Extron electronic 4LDXI, 4LQXI manual Figure B-10. System 4xi Main Controller Board

Page 74

Appendix B • Reference

Upgrading Main Controller Board Software and Battery Replacement

________ This procedure requires removing both AC power as well as the battery backup.

If your System 4xi software is version 1.3 or greater, it may not have a backup battery. For earlier versions with a battery backup, all programs stored in the System 4xi will be lost.

1. With the System 4xi cover removed and AC power disconnected, unplug the red/ black backup battery cable at the Main Controller board. If there is no backup battery, please disregard this step.

2.Be sure you are electrically grounded! Use the PLCC IC puller to remove the old Software chip. Squeeze the tool to align the hooks with the slots provided in opposite corners of chip socket U8. Insert the hooks, squeeze gently and pull the

IC straight out of the socket. Set the chip aside.

3.Take the new software chip and note the location of the angled corner. Orient this to match the angled corner of the socket U8 and carefully press it into place.

4.For systems with a backup battery, please reconnect the red/black cable to the Main Controller board.

External Battery

l

l

Figure B-10. System 4xi Main Controller Board

_______ The new software version does not require a backup battery.

5.Reinstall the cover.

6.Connect the AC power cord and apply power to the System 4xi.

________ System 4xi Lithium Backup Battery • Danger of explosion if battery is

incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

B-7

Extron • System 4xi Switcher Series • User’s Manual

Image 74
Contents System 4xiEQSeries100 Precautions Getting Started Extron System 4xi Switcher Series User’s Manual Contents Chapter Four Connecting Multiple Switchers Iii Extron System 4xi Switcher Series User’s Manual One Introduction to System Rgbs NTSC/PALSystem 4xi Features Picture Control Memory Multiple Switcher ApplicationsInternal Power Supply with Automatic Switching Universal Projector ControlSpecifications General Audio outputControl projector Configuration and Installation Rear Panel Connectors and Indicators System 4xi Rear Panel IdentificationProjector/Monitor Applications NECUser-Supplied Cables Removing the System 4xi CoverCommunications Adapters and Cables Setting the Main Controller Board for the Projector Removing the System 4xi CoverCabling a System 4xi in a Rack Audio Wiring Applications Audio Terminal ConnectionsAudio Cable Equivalent Connections Three Using Default LCD Screen System 4xi Model DifferencesMenu Controls and Navigation Terms used in LCD MenusExample of Using the Menu Controls ScreenChoices made for this VGA mode is only Video Mode Configuration Menu Select/Exit MenuHost Baudrate Menu Audio Level Configuration MenuRGB Delay Menu Sync Configuration Menu Slave Configuration MenuLD Sync Configuration Menu Information Menu Slave Switcher Input SelectionPicture Controls line doubler/line quadrupler converter Color Control Horizontal Shift ControlContrast Control Tint ControlSystem 4xiSeries LCD Menus Special Functions System ResetToggle Executive Mode 4Chapter Four Channel Sys4 Looping the System 4xi with Other SwitchersInput Channel Addressing SW8+ SW10+ Multiple SW8+/SW10+Controlling Master/Slave Switchers J1 Pins System 4 J2 Pins Host J3 Pins Slave SwitcherSystem 4xi with SW4/6 Armx Switchers Audio System 4xi with One System 8/10 Plus SwitcherSystem 10 Plus System 4xi with Multiple System 8/10 Plus Switchers System 8/10 Plus Switch Settings System 8/10 Plus Front Access Panel SwitchesProgramming the System 4xi Looping Configuration Testing the Master/Slave Communications5Chapter Five Extron System Switcher Control Software Connect the PC to the SystemExample of the first Help menu, Help Contents System 4xi HelpWindows Control Panel Examples Executive Mode Window Pull-Down MenusHelp Menu Selections include AAppendix a RS-232 Protocol Programming the System 4xi Series SwitchersRS-232 Connections Program Instruction LevelsSystem 4xi -Initiated Messages This message will vary depending on the System 4xi modelSimple Instruction Set Related TermsSimple Instruction List Character Cmd/Rsp Dec Hex FunctionSimple Instruction Examples AsciiError Codes Description Hex Switcher ResponseHex Response Result Description Selecting Inputs Using DelimitersExamples Aud/Vid Dsp/Sw Advanced Instruction Set Error Codes ERCCommand Hex Description Advanced Instruction ListHex, Decimal and Binary Examples for Converting Range Values Select Input CMD4 34hRequest Status CMD5 35h ERCChange System Settings CMD6 36h Set Slave Configuration CMD8 38hConfigure an Input Channel CMD9 39h Request Input Channel Configuration CMD10 3Ah4 Configure System CMD11 3Bh4 Request System Configuration CMD12 3Ch4 ESC, CMD12, EOTBAppendix B System 4xi Related Parts List Video Adapter Cables Projector Communication Extension Cables ConnectorsChanging the Main Fuse DocumentationLes câ bles fournis à l’utillsasteur Enlever le couvercle du Systè meCâ bler un Systè me 4xi sur un rack Entfernung der System 4xi Abdeckung Verkabelung vom System 4xi innerhalb eines Gestells Figure B-10. System 4xi Main Controller Board Extrons Warranty Extron ELECTRONICS, Europe