Extron electronic HSA 822 manual Top Panel Bracket Frame Clevis Nut

Page 17

4.Open and close the top panel as necessary to access the center lifting platform (see figure 17). Remove the four screws that secure the top panel bracket to the lifting platform.

Top Panel

Bracket

Frame

Clevis Nut

Top Panel

 

Clevis

Gas Lift

Lifting

Platform

Enclosure

Frame

Figure 17. Changing the Gas Lift

CAUTION: With the top panel bracket detached from the lifting platform, the bracket will be loose atop the gas lift. Ensure that the bracket does not contact the top flange. Marring of the soft surface of the flange may result.

5.Turn the enclosure frame rightside-up.

6.Remove and retain the 9/32-inch nut and bolt that secure the gas lift to the top panel clevis. Lift the top panel and clevis off of the gas lift and set it aside on the bracket flanges.

7.Turn the gas lift counterclockwise until the lift comes free of the frame clevis nut at the bottom of the enclosure frame. Carefully draw the gas lift out through the top of the enclosure frame.

8.Insert the shaft end of the replacement gas lift through the hole in the lifting platform. Thread the shaft of the gas lift into the frame clevis nut and tighten it several turns.

CAUTION: Ensure that the top panel bracket does not contact the top flange. Marring of the soft surface of the flange may result.

9.Hold the top panel in position above the gas lift. Secure the gas lift to the top panel clevis with the nut and bolt that were removed in step 6.

10.Reconnect the interior AC power cables.

11.If necessary, release (extend) the top panel. Turn the enclosure frame upside-down and place it on the soft cloth surface.

12.Secure the top panel bracket to the lifting platform with the four screws removed in step 4.

13.Reinstall the surface mount enclosure. See “Removing and Replacing the Enclosure”, steps 11 through 18.

24 HSA 822 Hideaway Enclosure • Maintenance and Modifications

HSA 822 Hideaway Enclosure • Maintenance and Modifications 25

Image 17
Contents User Guide Extron Warranty 安全须知 中文 Contents About the HSA 822 Hideaway Enclosure IntroductionHSA 822 and RGB 580xi Configuration FeaturesInstallation Overview InstallationPreparing the Table and Mounting the Enclosure Preparing the Routing TemplateCutting the Opening with a Router RGB 580xi SI AAP Cabling and Installing the AAPsCabling the Enclosure Bottom Panel FeaturesBezels Routing the AAP CablesReplacing an AAP Maintenance ModificationsRemoving the AAP Panel Replacing the BezelsRemoving and Replacing the Enclosure Removing the HSA 822 from the Table Replacing the Gas LiftTop Panel Bracket Frame Clevis Nut Adjusting the Height of the Top Surface Adjusting the Top SurfaceReference Information SpecificationsInterface Accessories Template, Replacement Parts, and AccessoriesTop Plate Dimensions Part NumbersHSA Packaging for ShipmentAttaching the Clamshell HSA Suspended in the Foam