Cabling and Installing the AAPs

NOTE: The online Connectivity Configurator, available at

www.extron.com, offers guidance as to the fit of AAPs into this space.

The various Extron single space and double space AAP devices, including the various RGB 580xi AAPs, can be mounted to the HSA 822. See “Reference Information” for RGB 580xi AAP part numbers.

The screws for installing an AAP are built into its AAP panel, so no additional screws are needed.

WARNING: Ensure that AC power is disconnected before servicing the HSA unit.

1.Remove the top and bottom screws on the right and left sides of the AAP panel (see figure 6). Retain the screws. Lift the panel away from the enclosure as far as the connected cables allow and then allow the panel to dangle, supported by its connected cables.

NOTES: • The center screws on each side of the AAP panel do

not fasten the AAP panel in place. They secure the AC power outlet.

Ensure that the edges of the AAP panels do not scratch the finished surface of the top panel flange when removing the panels.

Remove two screws each side.

Remove panel.

HSA

 

822

Replacement Faceplate

Screws (4) Under Enclosure

Figure 6. Removing the AAP Panel from an HSA 822

2.Cable the rear of the AAPs before fastening the AAPs to the AAP panel. Route the cables through the hole in the underside of the surface mount enclosure and connect them to the rear of the AAPs. If applicable, refer to the cabling information in the documentation for the AAP.

3.Insert each of the AAP screws through the holes in the AAP opening of the HSA AAP panel. Secure each AAP to the panel with the provided captive washers and #4-40 nuts (see figure 7).

#4-40 Nut w/ Captive Washer

AAP Panel

Cable

INPUT

 

HSA

822

SELECT

COMPUTERAUDIO

 

 

 

 

RGB 580xi SI AAP

Figure 7. Mounting an AAP Device on the AAP Panel

4.Replace the AAP panel in the surface mount enclosure and secure it in place with the screws removed in step 1. If you lose an AAP panel screw, four spare screws are stored in the underside of the enclosure.

10 HSA 822 Hideaway Enclosure • Installation

HSA 822 Hideaway Enclosure • Installation 11

Image 10
Contents User Guide Extron Warranty 安全须知 中文 Contents Introduction About the HSA 822 Hideaway EnclosureFeatures HSA 822 and RGB 580xi ConfigurationInstallation Installation OverviewPreparing the Routing Template Preparing the Table and Mounting the EnclosureCutting the Opening with a Router Cabling and Installing the AAPs RGB 580xi SI AAPBottom Panel Features Cabling the EnclosureRouting the AAP Cables BezelsMaintenance Modifications Replacing an AAPReplacing the Bezels Removing the AAP PanelRemoving and Replacing the Enclosure Replacing the Gas Lift Removing the HSA 822 from the TableTop Panel Bracket Frame Clevis Nut Adjusting the Top Surface Adjusting the Height of the Top SurfaceSpecifications Reference InformationTop Plate Dimensions Template, Replacement Parts, and AccessoriesInterface Accessories Part NumbersPackaging for Shipment HSAAttaching the Clamshell HSA Suspended in the Foam