Extron electronic 4LDXI, 4LQXI Change System Settings CMD6 36h, Set Slave Configuration CMD8 38h

Page 62

Appendix A • RS-232 Programmer’s Guide

Dsp Power

80h

= Display device power is Off

 

81h

= Display device power is On

Dsp Mute

80h

= Mute Off (picture on)

 

81h

= Mute On (picture off)

Sys Pwr

80h

= System 4xi power is Off

 

81h

= System 4xi power is On

Max Chnl

80h

- 96h (maximum number of inputs on system)

Dly Time

80h

- 8Ah (RGB time delay in half seconds)

EOT

04h

= End of transmission

Response example:

1Bh, 35h, 80h, 82h, 81h, 83h, 85h, 81h, 80h, 81h, 84h, 85h, 04h Translates to:

ESC, CMD5, ERC, Video Channel #2, Audio Channel #1, S-Video mode, Hughes projector, Dsp Power is On, Dsp Mute is Off, System Power is On, Max channel # is 4, and the RGB time delay is 2.5 seconds.

Change System Settings - CMD6 (36h)

Change settings, and/or make adjustments to the system. This command allows incremental adjustments to be made to System 4xi settings, for the currently- selected input channel.

Format: ESC, CMD6, Subcom6.1, Subcom6.2, EOT

Where: ESC, CMD6 = 1Bh, 36h

Subcom6.1 = Function to adjust

80h

= Horizontal Shift

81h

= Contrast

82h

= Color

83h

= Tint (Hue)

84h

= Audio level

85h

= RGB time delay (0.5 second steps)

Subcom6.2 = How much to adjust

80h

= Adjust up 1 step

81h

= Adjust down 1 step

Example: Adjust Audio level down = 1Bh, 36h, 84h, 81h, 04h

Response: ESC, CMD6, ERC, EOT

_______ This command is optimized to be used as an audio fader control for systems

which require this feature.

Set Slave Configuration - CMD8 (38h)

Set up the System 4xi for slave configuration. The System 4xi can have another type of switcher connected to input channel 4 as a slave. In order to communicate with the slave, the System 4xi must know what type of switcher is being used.

Format: ESC, CMD8, Slave, EOT

Where: ESC, CMD8 = 1Bh, 38h

Slave

80h = No slave connected

 

84h

= SW4MX switcher connected

 

86h

= SW6MX switcher connected

 

88h

= System 8 Plus switcher connected

8Ah = System 10 Plus switcher connected 8Fh = Multiple System 8/10 Plus switchers

Response: ESC, CMD8, ERC, EOT

A-11

Extron • System 4xi Switcher Series • User’s Manual

Image 62
Contents System 4xiEQSeries100 Precautions Getting Started Extron System 4xi Switcher Series User’s Manual Contents Chapter Four Connecting Multiple Switchers Iii Extron System 4xi Switcher Series User’s Manual One Introduction to System Rgbs NTSC/PALSystem 4xi Features Picture Control Memory Multiple Switcher ApplicationsInternal Power Supply with Automatic Switching Universal Projector ControlSpecifications General Audio outputControl projector Configuration and Installation Rear Panel Connectors and Indicators System 4xi Rear Panel IdentificationProjector/Monitor Applications NECUser-Supplied Cables Removing the System 4xi CoverCommunications Adapters and Cables Setting the Main Controller Board for the Projector Removing the System 4xi CoverCabling a System 4xi in a Rack Audio Wiring Applications Audio Terminal ConnectionsAudio Cable Equivalent Connections Three Using Default LCD Screen System 4xi Model DifferencesMenu Controls and Navigation Terms used in LCD MenusExample of Using the Menu Controls ScreenChoices made for this VGA mode is only Video Mode Configuration Menu Select/Exit MenuHost Baudrate Menu Audio Level Configuration MenuRGB Delay Menu Sync Configuration Menu Slave Configuration MenuLD Sync Configuration Menu Information Menu Slave Switcher Input SelectionPicture Controls line doubler/line quadrupler converter Color Control Horizontal Shift ControlContrast Control Tint ControlSystem 4xiSeries LCD Menus Special Functions System ResetToggle Executive Mode 4Chapter Four Channel Sys4 Looping the System 4xi with Other SwitchersInput Channel Addressing SW8+ SW10+ Multiple SW8+/SW10+Controlling Master/Slave Switchers J1 Pins System 4 J2 Pins Host J3 Pins Slave SwitcherSystem 4xi with SW4/6 Armx Switchers Audio System 4xi with One System 8/10 Plus SwitcherSystem 10 Plus System 4xi with Multiple System 8/10 Plus Switchers System 8/10 Plus Switch Settings System 8/10 Plus Front Access Panel SwitchesProgramming the System 4xi Looping Configuration Testing the Master/Slave Communications5Chapter Five Extron System Switcher Control Software Connect the PC to the SystemExample of the first Help menu, Help Contents System 4xi HelpWindows Control Panel Examples Executive Mode Window Pull-Down MenusHelp Menu Selections include AAppendix a RS-232 Protocol Programming the System 4xi Series SwitchersRS-232 Connections Program Instruction LevelsSystem 4xi -Initiated Messages This message will vary depending on the System 4xi modelSimple Instruction Set Related TermsSimple Instruction List Character Cmd/Rsp Dec Hex FunctionSimple Instruction Examples AsciiError Codes Description Hex Switcher ResponseHex Response Result Description Selecting Inputs Using DelimitersExamples Aud/Vid Dsp/Sw Advanced Instruction Set Error Codes ERCCommand Hex Description Advanced Instruction ListHex, Decimal and Binary Examples for Converting Range Values Select Input CMD4 34hRequest Status CMD5 35h ERCChange System Settings CMD6 36h Set Slave Configuration CMD8 38hConfigure an Input Channel CMD9 39h Request Input Channel Configuration CMD10 3Ah4 Configure System CMD11 3Bh4 Request System Configuration CMD12 3Ch4 ESC, CMD12, EOTBAppendix B System 4xi Related Parts List Video Adapter Cables Projector Communication Extension Cables ConnectorsChanging the Main Fuse DocumentationLes câ bles fournis à l’utillsasteur Enlever le couvercle du Systè meCâ bler un Systè me 4xi sur un rack Entfernung der System 4xi Abdeckung Verkabelung vom System 4xi innerhalb eines Gestells Figure B-10. System 4xi Main Controller Board Extrons Warranty Extron ELECTRONICS, Europe