This section provides an overview of the Extron IPL T PC1 and IPL T PC1i IP Link® Power Control Interfaces, and describes their features features. Topics covered in this section are:

About this Guide

About the IPL T PC1

Features

Application Diagram

About this Guide

This guide contains information about the Extron IPL T PC1 and IPL T PC1i, including explanations of how to install, configure, and operate them. Unless otherwise specified, “IPL T PC1” and “PC1” refer to both product versions throughout this guide.

About the IPL T PC1

The IPL T PC1 and IPL T PC1i are Ethernet-based power management devices that can control and schedule AC power on and off. Monitoring of various device conditions is also available with Global Configurator® (GC 3.3) software. The IPL T PC1i is an international version, configured for 220 VAC with an IEC connector.

The PC1 and PC1i ports include a LAN port, a bidirectional RS-232 port, an IR output port, and a contact closure input port. These ports provide integration of power control, serial device control, IR device control, and input sensing in a single device that can be mounted on a rack or behind a display device or kiosk.

The PC1 can be a stand-alone control device or as one of many nodes in a distributed control system environment.

Features

Remote powering a device on and off — Centralized management features such as Telnet allow remote powering on and off of a plasma display, camera, video conferencing equipment, switcher, or other audio/video device. The Power button on the front panel lets you turn power on and off to the connected device, while an LED to the lower-right of the Power button lights green to indicate that the device is receiving power.

RS-232 control — The bidirectional serial port on the rear panel, along with an Extron serial driver, enables RS-232 control of an output device.

IR control — An IR port on the rear panel enables unidirectional device control via an IR emitter, supported by Extron IR drivers.

Contact closure input port — This port can detect a closed circuit between an input and ground, and trigger an event that has been set up in GC 3.3 (for example, set off an alarm, turn on a light, or notify you by e-mail that an event has occurred).

IPL T PC1 • Introduction

1

Image 7
Contents IPL T PC1i IPL T PC1Precaucion AvertissementAchtung VorsichtFCC Class a Notice Conventions Used in this Guide Software CommandsNotifications Contents IPL T PC1 Contents About the IPL T PC1 FeaturesIntroduction About this GuideIPL T PC1 Introduction Extron IPL T PC1i Application DiagramInstallation Overview Installation Rear PanelThis section describes IPL T PC1 Rear Panel 120 VAC Rear PanelsAccessing the Communication Sheet Connecting CablesRS-232 Port Cabling To connect the display device to the PC1 Connecting the Display DeviceWiring for IR Control Wiring the Local Area Network LAN PortRJ-45 Connector Wiring Wiring the Contact Input Port Front Panel Features Front Panel Features OperationSetting Up Power Control of the Output Device Setting Up the System Using the Front PanelFront Panel Security Lockout Executive Mode ResettingPurpose and notes ModeActivation ResultFour times in quick succession, confirming a mode 4 reset Hold the Reset button in until the Power LED blinks oncePurpose and notes This mode is used for troubleshooting Hold the Reset button in until the Power LED blinks twiceConfiguring the Hardware for Ethernet Control Configuration ControlSpace must separate arp and the hyphen Setting Up and Configuring the PC1 Using ARPIPL T PC1 LAN port defaults Setting Up and Configuring the PC1 Using a Web BrowserNetwork Connections Window Setting Up the Computer for IP CommunicationIP address Default gatewayOn the Local Area Connection Properties window, select Enter the following values as shown belowInternet Protocol TCP/IP Properties Window for Windows XP Configuring the IPL T PC1 Using a Web BrowserSystem Settings Page with Default IP Address Password Prompt Window Using the IPL T PC1 Web PagesSystem Status Screen Viewing the System StatusSpecifying system settings Using the Configuration PagesDate and time settings IP settingsContact input port Configuring the RS-232 Port and the AC ReceptacleRS-232 port Using the IR DriversAC receptacle Assigning passwords Performing a commandClick Submit Removing passwordsMail Alerts Page Upper Portion Entering e-mail addressesSetting up Smtp authentication Downloading the firmware from the web Upgrading FirmwareUpdating the firmware Firmware File Selected on the Choose File Window Click Browse to open a Choose file windowSchedule SchedulingTo schedule power on and off to the output receptacle Scheduling output receptacle powerSet Schedule For Field for Executive Mode Scheduling front panel lockout executive modeScheduling by day of the week Managing Files Changing an individual settingUploading files to the web Other file management functions Adding a directoryQuery strings Where x is the SIS command to be executedCustom Web Pages Server Side Includes SSIsWeb Page Html Source Code Document Showing SSIs Code exampleCharacter Hexadecimal Decimal URL encodingReserved characters Special characters Reserved charactersUnsafe characters Accessing and Using Telnet PortConnecting to the IP Address Power Connections TroubleshootingNetwork Connections Response to an Unsuccessful Ping Command Global Configurator SoftwareIPL T PC1 IP address SIS Programming ControlHost-to-Interface Communication Messages Initiated by the IPL T PC1Error Responses Password InformationError Response References Telnet Web Browser Using the Command and Response TablePort and must be hex encoded if non-alphanumeric Symbol Definitions X3# = priority set to Send Data String command parametersX2# X2%X4% X3%X4@ X4$X7$ X6$X7@ X7#Command and Response Table for SIS Commands Example IP Setup Commands Mail CommandsWeb Browser-specific Commands Mail Server Setup CommandsSet GMT offset24 # CZ Remapping Port Designations Password and Security SettingsWeb responses Html sample code File CommandsVar file new Array Telnet text responsesSend a page GET on port 80 followed by WSF See belowTelnet text responses File memoryDefault Reset Zap and Erase CommandsReference Material SpecificationsGeneral IR control interfaceMounting the IPL T PC1 Interface Part Numbers and AccessoriesUnder-desk Mounting Rack mounting procedureMounting the IPL T PC1 Under Furniture Device’s MAC or physical machine address GlossaryNumbers and a Mbps or 100 Mbps10 Mbps or 100 Mbps Addresses in an organization’s networkControls devices On and off by the PC1Standard ports used are 23 for Telnet and 80 for Ethernet HyperText objects from remote web pagesIts corresponding physical MAC address on the LAN Two portsOr networks on the Internet Are used in these commands and responsesPoint at which a device starts to operate at standby power Located, and accessedGlobalViewer, and your custom web pages Configuration or provide you with feedbackEurope USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East
Related manuals
Manual 2 pages 39.09 Kb Manual 27 pages 50.4 Kb

IPL T PC1, IPL T PC1i specifications

The Extron Electronics IPL T PC1 i and IPL T PC1 are advanced presentation and control processors designed for optimal efficiency in various audiovisual applications. These devices serve as integral components in many professional environments, offering sophisticated capabilities for managing and automating AV systems.

Both models feature a robust, intuitive user interface that simplifies the management of complex audiovisual setups. The IPL T PC1 i and IPL T PC1 enable seamless integration with a variety of control systems, enhancing the user experience and providing streamlined operation. With their scalable design, these devices can cater to the needs of small conference rooms to large auditoriums, making them versatile solutions for diverse applications.

One standout feature of the IPL T PC1 i is its support for Extron's GUI Designer software. This powerful tool allows users to create customized graphical user interfaces tailored to specific AV systems, ensuring that control remains user-friendly and accessible. The IPL T PC1 i also supports a wide range of communication protocols, including Ethernet, RS-232, and USB, which facilitates compatibility with multiple devices and technologies.

Both models are equipped with advanced signal processing capabilities. They offer support for high-resolution video formats, ensuring that presentations and multimedia displays maintain their quality. Options for signal routing and switching further enhance the functionality of the devices, allowing for dynamic and adaptive presentations.

The IPL T PC1 i and IPL T PC1 also feature built-in scheduling and automation capabilities. Users can program specific tasks, such as turning systems on or off, adjusting volume levels, and changing input sources, at predetermined times. This feature maximizes efficiency, minimizes the need for manual intervention, and ensures that AV systems are ready when needed.

In terms of physical design, both models are compact and rack-mountable, allowing for easy installation in equipment racks or dedicated AV cabinets. They also include comprehensive diagnostic tools for troubleshooting and system monitoring, ensuring optimal performance and reliability.

Overall, the Extron Electronics IPL T PC1 i and IPL T PC1 stand out as reliable, feature-rich solutions for managing AV systems in a variety of settings, making them a popular choice among AV professionals and institutions alike. Their blend of adaptability, user interface design, and robust signal processing capabilities positions them as leaders in the AV control market.