Cisco Systems 6500 manual ESD Precautions, Attaching Your ESD Grounding Strap

Page 241

A P P E N D I X C

ESD Precautions

Revised: July 2011

This appendix provides information on preventing ESD when removing and installing modules in a chassis.

Attaching Your ESD Grounding Strap

Electrostatic discharge (ESD) damage, which can occur when modules or other FRUs are improperly handled, results in intermittent or complete failures. Modules consist of printed circuit boards that are fixed in metal carriers. Electromagnetic interference (EMI) shielding and connectors are integral components of the carrier. Although the metal carrier helps to protect the board from ESD, always use an ESD grounding strap when handling modules.

For preventing ESD damage, follow these guidelines:

Always use an ESD wrist strap and ensure that it makes maximum contact with bare skin. ESD grounding straps are available with banana plugs, metal spring clips, or alligator clips. All Catalyst 6500 series chassis are equipped with a banana plug connector (identified by the ground symbol next to the connector) somewhere on the front panel.

If you have an older Catalyst 6500 series chassis equipped with a plastic banana plug connector, we recommend that you use either the supplied ESD grounding wrist strap (with a metal clip) or an ESD grounding wrist strap equipped with an alligator clip.

If you have a newer Catalyst 6500 series chassis that has a bare metal hole as the banana plug connector (also identified by the ground symbol next to the hole), we recommend that you use a personal ESD grounding strap equipped with a banana plug.

If you choose to use the disposable ESD wrist strap supplied with most FRUs or an ESD wrist strap equipped with an alligator clip, you must attach the system ground lug to the chassis in order to provide a proper grounding point for the ESD wrist strap.

Note This system ground is also referred to as the network equipment building system (NEBS) ground.

If your chassis does not have the NEBS system ground attached, you must install the system ground lug and a ground wire. Refer to the online Catalyst 6500 Series Switches Installation Guide for the procedure.

Catalyst 6500 Series Ethernet Modules Installation Guide

 

OL-6265-04

C-1

 

Image 241
Contents Americas Headquarters Catalyst 6500 Series Ethernet Modules Installation GuidePage Iii N T E N T SSafety Attaching Your ESD Grounding Strap C-1 OL-6265-04 Organization AudienceChapter Title Description Convention Description ConventionsVii Screen fontViii Statement 1071-Warning DefinitionAvvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseAviso Instruções Importantes DE Segurança Spara Dessa Anvisningar GEM Disse Anvisninger Xii Xiii Related DocumentationXiv Obtaining Documentation and Submitting a Service RequestCatalyst 6500 Series Switch Chassis Overview Modules Catalyst 6503 SwitchCatalyst 6500 Series Switches Installation Guide Feature DescriptionFeature Description Chassis may be placed side-by-side SpecificationCatalyst 6503-E Switch-Front View Catalyst 6503-E SwitchCatalyst 6503-E Switch Features Feature Description WS-C6503-E-FAN-282 CFM Power Supply 2 redundant Catalyst 6504-E SwitchRedundant or nonredundant mode Feature Description FAN-MOD-4HS-300 CFM Supervisor engine Redundant supervisor engine Catalyst 6506 SwitchHigh-speed fan tray Feature DescriptionsFeature Descriptions Feature WS-C6K-6SLOT-FAN Standard fan tray-227 CFM Fan assembly Supervisor engine Redundant supervisor engine Catalyst 6506-E SwitchOperate Feature Descriptions WS-C6506-E-FAN-564 CFM Supervisor engine Catalyst 6509 SwitchBay Feature Description Feature WS-C6K-9SLOT-FAN Standard fan tray-340 CFM 10 Catalyst 6509-E Switch Catalyst 6509-E Switch13 Catalyst 6509-E Switch Features Feature Description WS-C6509-E-FAN-846 CFM Redundant ESD ground strap Connection Catalyst 6509-NEB SwitchFeature Features Feature Features WS-C6509-NEB-FAN standard fan tray-294 CFM Power supply Redundant Catalyst 6509-NEB-A SwitchNonredundant mode OL-6265-04 FAN-MOD-09 high-speed fan tray-760 CFM ESD ground strap connection Catalyst 6509-V-E Switch19 Catalyst 6509-V-E Switch Features Feature Description WS-C6509-V-E-FAN High-speed fan tray-760 CFM 14 Catalyst 6513 Switch Catalyst 6513 Switch8700 W AC-input power supply is limited to 6000 W when it is Feature Description Feature WS-C6K-13SLOT-FAN standard fan tray-641 CFM Power supply Power supply 2 redundant Catalyst 6513-E SwitchCatalyst 6513-E Switch Features Feature Description 23 Catalyst 6513-E Switch Features WS-C6513-E-FAN-1755 CFM OL-6265-04 10/100 Fiber-Based Ethernet Modules Ethernet Switching ModulesMT-RJ WS-X6024-10FL-MT Ethernet ModuleStatus Environment WS-X6148-FE-SFP Ethernet ModuleLlationguideslist.html WS-X6148-FE-SFP Physical and Environmental Specifications WS-X6324-100FX-MM and WS-X6324-100FX-SM Ethernet Modules Feature Description Does not come online WS-X6524-100FX-MM Ethernet Module WS-X6524-100FX-MM Switching Modules Front PanelSee the Catalyst 6500 Series DFC, DFC3A, DFC3B, and DFC3BXL WS-X6524-100FX-MM Physical and Environmental Specifications 10/100 and 10/100/1000 Ethernet Modules Module Description WS-X6148-GE-TX and WS-X6148A-GE-TX Ethernet Modules10 WS-X6148-GE-TX and WS-X6148A-GE-TX Features Field-Upgrade Installation Note for field upgrade procedures Phone Specification WS-X6148-RJ21 Ethernet Modules WS-X6148-RJ-21 Ethernet Modules Features Through factory advance replacement only the Ieee 802.3af WS-X6148-RJ-21 Physical and Environmental Specifications WS-X6148-RJ-45 Ethernet Module Front Panel WS-X6148-RJ-45 and WS-X6148A-RJ-45 Ethernet ModulesFeature Description Distributed forwarding Not supported Support Orange-The module is booting or running diagnostics Specification Environment WS-X6148E-GE-45AT Ethernet Module Front Panel WS-X6148E-GE-45AT Ethernet ModuleStatus Specification 10 WS-F6K-48X2-SPLTR Splitter Panel WS-X6148X2-RJ-45 and WS-X6148X2-45AF Ethernet ModulesFeature Description Feature Description TDR support Not supported Module front panel LEDs WS-X6148X2-RJ-45 Physical and Environmental Specifications WS-X6196-RJ-21 and WS-X6196-21AF Ethernet Modules Distributed forwarding Not supported Support Status Specification WS-X6348-RJ21V Ethernet Module 12 WS-X6348-RJ21V Switching Module Front Panel26 WS-X6348-RJ21V Features WS-X6348-RJ45 and WS-X6348-RJ45V Ethernet Modules Feature Description Status Specification 14 WS-X6516-GE-TX Ethernet Module Front Panel WS-X6516-GE-TX Ethernet ModuleVerify that all Link LEDs are functioning Specification 33 WS-X6548-GE-TX Ethernet Module Variants Daughter Cards Field-Upgrade Installation Note for field Status Specification 16 WS-X6548-RJ-21 Ethernet Module Front Panel WS-X6548-RJ-21 Ethernet ModuleProcedures 37 WS-X6548-RJ-21 Physical and Environmental Specifications WS-X6548-RJ-45 Ethernet Module 17 WS-X6548-RJ-45 Switching Module Front PanelPluggable transceivers Not supported Support 38 WS-X6548-RJ-45 Features Environment WS-X6748-GE-TX and WS-X6848-TX-2T/-2TXL Ethernet Modules DFC3BXL Installation Note or the Catalyst 6500 Series Module is initializing Specification Specification Environment WS-X6408A-GBIC Gigabit Ethernet ModulesInformation on the Gbic transceivers WS-X6408A-GBIC Physical and Environmental Specifications WS-X6416-GBIC 44 WS-X6416-GBIC Features Specification WS-X6516-GBIC and WS-X6516A-GBIC Refer to the Catalyst 6500 Series DFC, DFC3A, DFC3B, Specification Specification Environment WS-X6724-SFP and WS-X6824-SFP-2T/-2TXL Catalyst 6500 Series Ethernet Modules Installation Guide Information on the SFP transceivers Specification Specification WS-X6748-SFP and WS-X6848-SFP-2T/-2TXL Devicesupporttableslist.html Feature Description Status Specification Specification WS-X6816-GBIC Transceivers section on page B-3in Appendix B for additional WS-X6816-GBIC Ethernet Module Features 11.2 lb 5.08 kg 25 WS-X6704-10GE Ethernet Module Front Panel WS-X6704-10GE Ethernet ModuleGB Transceivers section on page B-8 in Appendix B for Status Specification Environment WS-X6708-10G-3C and WS-X6708-10G-3CXL Ethernet Modules Feature Description 100 101 102 WS-X6716-10GE and WS-X6816-10G-2T/-2TXL Ethernet Modules103 104 105 106 107 108 WS-X6716-10T and WS-X6816-10T-2T/-2TXL Ethernet Modules109 110 111 112 113 114 WS-X6908-10G Ethernet Module115 116 117 118 WS-X6904-40G Ethernet Module119 120 121 Slot 1, 2, 3122 Safety Installing Ethernet Switching ModulesRequired Tools Installing an Ethernet Switching ModuleInstalling an Ethernet Switching Module Insert module Between slot guides EMI gasket Chassis with horizontal slotsClearing the EMI Gasket in a Horizontal Slot Chassis WS-X6K-SUP2-2GE SUPERVISOR2 Chassis with vertical slotsPositioning the Module in a Vertical Slot Chassis Clearing the EMI Gasket in a Vertical Slot Chassis Closing the Ejector Levers in a Vertical Slot Chassis Horizontal slots Removing an Ethernet Switching ModuleVertical slots Transceiver Type Installation Procedure Document and Link Installing Pluggable TransceiversAttaching Optical Network Interface Cables Attaching the Network Interface CablesMode-Conditioning Patch Cord RX TX Connecting Transceivers to a Copper Network Verifying the InstallationConsole show module Verifying Newly Installed ModulesChecking Connectivity Task CommandOL-6265-04 PoE Daughter Cards Module Power per Port WattsPoE Daughter Card Description MaximumWS-F6K-VPWR-GE= Centralized and Distributed Forwarding Daughter Cards Description Modules supported on Memory Power Card RequiredWS-F6700-DFC3BXL WS-F6K-DFC4-AXL Model Supervisor EngineMB Transceivers Pluggable Transceiver ModulesMB SFP Transceiver Transmit dBm Receive dBm Product Number 6523 Miles Mb Fast Ethernet 80 km PortsGB Transceivers Transceiver Type Illustrations Specification TablesGB Transceiver Figure B-2 1000BASE-T Gbic Transceiver WS-G5483 GB Gbic TransceiversGB Gbic Transceiver Transmit dBm Receive dBm Product Number Gbic Transceiver Interface Nominal Network Fiber CoreClasp GB SFP TransceiversGB SFP Transceiver Transmit dBm Receive dBm Product Number GLC-ZX-SM=GB Transceiver Type Supported on these Modules Figure B-6 10-Gigabit Xenpack Transceiver Xenpak TransceiversXenpak Transmit dBm Receive dBm Product Number Cisco part number X2 TransceiversFigure B-8 10-GB X2 Transceiver Fiber 24.84 mi 40 km Type Microns Bandwidth Distance1 MHz/kmSFP+ Transceivers WDM Transceivers Gigabit TransceiversWDM Transceiver Description Supported on these Type Modules1 Transceiver Specification IllustrationWDM Figure B-9 Cwdm Gbic Transceiver Model NumberDescription ITU Channel Product Number Dwdm GbicDwdm Xenpak DWDM-XENPAK-54.13 DWDM-XENPAK-34.25 OL-6265-04 Attaching Your ESD Grounding Strap ESD PrecautionsCatalyst 6500 Series Ethernet Modules Installation Guide Clip OL-6265-04 IN-1 NumericsIN-2 IN-3 IN-4 IN-5 Filler plate, moduleIN-6 IN-7 IN-8 IN-9 WS-X6148-FE-SFPIN-10 IN-11 IN-12 IN-13 WS-X6548V-GE-TXIN-14 IN-15 IN-16 IN-17 IN-18
Related manuals
Manual 20 pages 62.17 Kb Manual 160 pages 24.26 Kb Manual 112 pages 18.84 Kb