Extron electronic HSA 822 manual Maintenance Modifications, Replacing an AAP

Page 13

Maintenance and

Modifications

This section describes modifying and maintaining the HSA 822 surface mount enclosures. Most of the maintenance procedures require removing the surface mount enclosure from the table. Topics that are covered include:

Replacing an AAP

Replacing the Bezels

Removing and Replacing the Enclosure

Replacing the Gas Lift

Adjusting the Top Surface

Replacing an AAP

Replace one or more AAPs as follows:

WARNING: Ensure that AC power is disconnected before servicing the HSA unit.

1.On the underside of the clamshell and in the enclosure, cut the tie wraps that route the AAP cables out of the way.

2.Remove the top and bottom screws on the right and left sides of the AAP panel (see figure 12 on the next page). Retain the screws. Lift the panel away from the enclosure as far as the connected cables allow and then allow the panel to dangle, supported by its connected cables.

NOTE: The center screws on each side of the AAP panel do

not fasten the AAP panel in place. They secure the AC power outlet.

CAUTION: Ensure that the edges of the AAP panels do not scratch the finished surface of the top panel flange or the furniture in which the HSA 822 is installed when removing the panels.

16 HSA 822 Hideaway Enclosure • Installation

HSA 822 Hideaway Enclosure • Maintenance and Modifications 17

Image 13
Contents User Guide Extron Warranty 安全须知 中文 Contents About the HSA 822 Hideaway Enclosure IntroductionHSA 822 and RGB 580xi Configuration FeaturesInstallation Overview InstallationPreparing the Table and Mounting the Enclosure Preparing the Routing TemplateCutting the Opening with a Router RGB 580xi SI AAP Cabling and Installing the AAPsCabling the Enclosure Bottom Panel FeaturesBezels Routing the AAP CablesReplacing an AAP Maintenance ModificationsRemoving the AAP Panel Replacing the BezelsRemoving and Replacing the Enclosure Removing the HSA 822 from the Table Replacing the Gas LiftTop Panel Bracket Frame Clevis Nut Adjusting the Height of the Top Surface Adjusting the Top SurfaceReference Information SpecificationsInterface Accessories Template, Replacement Parts, and AccessoriesTop Plate Dimensions Part NumbersHSA Packaging for ShipmentAttaching the Clamshell HSA Suspended in the Foam