TP Cable Termination and Recommendations

Use the following pin configurations for twisted pair cables.

Pins:

12345678

Insert Twisted

Pair Wires

RJ-45

Connector

Straight-through Cable

(for connection to a switch, hub, or router)

TIA/EIA-T568A

TIA/EIA-T568B

 

 

 

 

Pin

Wire Color

Pin

Wire Color

 

 

 

 

 

 

 

 

1

White-green

1

White-orange

 

 

 

 

2

Green

2

Orange

 

 

 

 

3

White-orange

3

White-green

 

 

 

 

4

Blue

4

Blue

 

 

 

 

5

White-blue

5

White-blue

 

 

 

 

6

Orange

6

Green

 

 

 

 

7

White-brown

7

White-brown

 

 

 

 

8

Brown

8

Brown

 

 

 

 

Figure 11. TP Cable Termination

Supported cables

The XTP T UWP 202 is compatible with shielded twisted pair (F/UTP, SF/UTP, and S/FTP) cable.

ATTENTION:

Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable to link the XTP products.

To ensure FCC Class A and CE compliance, STP cables and STP connectors are required.

Cable recommendations

Extron recommends using the following practices to achieve full transmission distances up to 330 feet (100 meters) and reduce transmission errors.

Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best performance:

XTP DTP 24/1000

Non-Plenum 1000’ (305 m) spool

22-236-03

XTP DTP 24P/1000

Plenum 1000’ (305 m) spool

22-235-03

XTP DTP 24 Plug

Package of 10

101-005-02

If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid conductor, STP cable with a minimum bandwidth of 400 MHz.

Terminate cables with shielded connectors to the TIA/EIA-T568B standard (see figure 11).

Limit the use of more than two pass-through points, which may include patch points, punch down connectors, couplers, and power injectors. If these pass-through points are required, use shielded couplers and punch down connectors.

NOTE: When using STP cable in bundles or conduits, consider the following:

Do not exceed 40% fill capacity in conduits.

Do not comb the cable for the first 20 m, where cables are straightened, aligned, and secured in tight bundles.

Loosely place cables and limit the use of tie wraps or hook and loop fasteners.

Separate twisted pair cables from AC power cables.

XTP T UWP 202 Wallplate Transmitter • Installation and Operation 12

Image 18
Contents XTP T UWP Safety Instructions FCC Class a Notice Registered TrademarksConventions Used in this Guide Specifications AvailabilitySoftware Commands NotificationsContents XTP T UWP 202 Wallplate Transmitter Contents Introduction About this GuideAbout the XTP T UWP Key Features Typical Point-to-Point Application Diagram LAN Model ShownXTP T UWP 202 Wallplate Transmitter Introduction Installation Operation Installation OverviewInstalling the Metal Junction Box or Mud Ring Cutting an Opening in the Mounting SurfaceInstalling the Mud Ring Installing the Mud Ring with Backing ClipsRear and Side Panel Connectors Installing a UL Listed Metal Junction BoxXTP output connector RS-232 and IR Over XTP connector RS-232 IR Mounting the XTP T UWP XTP T UWPFront Panel Connectors Wiring a TRS Connector for AudioSelected Hdmi Embedded Analog Audio Audio Sent Over XTP Making ConnectionsHdmi Connection Audio PresentTP Cable Termination and Recommendations Supported cablesCable recommendations Wiring the RS-232 and IR Over XTP Connector RS-232 and IR Over XTP CommunicationPower Connection Local powerRemote power Power injectorDirect power from an XTP matrix switcher Indicators OperationFactory Reset Reset ModesReset Mode Summary Mode Activation Result Purpose/Notes ModeSIS Programming Guide SIS Configuration ControlHost Device Connection Host-to-Device and Device-to-Host CommunicationError Responses Using the Command and Response Tables for SIS CommandsSymbol Definitions Command and Response Tables for SIS Commands Input CommandsAudio Configuration Commands Picture Adjustment Commands Analog Only Preset CommandsHdcp authorized device Hdmi input only Edid Commands Advanced Configuration CommandsFactory defaults Test patternXTP System Configuration Software Installing the XTP System Configuration SoftwareUsing the XTP System Configuration Software ConnectionsDisconnect Top MenuFile menu ExitUpdate Firmware Confirm Disconnect Dialog BoxHelp Help menuAbout the Software Extron WebsiteDevice Settings AV Controls panelInput/Output tab Input/Output TabImage Settings panel Input Presets panelAnalog Video tab Audio tab Input format panelAuto-input Switching panel Factory resetGeneral tab General Information section Signal Information sectionDevice Information panel Audio Information sectionTo assign Edid to selected inputs Edid MinderAssign Edid To assign Edid to all inputsSet favorite Edid Import EdidSave output Edid Edid filtersReference Information Updating Firmware with Firmware LoaderDownloading Extron Firmware Loader Installing Firmware Loader Navigating to Firmware LoaderDownloading Firmware Downloading Firmware from the Extron WebsiteInstalling Firmware with Firmware Loader Add Device... Dialog BoxMounting Template Mounting Template for 2-gang Mud RingsExtron Warranty

XTP T UWP 202 specifications

The Extron XTP T UWP 202 is a state-of-the-art, two-gang wallplate transmitter designed for seamless integration into professional AV systems. As part of the XTP system by Extron, it leverages advanced technologies to ensure high-quality signal distribution over long distances, supporting both digital and analog video formats.

One of the standout features of the XTP T UWP 202 is its ability to transmit HDMI, along with audio and control signals, through a single CATx cable. This capability significantly simplifies installation and reduces cable clutter, making it an ideal choice for modern classrooms, conference rooms, and other professional environments. The wallplate connects directly to the XTP CrossPoint matrix switchers, allowing users to take advantage of centralized signal management.

The XTP T UWP 202 supports resolutions up to 4K@60Hz, covering a broad range of applications that require high-definition video output. The device is also equipped with EDID (Extended Display Identification Data) management, which guarantees optimal signal delivery by enabling automatic communication with the receiving display.

Another important aspect of the XTP T UWP 202 is its integrative capabilities. The wallplate includes a USB input for easy access to data sources, enhancing the overall connectivity of the AV system. Additionally, it supports Control Network, allowing integration with various control systems to manage connected devices effortlessly.

The design of the XTP T UWP 202 is user-friendly, featuring an intuitive layout that ensures ease of use for operators. The robust construction and sleek aesthetic allow it to blend seamlessly into any wall, while the included customizable labeling options help identify input sources clearly.

Moreover, the XTP T UWP 202 is equipped with anti-jitter technology, which helps to maintain signal integrity and reduces the chances of video artifacts, ensuring a reliable performance.

In summary, the Extron XTP T UWP 202 combines advanced transmission technology with high-definition video support and integrative features, making it a vital component for any professional AV installation. Its user-friendly design, combined with robust functionality, positions it as an excellent choice for users looking to optimize their AV experience.