Extron electronic IPL T PC1i manual Global Configurator Software

Page 52

If a connection was not made, the following response appears:

Figure 41. Response to an Unsuccessful Ping Command

If you get a response indicating that the ping was unsuccessful:

a.Make sure your unit is using the appropriate subnet mask (check with your system administrator).

b.Make sure your PC does not have a software firewall program which might block the IP address of the unit.

3.If contact is established with the unit, but the unit web pages cannot be accessed by your web browser, verify (in the Options or Preferences menu) that your web browser is configured for direct network connection and not set up to use a proxy server.

If you are still experiencing problems, call the Extron S3 Sales & Technical Support Hotline.

Global Configurator Software

The Global Configurator 3 (GC 3.3) software is an alternative to using the default web pages to configure and schedule the PC1. GC 3.3 is a free asset management software that enables flexible, centralized, web-based power management for A/V systems. Using Global Configurator software, administrators can view the immediate status and power level of an output device, schedule actions such as powering on and off, monitor specified conditions, and configure its ports.

To download the latest version of Global Configurator 3 from the Extron website:

1.Select the Download tab on the Extron website home page.

2.From the sidebar menu at the left of the screen, select Software.

3.On the Download Center page, click the Download link at the right end of the Global Configurator line.

4.Fill in the required information on the next Download Center page, and click the

Download GCSWnnn.exe button (where nnn is the GC3 version number).

5.Click Run on the File Download window.

6.Follow the instructions on the subsequent screens to install GC3.3 on your computer.

For instructions on using the GC3.3 software with the PC1, see the IPL T PC1 Setup Guide, provided with the PC1, and to the Global Configuration 3.3 help program, accessible from the GC3.3 main screen.

NOTE: GC 2.3 is the minimum version required to configure the PC1.

IPL T PC1 • HTML Configuration and Control 46

Image 52
Contents IPL T PC1 IPL T PC1iAvertissement AchtungVorsicht PrecaucionFCC Class a Notice Conventions Used in this Guide Software CommandsNotifications Contents IPL T PC1 Contents Features IntroductionAbout this Guide About the IPL T PC1IPL T PC1 Introduction Application Diagram Extron IPL T PC1iInstallation Overview Installation Rear PanelThis section describes Rear Panels IPL T PC1 Rear Panel 120 VACAccessing the Communication Sheet Connecting CablesRS-232 Port Cabling Connecting the Display Device To connect the display device to the PC1Wiring for IR Control Wiring the Local Area Network LAN PortRJ-45 Connector Wiring Wiring the Contact Input Port Front Panel Features Operation Front Panel FeaturesSetting Up the System Using the Front Panel Setting Up Power Control of the Output DeviceResetting Front Panel Security Lockout Executive ModeMode ActivationResult Purpose and notesHold the Reset button in until the Power LED blinks once Purpose and notes This mode is used for troubleshootingHold the Reset button in until the Power LED blinks twice Four times in quick succession, confirming a mode 4 resetConfiguration Control Configuring the Hardware for Ethernet ControlSetting Up and Configuring the PC1 Using ARP Space must separate arp and the hyphenSetting Up and Configuring the PC1 Using a Web Browser IPL T PC1 LAN port defaultsSetting Up the Computer for IP Communication Network Connections WindowDefault gateway On the Local Area Connection Properties window, selectEnter the following values as shown below IP addressConfiguring the IPL T PC1 Using a Web Browser Internet Protocol TCP/IP Properties Window for Windows XPSystem Settings Page with Default IP Address Using the IPL T PC1 Web Pages Password Prompt WindowViewing the System Status System Status ScreenUsing the Configuration Pages Specifying system settingsIP settings Date and time settingsConfiguring the RS-232 Port and the AC Receptacle Contact input portRS-232 port Using the IR DriversAC receptacle Performing a command Assigning passwordsRemoving passwords Click SubmitEntering e-mail addresses Mail Alerts Page Upper PortionSetting up Smtp authentication Downloading the firmware from the web Upgrading FirmwareUpdating the firmware Click Browse to open a Choose file window Firmware File Selected on the Choose File WindowScheduling ScheduleScheduling output receptacle power To schedule power on and off to the output receptacleScheduling front panel lockout executive mode Set Schedule For Field for Executive ModeScheduling by day of the week Managing Files Changing an individual settingUploading files to the web Adding a directory Other file management functionsWhere x is the SIS command to be executed Custom Web PagesServer Side Includes SSIs Query stringsCode example Web Page Html Source Code Document Showing SSIsURL encoding Reserved charactersSpecial characters Reserved characters Character Hexadecimal DecimalAccessing and Using Telnet Port Unsafe charactersConnecting to the IP Address Power Connections TroubleshootingNetwork Connections Global Configurator Software Response to an Unsuccessful Ping CommandSIS Programming Control Host-to-Interface CommunicationMessages Initiated by the IPL T PC1 IPL T PC1 IP addressError Responses Password InformationError Response References Telnet Web Browser Using the Command and Response TablePort and must be hex encoded if non-alphanumeric Symbol Definitions = priority set to Send Data String command parameters X2#X2% X3#X3% X4@X4$ X4%X6$ X7@X7# X7$Command and Response Table for SIS Commands Example Mail Commands Web Browser-specific CommandsMail Server Setup Commands IP Setup CommandsSet GMT offset24 # CZ Password and Security Settings Remapping Port DesignationsFile Commands Var file new ArrayTelnet text responses Web responses Html sample codeSee below Telnet text responsesFile memory Send a page GET on port 80 followed by WSFReset Zap and Erase Commands DefaultSpecifications Reference MaterialIR control interface GeneralPart Numbers and Accessories Mounting the IPL T PC1 InterfaceRack mounting procedure Under-desk MountingMounting the IPL T PC1 Under Furniture Glossary Numbers and aMbps or 100 Mbps Device’s MAC or physical machine addressAddresses in an organization’s network Controls devicesOn and off by the PC1 10 Mbps or 100 MbpsHyperText objects from remote web pages Its corresponding physical MAC address on the LANTwo ports Standard ports used are 23 for Telnet and 80 for EthernetAre used in these commands and responses Point at which a device starts to operate at standby powerLocated, and accessed Or networks on the InternetConfiguration or provide you with feedback GlobalViewer, and your custom web pagesUSA, Canada, South America Japan Central America Europe, Africa, and the Middle China EastAsia Middle East Europe
Related manuals
Manual 2 pages 39.09 Kb Manual 27 pages 50.4 Kb

IPL T PC1, IPL T PC1i specifications

The Extron Electronics IPL T PC1 i and IPL T PC1 are advanced presentation and control processors designed for optimal efficiency in various audiovisual applications. These devices serve as integral components in many professional environments, offering sophisticated capabilities for managing and automating AV systems.

Both models feature a robust, intuitive user interface that simplifies the management of complex audiovisual setups. The IPL T PC1 i and IPL T PC1 enable seamless integration with a variety of control systems, enhancing the user experience and providing streamlined operation. With their scalable design, these devices can cater to the needs of small conference rooms to large auditoriums, making them versatile solutions for diverse applications.

One standout feature of the IPL T PC1 i is its support for Extron's GUI Designer software. This powerful tool allows users to create customized graphical user interfaces tailored to specific AV systems, ensuring that control remains user-friendly and accessible. The IPL T PC1 i also supports a wide range of communication protocols, including Ethernet, RS-232, and USB, which facilitates compatibility with multiple devices and technologies.

Both models are equipped with advanced signal processing capabilities. They offer support for high-resolution video formats, ensuring that presentations and multimedia displays maintain their quality. Options for signal routing and switching further enhance the functionality of the devices, allowing for dynamic and adaptive presentations.

The IPL T PC1 i and IPL T PC1 also feature built-in scheduling and automation capabilities. Users can program specific tasks, such as turning systems on or off, adjusting volume levels, and changing input sources, at predetermined times. This feature maximizes efficiency, minimizes the need for manual intervention, and ensures that AV systems are ready when needed.

In terms of physical design, both models are compact and rack-mountable, allowing for easy installation in equipment racks or dedicated AV cabinets. They also include comprehensive diagnostic tools for troubleshooting and system monitoring, ensuring optimal performance and reliability.

Overall, the Extron Electronics IPL T PC1 i and IPL T PC1 stand out as reliable, feature-rich solutions for managing AV systems in a variety of settings, making them a popular choice among AV professionals and institutions alike. Their blend of adaptability, user interface design, and robust signal processing capabilities positions them as leaders in the AV control market.