CONNECTING TO THE NETWORK
To connect twisted pair segments to the SEHI:
1.Insert the RJ45 connector from each twisted pair segment into the desired network port on the SEHI. See Figure
18X
6X
17X
5X
16X
4X
15X
3X
14X
2X
13X
1X
EPIM-2
LNK
LNK
Figure 4-1. SEHI-22/24 Network Ports
2.Check that the applicable LNK LED for the port is on. If the LED is not on, perform each of the following steps until it is:
a.Check that the 10BASE-T device at the other end of the twisted pair segment is powered up.
b.Verify that the RJ45 connector on the twisted pair segment has the proper pinouts. Check the cable for continuity.
c.Check that the twisted pair connection meets dB loss and cable specifications outlined Chapter 2.
If a link still has not been established, contact Cabletron Systems Technical Support.