post results Speed Stack StackPower StatusPower-supply module PostProduct disposal warning Connector Described LED XPSIN-6