Extron electronic IPL T PC1i manual Scheduling, Schedule

Page 40

Scheduling

The Schedule page accessed from the Configuration screen lets you schedule when power to the receptacle turns on and off. You can also schedule lock mode, specifying when the PC1 front panel will be locked. Clicking the Clear Schedule button at the bottom of the screen deletes all schedules. You may want to set up your schedule for a week at a time, or a day at a time.

To access the Schedule page, click Schedule on the sidebar menu on the Configuration page.

Figure 26. Schedule Page

On the Schedule page:

When you click on a day, On, Off, or the contents of any cell in the Current Schedule table (a time or a dash [-]), a Set Schedule For section displays above the Scheduling section. In this field you enter your settings for power or executive mode.

To close the Set Schedule For section without saving your entries in it, click Refresh at the bottom of the screen.

If you want to clear all power and executive mode settings from the schedule, click Clear Schedule, at the bottom of the screen.

IPL T PC1 • HTML Configuration and Control 34

Image 40
Contents IPL T PC1 IPL T PC1iAvertissement AchtungVorsicht PrecaucionFCC Class a Notice Conventions Used in this Guide Software CommandsNotifications Contents IPL T PC1 Contents Features IntroductionAbout this Guide About the IPL T PC1IPL T PC1 Introduction Application Diagram Extron IPL T PC1iInstallation Overview Installation Rear PanelThis section describes Rear Panels IPL T PC1 Rear Panel 120 VACAccessing the Communication Sheet Connecting CablesRS-232 Port Cabling Connecting the Display Device To connect the display device to the PC1Wiring for IR Control Wiring the Local Area Network LAN PortRJ-45 Connector Wiring Wiring the Contact Input Port Front Panel Features Operation Front Panel FeaturesSetting Up the System Using the Front Panel Setting Up Power Control of the Output DeviceResetting Front Panel Security Lockout Executive ModeMode ActivationResult Purpose and notesHold the Reset button in until the Power LED blinks once Purpose and notes This mode is used for troubleshootingHold the Reset button in until the Power LED blinks twice Four times in quick succession, confirming a mode 4 resetConfiguration Control Configuring the Hardware for Ethernet ControlSetting Up and Configuring the PC1 Using ARP Space must separate arp and the hyphenSetting Up and Configuring the PC1 Using a Web Browser IPL T PC1 LAN port defaultsSetting Up the Computer for IP Communication Network Connections WindowDefault gateway On the Local Area Connection Properties window, selectEnter the following values as shown below IP addressConfiguring the IPL T PC1 Using a Web Browser Internet Protocol TCP/IP Properties Window for Windows XPSystem Settings Page with Default IP Address Using the IPL T PC1 Web Pages Password Prompt WindowViewing the System Status System Status ScreenUsing the Configuration Pages Specifying system settingsIP settings Date and time settingsConfiguring the RS-232 Port and the AC Receptacle Contact input portRS-232 port Using the IR DriversAC receptacle Performing a command Assigning passwordsRemoving passwords Click SubmitEntering e-mail addresses Mail Alerts Page Upper PortionSetting up Smtp authentication Downloading the firmware from the web Upgrading FirmwareUpdating the firmware Click Browse to open a Choose file window Firmware File Selected on the Choose File WindowScheduling ScheduleScheduling output receptacle power To schedule power on and off to the output receptacleScheduling front panel lockout executive mode Set Schedule For Field for Executive ModeScheduling by day of the week Managing Files Changing an individual settingUploading files to the web Adding a directory Other file management functionsWhere x is the SIS command to be executed Custom Web PagesServer Side Includes SSIs Query stringsCode example Web Page Html Source Code Document Showing SSIsURL encoding Reserved charactersSpecial characters Reserved characters Character Hexadecimal DecimalAccessing and Using Telnet Port Unsafe charactersConnecting to the IP Address Power Connections TroubleshootingNetwork Connections Global Configurator Software Response to an Unsuccessful Ping CommandSIS Programming Control Host-to-Interface CommunicationMessages Initiated by the IPL T PC1 IPL T PC1 IP addressError Responses Password InformationError Response References Telnet Web Browser Using the Command and Response TablePort and must be hex encoded if non-alphanumeric Symbol Definitions = priority set to Send Data String command parameters X2#X2% X3#X3% X4@X4$ X4%X6$ X7@X7# X7$Command and Response Table for SIS Commands Example Mail Commands Web Browser-specific CommandsMail Server Setup Commands IP Setup CommandsSet GMT offset24 # CZ Password and Security Settings Remapping Port DesignationsFile Commands Var file new ArrayTelnet text responses Web responses Html sample codeSee below Telnet text responsesFile memory Send a page GET on port 80 followed by WSFReset Zap and Erase Commands DefaultSpecifications Reference MaterialIR control interface GeneralPart Numbers and Accessories Mounting the IPL T PC1 InterfaceRack mounting procedure Under-desk MountingMounting the IPL T PC1 Under Furniture Glossary Numbers and aMbps or 100 Mbps Device’s MAC or physical machine addressAddresses in an organization’s network Controls devicesOn and off by the PC1 10 Mbps or 100 MbpsHyperText objects from remote web pages Its corresponding physical MAC address on the LANTwo ports Standard ports used are 23 for Telnet and 80 for EthernetAre used in these commands and responses Point at which a device starts to operate at standby powerLocated, and accessed Or networks on the InternetConfiguration or provide you with feedback GlobalViewer, and your custom web pagesUSA, Canada, South America Japan Central America Europe, Africa, and the Middle China EastAsia Middle East Europe
Related manuals
Manual 2 pages 39.09 Kb Manual 27 pages 50.4 Kb

IPL T PC1, IPL T PC1i specifications

The Extron Electronics IPL T PC1 i and IPL T PC1 are advanced presentation and control processors designed for optimal efficiency in various audiovisual applications. These devices serve as integral components in many professional environments, offering sophisticated capabilities for managing and automating AV systems.

Both models feature a robust, intuitive user interface that simplifies the management of complex audiovisual setups. The IPL T PC1 i and IPL T PC1 enable seamless integration with a variety of control systems, enhancing the user experience and providing streamlined operation. With their scalable design, these devices can cater to the needs of small conference rooms to large auditoriums, making them versatile solutions for diverse applications.

One standout feature of the IPL T PC1 i is its support for Extron's GUI Designer software. This powerful tool allows users to create customized graphical user interfaces tailored to specific AV systems, ensuring that control remains user-friendly and accessible. The IPL T PC1 i also supports a wide range of communication protocols, including Ethernet, RS-232, and USB, which facilitates compatibility with multiple devices and technologies.

Both models are equipped with advanced signal processing capabilities. They offer support for high-resolution video formats, ensuring that presentations and multimedia displays maintain their quality. Options for signal routing and switching further enhance the functionality of the devices, allowing for dynamic and adaptive presentations.

The IPL T PC1 i and IPL T PC1 also feature built-in scheduling and automation capabilities. Users can program specific tasks, such as turning systems on or off, adjusting volume levels, and changing input sources, at predetermined times. This feature maximizes efficiency, minimizes the need for manual intervention, and ensures that AV systems are ready when needed.

In terms of physical design, both models are compact and rack-mountable, allowing for easy installation in equipment racks or dedicated AV cabinets. They also include comprehensive diagnostic tools for troubleshooting and system monitoring, ensuring optimal performance and reliability.

Overall, the Extron Electronics IPL T PC1 i and IPL T PC1 stand out as reliable, feature-rich solutions for managing AV systems in a variety of settings, making them a popular choice among AV professionals and institutions alike. Their blend of adaptability, user interface design, and robust signal processing capabilities positions them as leaders in the AV control market.