Extron System Switcher Control Software

This chapter is dedicated to using Extron’s “Windows Control Program for System Switchers via RS-232” software. Extron supplies this software that runs in the Windows® operating system, version 3.1 or later (Windows95® and Windows98®). It works with several Extron system switchers, including the System 4xi series. Communication between the computer software and the switcher is established after connecting the computer to the RS-232 Port on the rear panel of the System 4xi, as follows:

1. Connect the PC’s Comm port to the RS-232 on the back of the System 4xi.

2. Power up the System 4xi and the PC and start Windows.

_______ The floppy disk has

instructions printed on the label. The software can be run from the floppy drive, or loaded onto the PC’s hard drive.

3.Install the software from the 3.5” floppy disk onto the hard disk like any other Windows application. (Run Setup.exe from

the floppy disk.)

_______ Although this

software was designed to control any System 4xi switcher, its operation will be restricted to the features and configuration of your unit.

System 4

RS-232Switcher

PC with Windows®

Operating System

Figure 5-1. Connect the PC to the System 4xi.

SYSTEM 4/8/10+

SYSTEM SWITCHER Control Pgm

4.To run the System Switcher Control program, double-click on the SYSTEM SWITCHER Control Pgm icon in the Extron Electronics group or folder. The Comm menu appears on the display.

Figure 5-2. System Switcher Control Program icon

___________

SYSTEM

SWITCHER

Help

Double-clicking the Help icon will present detailed examples of the screens and menus prior to running the Control program.

5.After you have selected the Comm Port, the software looks for the

System 4xi, “reads” its configuration, and then displays that information in a window called “Extron’s System Switcher Control program”. (see Figures 5-4 through 5-7)

5-1

Extron • System 4xi Switcher Series • User’s Manual

Image 46
Contents System 4xiEQSeries100 Precautions Getting Started Extron System 4xi Switcher Series User’s Manual Contents Chapter Four Connecting Multiple Switchers Iii Extron System 4xi Switcher Series User’s Manual One Introduction to System Rgbs NTSC/PALSystem 4xi Features Picture Control Memory Multiple Switcher ApplicationsInternal Power Supply with Automatic Switching Universal Projector ControlSpecifications Control projector Audio outputGeneral Configuration and Installation Rear Panel Connectors and Indicators System 4xi Rear Panel IdentificationProjector/Monitor Applications NECCommunications Adapters and Cables Removing the System 4xi CoverUser-Supplied Cables Setting the Main Controller Board for the Projector Removing the System 4xi CoverCabling a System 4xi in a Rack Audio Wiring Applications Audio Terminal ConnectionsAudio Cable Equivalent Connections Three Using Default LCD Screen System 4xi Model DifferencesMenu Controls and Navigation Terms used in LCD MenusExample of Using the Menu Controls ScreenChoices made for this VGA mode is only Video Mode Configuration Menu Select/Exit MenuRGB Delay Menu Audio Level Configuration MenuHost Baudrate Menu LD Sync Configuration Menu Slave Configuration MenuSync Configuration Menu Picture Controls line doubler/line quadrupler converter Slave Switcher Input SelectionInformation Menu Color Control Horizontal Shift ControlContrast Control Tint ControlSystem 4xiSeries LCD Menus Toggle Executive Mode System ResetSpecial Functions 4Chapter Four Channel Sys4 Looping the System 4xi with Other SwitchersInput Channel Addressing SW8+ SW10+ Multiple SW8+/SW10+Controlling Master/Slave Switchers J1 Pins System 4 J2 Pins Host J3 Pins Slave SwitcherSystem 4xi with SW4/6 Armx Switchers System 10 Plus System 4xi with One System 8/10 Plus SwitcherAudio System 4xi with Multiple System 8/10 Plus Switchers System 8/10 Plus Switch Settings System 8/10 Plus Front Access Panel SwitchesProgramming the System 4xi Looping Configuration Testing the Master/Slave Communications5Chapter Five Extron System Switcher Control Software Connect the PC to the SystemExample of the first Help menu, Help Contents System 4xi HelpWindows Control Panel Examples Executive Mode Window Pull-Down MenusHelp Menu Selections include AAppendix a RS-232 Protocol Programming the System 4xi Series SwitchersRS-232 Connections Program Instruction LevelsSystem 4xi -Initiated Messages This message will vary depending on the System 4xi modelSimple Instruction Set Related TermsSimple Instruction List Character Cmd/Rsp Dec Hex FunctionSimple Instruction Examples AsciiError Codes Description Hex Switcher ResponseExamples Aud/Vid Dsp/Sw Selecting Inputs Using DelimitersHex Response Result Description Advanced Instruction Set Error Codes ERCCommand Hex Description Advanced Instruction ListHex, Decimal and Binary Examples for Converting Range Values Select Input CMD4 34hRequest Status CMD5 35h ERCChange System Settings CMD6 36h Set Slave Configuration CMD8 38hConfigure an Input Channel CMD9 39h Request Input Channel Configuration CMD10 3Ah4 Configure System CMD11 3Bh4 Request System Configuration CMD12 3Ch4 ESC, CMD12, EOTBAppendix B System 4xi Related Parts List Video Adapter Cables Projector Communication Extension Cables ConnectorsChanging the Main Fuse DocumentationLes câ bles fournis à l’utillsasteur Enlever le couvercle du Systè meCâ bler un Systè me 4xi sur un rack Entfernung der System 4xi Abdeckung Verkabelung vom System 4xi innerhalb eines Gestells Figure B-10. System 4xi Main Controller Board Extrons Warranty Extron ELECTRONICS, Europe