Chapter 1 Catalyst 6500 Series Switch Chassis Overview
Catalyst
Table 1-23 Catalyst 6513-E Switch Features (continued)
Feature
Modules
Description
•Chassis supports up to 12 Catalyst 6500 series modules.
•Some Catalyst 6500 series modules:
–Are not supported
–Require that you install a specific supervisor engine
–Have chassis slot restrictions
–Require a specific software release level
Note Check your software release notes for specific information on module support and restrictions.
Table
Item | Specification |
|
|
Environmental |
|
Temperature, operating | Certified for operation: 32° to 104°F (0° to 40°C) |
| Designed and tested for operation: 32° to 130°F (0° to 55°C) |
| Note The Catalyst 6500 series switches are equipped with internal air |
| temperature sensors that are triggered at 104°F (40°C) generating a |
| minor alarm and at 131°F (55°C) generating a major alarm. |
Temperature, nonoperating | |
and storage |
|
Thermal transition | 0.5°C per minute (hot to cold) |
| 0.33°C per minute (cold to hot) |
Humidity (RH), ambient | 10% to 90% |
(noncondensing) operating |
|
Humidity (RH), ambient | 5% to 95% |
(noncondensing) |
|
nonoperating and storage |
|
Altitude, operating | Certified for operation: 0 to 6500 feet (0 to 2000 m) |
| Designed and tested for operation: |
|
|
Catalyst 6500 Series Ethernet Modules Installation Guide
|
| |
|