Connect the sleeve to ground (Gnd). Connecting the sleeve to a negative
By default, the audio output follows the video switch. Audio breakaway, commanded via the
Genlock connections
A genlock device (black burst generator) can be connected to the SVS 100 via the BNC connectors shown below. The genlock feature allows the SVS 100 to be synchronized with other system components for seamless vertical interval switching between sources. See Genlock and Vertical Interval Switching in this chapter.
10 | 11 |
|
| GENLOCK |
|
| IN | OUT |
OUTPUT |
| |
L 1 R |
|
|
REMOTE
12
Figure 2-6 — Control device and external sync connections
10Genlock In connector — Connect an external black burst signal to this BNC connection for genlocking the video signal in broadcast or other
11Genlock Out connector — Connect any downstream equipment that requires genlocking to this BNC connector to route the black burst signal throughout the system in broadcast or other
RS-232/RS-422 connection
12
The SVS 100 comes from the factory already configured for
SVS 100 for
Genlock and Vertical Interval Switching
For vertical interval switching (to allow clean switching between signals from several devices during the vertical blanking period of each signal), a composite sync signal can be applied at the Genlock In connector, and also passed to another device via the Genlock Out connector.
SVS 100 Installation |