Extron electronic HSA 822 manual Removing and Replacing the Enclosure

Page 15

Removing and Replacing the Enclosure

The procedures for replacing the gas lift and adjusting the levelling of the top surface require removing the HSA 822 from the table. Remove and replace the surface mount enclosure for maintenance as follows:

WARNING: Ensure that AC power is disconnected before servicing the HSA unit.

1.On the underside of the clamshell and in the enclosure, cut the tie wraps that route the AAP cables out of the way.

2.Disconnect the IEC power cord and RJ-45 connectors from the underside of the surface mount enclosure.

3.On both AAP panels, remove the top and bottom screws on the right and left sides of the AAP panel (see figure 12 on page 18). Retain the screws. Lift the panels away from the enclosure as far as the connected cables allow and then allow the panels to dangle, supported by their connected cables.

NOTE: The center screws on each side of the AAP panel do

not fasten the AAP panel in place. They secure the AC power outlet.

CAUTION: Ensure that the edges of the AAP panels do not scratch the finished surface of the top panel flange or the furniture in which the HSA 822 is installed when removing the panels.

4. To ensure that the bottom RJ-45 connectors match up with the

AAP panel RJ-45 connectors when the maintenance is complete,

tag the internal CAT 6 cables to define their installation location

CAUTIONS: • The flanged edges of the top of the surface enclosure are bevelled to an ultra-fine thickness of less than 0.04 (4/100) inch (approximately 1 mm). These edges are soft and can be easily nicked

or bent. Exercise caution when handling and mounting the enclosure. Mishandling can damage the appearance of the enclosure.

The surfaces of the HSA enclosure have screws and other protruding hardware that could damage fine furniture. Do not rest the enclosure on unprotected furniture.

8.On the underside of the table, remove the two bolts that secure the clamshell to the surface mount enclosure (see figure 15 on the next page). Lift the enclosure out of the table.

9.Remove and retain the four corners screws on each side of the enclosure shroud “cube”. Remove the two halves of the shroud.

NOTE: You do not need to remove the center screws on each

side. They do not secure the shroud in any way; rather, they provide structural support to the enclosure.

10.Perform the desired maintenance or modification procedure.

11.If the surface is not level or the top panel is not level with the flange, adjust the top surface. See “Adjusting the Top Surface” in this chapter.

12.Connect the appropriate cables to the rear of the AAPs installed on the AAP panels. Route the cables through the hole in the underside of the surface mount enclosure and connect them to the rear of the AAPs. Refer to the cabling information in the documentation for the AAP.

(top or bottom and side A or B).

Also tag the side of the enclosure itself (A or B).

5. With a Tweeker or small screwdriver, inside the

AAP panels, push down on and gently twist on the front of each RJ-45 connector detent to disconnect the connector from the rear of the AAP panel plug-in.

6.Disconnect any cables from the rear of the

existing AAPs. Carefully pull the cables through and out the bottom of the surface mount

13.Snap the interior RJ-45 cable connectors onto the rear of the RJ-45 AAP panel bezel plug-ins in the locations identified by the tags.

14.Replace the AAP panels in the surface mount enclosure and secure them in place with the screws removed in step 3. If you lose an AAP panel screw, four spare screws are stored in the underside of the enclosure.

RJ-45 Bezel

Plug-in in AAP

Panel

enclosure.

7. Set the AAP panels aside.

WARNING: The flanged edges of the top of the surface

enclosure are sharp when the HSA is removed

from the table. Exercise caution when handling to prevent personal injury.

15.Secure the two shroud halves to the enclosure frame with the eight screws per shroud half (four per side) removed in step 9. Orient the shroud halves such that the vertical column of center holes align with the column of screw inserts on the vertical slides.

16.Carefully lower the HSA enclosure into the table opening. From the underside, bolt the clamshell to the enclosure with the two bolts removed in step 8.

20 HSA 822 Hideaway Enclosure • Maintenance and Modifications

HSA 822 Hideaway Enclosure • Maintenance and Modifications 21

Image 15
Contents User Guide Extron Warranty 安全须知 中文 Contents About the HSA 822 Hideaway Enclosure IntroductionHSA 822 and RGB 580xi Configuration FeaturesInstallation Overview InstallationPreparing the Table and Mounting the Enclosure Preparing the Routing TemplateCutting the Opening with a Router RGB 580xi SI AAP Cabling and Installing the AAPsCabling the Enclosure Bottom Panel FeaturesBezels Routing the AAP CablesReplacing an AAP Maintenance ModificationsRemoving the AAP Panel Replacing the BezelsRemoving and Replacing the Enclosure Removing the HSA 822 from the Table Replacing the Gas LiftTop Panel Bracket Frame Clevis Nut Adjusting the Height of the Top Surface Adjusting the Top SurfaceReference Information SpecificationsPart Numbers Template, Replacement Parts, and AccessoriesInterface Accessories Top Plate DimensionsHSA Packaging for ShipmentAttaching the Clamshell HSA Suspended in the Foam
Related manuals
Manual 28 pages 60.55 Kb