Extron electronic 4LQXI, 4LDXI manual Configuration and Installation

Page 15

System 4xi Switcher Series

User’s Manual

Chapter2Two

Configuration and Installation

Rear Panel Connectors and Indicators

Projector/Monitor Applications

Removing the Cover

Setting the Main Controller Board

Rack Mounting

Audio Connections

Connecting to Projectors/Monitors

Image 15
Contents System 4xiEQSeries100 Precautions Getting Started Extron System 4xi Switcher Series User’s Manual Contents Chapter Four Connecting Multiple Switchers Iii Extron System 4xi Switcher Series User’s Manual One Rgbs NTSC/PAL Introduction to SystemSystem 4xi Features Universal Projector Control Multiple Switcher ApplicationsInternal Power Supply with Automatic Switching Picture Control MemorySpecifications Audio output Control projectorGeneral Configuration and Installation System 4xi Rear Panel Identification Rear Panel Connectors and IndicatorsNEC Projector/Monitor ApplicationsRemoving the System 4xi Cover Communications Adapters and CablesUser-Supplied Cables Removing the System 4xi Cover Setting the Main Controller Board for the ProjectorCabling a System 4xi in a Rack Audio Terminal Connections Audio Wiring ApplicationsAudio Cable Equivalent Connections Three Using System 4xi Model Differences Default LCD ScreenTerms used in LCD Menus Menu Controls and NavigationScreen Example of Using the Menu ControlsChoices made for this VGA mode is only Menu Select/Exit Menu Video Mode ConfigurationAudio Level Configuration Menu RGB Delay MenuHost Baudrate Menu Slave Configuration Menu LD Sync Configuration MenuSync Configuration Menu Slave Switcher Input Selection Picture Controls line doubler/line quadrupler converterInformation Menu Tint Control Horizontal Shift ControlContrast Control Color ControlSystem 4xiSeries LCD Menus System Reset Toggle Executive ModeSpecial Functions 4Chapter Four SW8+ SW10+ Multiple SW8+/SW10+ Looping the System 4xi with Other SwitchersInput Channel Addressing Channel Sys4J1 Pins System 4 J2 Pins Host J3 Pins Slave Switcher Controlling Master/Slave SwitchersSystem 4xi with SW4/6 Armx Switchers System 4xi with One System 8/10 Plus Switcher System 10 PlusAudio System 4xi with Multiple System 8/10 Plus Switchers System 8/10 Plus Front Access Panel Switches System 8/10 Plus Switch SettingsTesting the Master/Slave Communications Programming the System 4xi Looping Configuration5Chapter Five Connect the PC to the System Extron System Switcher Control SoftwareSystem 4xi Help Example of the first Help menu, Help ContentsWindows Control Panel Examples Window Pull-Down Menus Executive ModeHelp Menu Selections include AAppendix a Program Instruction Levels Programming the System 4xi Series SwitchersRS-232 Connections RS-232 ProtocolThis message will vary depending on the System 4xi model System 4xi -Initiated MessagesRelated Terms Simple Instruction SetCharacter Cmd/Rsp Dec Hex Function Simple Instruction ListAscii Simple Instruction ExamplesHex Switcher Response Error Codes DescriptionSelecting Inputs Using Delimiters Examples Aud/Vid Dsp/SwHex Response Result Description Advanced Instruction List Error Codes ERCCommand Hex Description Advanced Instruction SetSelect Input CMD4 34h Hex, Decimal and Binary Examples for Converting Range ValuesERC Request Status CMD5 35hSet Slave Configuration CMD8 38h Change System Settings CMD6 36hConfigure an Input Channel CMD9 39h Request Input Channel Configuration CMD10 3Ah4 Configure System CMD11 3Bh4 ESC, CMD12, EOT Request System Configuration CMD12 3Ch4BAppendix B System 4xi Related Parts List Documentation Projector Communication Extension Cables ConnectorsChanging the Main Fuse Video Adapter CablesEnlever le couvercle du Systè me Les câ bles fournis à l’utillsasteurCâ bler un Systè me 4xi sur un rack Entfernung der System 4xi Abdeckung Verkabelung vom System 4xi innerhalb eines Gestells Figure B-10. System 4xi Main Controller Board Extrons Warranty Extron ELECTRONICS, Europe