Installation
Installation Overview
Install and set up the Cable Cubby enclosures as follows:
1If you plan to use a mounting template that has not been prepared, prepare the template. See Preparing the Routing Template, later in this chapter.
2Cut a hole in the surface where the enclosure will be installed. See Preparing the Table, later in this chapter.
3Run all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Leave enough slack in the cables to connect or route them before the cubby is installed in the table.
4If applicable, install the power module. If your location requires electrical conduit, install an Extron flexible conduit kit. Refer to the Flexible Conduit Kit Installation Guide, Extron part
5Install all desired cables into the cable
6If applicable, connect cables to the rear connectors on the passive AAPs and install the AAPs in the cubby. See Installing the AAPs, later in this chapter.
7Mount the Cable Cubby in the table. See Mounting the Cable Cubby, later in this chapter.
8Peel the protective film from the top surface.
9Connect the Cable Cubby power cord.
Preparing the Routing Template
Extron provides metal templates for the Cable Cubbies at no charge. See Routing Template Part Numbers, in appendix A, Reference Information, for part numbers. Extron recommends using this template as a guide to cut the hole in the table where the cubby will be installed.
NThe metal routing template is reusable. Do not discard this template when the installation is complete. Save it for installing Cable Cubby models of the same size.
1. | Cut 1/2" x 4" strips of soft, finished lumber at least |
| long enough to span the distance between the desired |
| installation location on the mounting surface and the edges |
| of the mounting surface (figure |
These strips raise the routing template above the mounting surface to provide room for the router’s collar, protect the mounting surface, and extend the routing template’s reach so that it can be clamped to the edge of the surface.
CDo not allow the wood screws to protrude through the bottom of the wooden strips. Protruding screws will mar the table when the template is used.
Mounting
Surface
Edge
Minimum
4 Screws
Wood
Strips
Wood Strip Height
4" / 10.2 cm
Mounting | Routing Template |
| |
Surface |
|
Edge |
|
| Wood Thickness |
| 0.5" / 1.3 cm |
| Figure |
| 2. Using four or more short wood screws, secure the |
| mounting template to the lumber strips. |
Cable Cubby® Products • Installation | Cable Cubby® Products • Installation |