Extron electronic HSA 822 manual Preparing the Routing Template

Page 8

Preparing the Routing Template

Extron offers a metal routing template for the HSA 822,

part number 70-191-01. Extron recommends using this template as a guide to cut the hole in the table where the HSA will be installed.

NOTE: The metal routing template is reusable. Save it for future HSA 822 installations.

1.Cut 1/2-inch x 4-inch strips of soft, finished lumber long enough to span the distance between the desired installation location on the table or other mounting surface and the edges of the table (see figure 3).

Mounting

Surface

Edge

Minimum

Wood

4 Screws

Strips

Wood Strip Height

4" / 10.2 cm

Mounting

Routing Template

Surface

 

Edge

 

Wood Thickness 0.5" / 1.3 cm

Figure 3. Prepared Routing Template

These strips raise the routing template above the mounting surface to provide room for the collar of the router, protect the mounting surface, and extend the reach of the routing template so that it can be clamped to the edge of the surface.

2.Using four or more short wood screws, secure the routing template to the lumber strips.

CAUTION: Do not allow the wood screws to protrude through the bottom of the wooden strips. Protruding screws will mar the table when the template is used.

Preparing the Table and Mounting the Enclosure

The preferred and recommended method for preparing the table is to use the appropriate Extron metal routing template and a router.

Alternatively, you can use a paper cut-out template (see “Reference Information”) and a sabre saw or keyhole saw, but this method is not recommended.

Prepare the table as follows:

CAUTIONS: • The opening in the table for the HSA 822 should be cut only by licensed and bonded craftspeople. Exercise care to prevent scarring or damaging the furniture.

The routing templates for the various HSA models are not interchangeable. If you use the wrong template, you will cut an improperly-sized hole. If you use a larger template than required, the cut will result in gaps in the table surface on either side of the enclosure.

The surfaces of the HSA enclosure have screws and other protruding hardware that could damage fine furniture. Do not rest the enclosure on unprotected furniture.

NOTE: The metal routing template is reusable. Save it for future HSA 822 installations.

1.Locate the desired mounting location on the tabletop or other installation surface. Mark the location.

CAUTION: Ensure that only the wooden strips contact the furniture. Failure to do so may mar the furniture.

2.Place the routing template assembly on the table, centered on the mounting location. Angle the template for the optimum positioning. If necessary, use a square to ensure that the template is properly positioned. Extron is not responsible for improperly-positioned HSA products.

3.Once the template assembly is positioned properly, secure the assembly to the table with C-clamps (see figure 4, on the next page).

6

HSA 822 Hideaway Enclosure • Installation

HSA 822 Hideaway Enclosure • Installation

7

Image 8
Contents User Guide Extron Warranty 安全须知 中文 Contents Introduction About the HSA 822 Hideaway EnclosureFeatures HSA 822 and RGB 580xi ConfigurationInstallation Installation OverviewPreparing the Routing Template Preparing the Table and Mounting the EnclosureCutting the Opening with a Router Cabling and Installing the AAPs RGB 580xi SI AAPBottom Panel Features Cabling the EnclosureRouting the AAP Cables BezelsMaintenance Modifications Replacing an AAPReplacing the Bezels Removing the AAP PanelRemoving and Replacing the Enclosure Replacing the Gas Lift Removing the HSA 822 from the TableTop Panel Bracket Frame Clevis Nut Adjusting the Top Surface Adjusting the Height of the Top SurfaceSpecifications Reference InformationTemplate, Replacement Parts, and Accessories Interface AccessoriesTop Plate Dimensions Part NumbersPackaging for Shipment HSAAttaching the Clamshell HSA Suspended in the Foam
Related manuals
Manual 28 pages 60.55 Kb