Menu Controls and Navigation

Figure 3-7 on page 3-12 shows a flowchart of all the menus. Use it as a road map or guide to get to a specific one.

There are two groups of menus. There is a menu for each of the Picture Control buttons on the front panel. These are explained on page 3-12 . The larger portion of the flow diagram is a network of menus for setting up (or displaying) the System 4xi input and output configuration, and are selected from the five Menu Control buttons on the Front Panel (shown above). The text and diagrams in this section include symbols that represent these panel buttons. They are: , , , and

The Menu Control buttons are used with the LCD screen for viewing status, changing settings, and making adjustments to the System 4xi configuration.

Each menu is described later. The Menu button ( ) is the starting point.

_______ Press

 

at any time to leave a menu and return to the Select/Exit menu.

 

 

The LCD menus include "Help" symbols to indicate how to use them. An example of these symbols can be seen in the menus to the left. Their descriptions are as follows:

The arrows in the upper-right corner (® ¯ -) of the display indicate which of

the direction buttons, , may be used with this menu. These buttons allow the user to step forward, backward, or loop through menu choices.

The character " >" marks a selection point where the user may choose

between two or more options. For menus that have more than one selection point, use the button to step from one selection point to the next (and then loop back to the first).

The character "_" is the cursor position. Use or to change the display to the right of the cursor and make a different selection. When a function blinks,

that indicates a tentative decision. That is, you have displayed something,

but have not yet made the selection. Press to select and save it. If a function does not blink, it is already selected, or active.

_______ To exit a Control Menu at any time, without saving changes, press any of the

four input buttons to return to the Default menu. (If you don’t want to change input selections, press the button for the input that is already selected.)

Terms used in LCD Menus

AUD = Audio

CHL = Input channel (used in Menu #9). It includes both Audio and Video. CFG = Configuration, as in setup

H = Horizontal, as in horizontal sync

H/V = Horizontal and Vertical, as in composite sync (H and V) LD = Line-doubled output (LQ = Line-quadrupled output) RGB = Red, Green and Blue colors or video signals

RGsB = Red, Green and Blue, and the sync included with the Green signal RGBS = Red, Green and Blue, and the Sync (H and V) on a 4th line Slave = Another switcher whose output serves as an input to a System 4xi. _m = Motion - use this for video with action.

_s = Still - use this for text or still pictures (slide presentations) VID = Video

YC = S-Video, for the chrominance (C) and the luminance (Y) V = Vertical, as in vertical sync

_______ The following pages have examples for using some of the menus, as well as

details on the function of each menu. Page 3-12 (Figure 3-7) has a flowchart of the LCD menus. You may use it as a road map to go from one menu to another.

3-3

Extron • System 4xi Switcher Series • User’s Manual

Image 26
Contents System 4xiEQSeries100 Precautions Getting Started Extron System 4xi Switcher Series User’s Manual Contents Chapter Four Connecting Multiple Switchers Iii Extron System 4xi Switcher Series User’s Manual One Introduction to System Rgbs NTSC/PALSystem 4xi Features Picture Control Memory Multiple Switcher ApplicationsInternal Power Supply with Automatic Switching Universal Projector ControlSpecifications General Audio outputControl projector Configuration and Installation Rear Panel Connectors and Indicators System 4xi Rear Panel IdentificationProjector/Monitor Applications NECUser-Supplied Cables Removing the System 4xi CoverCommunications Adapters and Cables Setting the Main Controller Board for the Projector Removing the System 4xi CoverCabling a System 4xi in a Rack Audio Wiring Applications Audio Terminal ConnectionsAudio Cable Equivalent Connections Three Using Default LCD Screen System 4xi Model DifferencesMenu Controls and Navigation Terms used in LCD MenusExample of Using the Menu Controls ScreenChoices made for this VGA mode is only Video Mode Configuration Menu Select/Exit MenuHost Baudrate Menu Audio Level Configuration MenuRGB Delay Menu Sync Configuration Menu Slave Configuration MenuLD Sync Configuration Menu Information Menu Slave Switcher Input SelectionPicture Controls line doubler/line quadrupler converter Color Control Horizontal Shift ControlContrast Control Tint ControlSystem 4xiSeries LCD Menus Special Functions System ResetToggle Executive Mode 4Chapter Four Channel Sys4 Looping the System 4xi with Other SwitchersInput Channel Addressing SW8+ SW10+ Multiple SW8+/SW10+Controlling Master/Slave Switchers J1 Pins System 4 J2 Pins Host J3 Pins Slave SwitcherSystem 4xi with SW4/6 Armx Switchers Audio System 4xi with One System 8/10 Plus SwitcherSystem 10 Plus System 4xi with Multiple System 8/10 Plus Switchers System 8/10 Plus Switch Settings System 8/10 Plus Front Access Panel SwitchesProgramming the System 4xi Looping Configuration Testing the Master/Slave Communications5Chapter Five Extron System Switcher Control Software Connect the PC to the SystemExample of the first Help menu, Help Contents System 4xi HelpWindows Control Panel Examples Executive Mode Window Pull-Down MenusHelp Menu Selections include AAppendix a RS-232 Protocol Programming the System 4xi Series SwitchersRS-232 Connections Program Instruction LevelsSystem 4xi -Initiated Messages This message will vary depending on the System 4xi modelSimple Instruction Set Related TermsSimple Instruction List Character Cmd/Rsp Dec Hex FunctionSimple Instruction Examples AsciiError Codes Description Hex Switcher ResponseHex Response Result Description Selecting Inputs Using DelimitersExamples Aud/Vid Dsp/Sw Advanced Instruction Set Error Codes ERCCommand Hex Description Advanced Instruction ListHex, Decimal and Binary Examples for Converting Range Values Select Input CMD4 34hRequest Status CMD5 35h ERCChange System Settings CMD6 36h Set Slave Configuration CMD8 38hConfigure an Input Channel CMD9 39h Request Input Channel Configuration CMD10 3Ah4 Configure System CMD11 3Bh4 Request System Configuration CMD12 3Ch4 ESC, CMD12, EOTBAppendix B System 4xi Related Parts List Video Adapter Cables Projector Communication Extension Cables ConnectorsChanging the Main Fuse DocumentationLes câ bles fournis à l’utillsasteur Enlever le couvercle du Systè meCâ bler un Systè me 4xi sur un rack Entfernung der System 4xi Abdeckung Verkabelung vom System 4xi innerhalb eines Gestells Figure B-10. System 4xi Main Controller Board Extrons Warranty Extron ELECTRONICS, Europe