Extron electronic IPL T PC1i manual Connecting the Display Device

Page 13

5.On the drivers list, locate the model name of your output device. In the row for your device, click on the nnKb link in the Communication Sheet column.

In figure 4, below, the Communication sheet link for a 3M-7340 display has been selected.

Figure 4. Communication Sheet Access

6.The communication sheet (a PDF file) opens. You can view, print, or download it.

7.Wire your display device as described in its communication sheet.

You can also access the Communication Sheets via the Global Configurator software (see the IPL T PC1 Setup Guide for information on using GC3.2).

Connecting the Display Device

To connect the display device to the PC1:

1.Wire an RS-232 cable to the provided 4-pole captive screw connector, as described below. Use only the first three pins of the connector, starting from the left.

a.Connect the wire from the Receive port of the display to the first pin (on the left) of the connector, which plugs into the PC1 Tx (Transmit) port.

b.Connect the wire from the Transmit port of the display to the second pin of the connector, which plugs into the PC1 Rx (Receive) port.

c.Connect the ground wire from the display to the third pin of the connector, which plugs into the PC1 ground (_) port.

RS-232

Tx Rx

+5V

IPL T PC1

Rear Panel

RS-232 Port

Ground ( )

Receive (Rx)

Transmit (Tx)

Bidirectional

Ground ( )

Receive (Rx)

Transmit (Tx)

Display

Device

Figure 5. Connecting an Output Device to the RS-232 Port

2.Plug the cable into the RS-232 receptacle on the PC1 rear panel.

NOTE: The RS-232 port is by default a control port. If you want to use it to

configure the PC1, you must perform a mode 2 reset (see “Resetting” in the “Front Panel Features and Operation” section).

IPL T PC1 • Installation and Rear Panels

7

Image 13
Contents IPL T PC1i IPL T PC1Achtung AvertissementVorsicht PrecaucionFCC Class a Notice Conventions Used in this Guide Software CommandsNotifications Contents IPL T PC1 Contents Introduction FeaturesAbout this Guide About the IPL T PC1IPL T PC1 Introduction Extron IPL T PC1i Application DiagramInstallation Overview Installation Rear PanelThis section describes IPL T PC1 Rear Panel 120 VAC Rear PanelsAccessing the Communication Sheet Connecting CablesRS-232 Port Cabling To connect the display device to the PC1 Connecting the Display DeviceWiring for IR Control Wiring the Local Area Network LAN PortRJ-45 Connector Wiring Wiring the Contact Input Port Front Panel Features Front Panel Features OperationSetting Up Power Control of the Output Device Setting Up the System Using the Front PanelFront Panel Security Lockout Executive Mode ResettingActivation ModeResult Purpose and notesPurpose and notes This mode is used for troubleshooting Hold the Reset button in until the Power LED blinks onceHold the Reset button in until the Power LED blinks twice Four times in quick succession, confirming a mode 4 resetConfiguring the Hardware for Ethernet Control Configuration ControlSpace must separate arp and the hyphen Setting Up and Configuring the PC1 Using ARPIPL T PC1 LAN port defaults Setting Up and Configuring the PC1 Using a Web BrowserNetwork Connections Window Setting Up the Computer for IP CommunicationOn the Local Area Connection Properties window, select Default gatewayEnter the following values as shown below IP addressInternet Protocol TCP/IP Properties Window for Windows XP Configuring the IPL T PC1 Using a Web BrowserSystem Settings Page with Default IP Address Password Prompt Window Using the IPL T PC1 Web PagesSystem Status Screen Viewing the System StatusSpecifying system settings Using the Configuration PagesDate and time settings IP settingsContact input port Configuring the RS-232 Port and the AC ReceptacleRS-232 port Using the IR DriversAC receptacle Assigning passwords Performing a commandClick Submit Removing passwordsMail Alerts Page Upper Portion Entering e-mail addressesSetting up Smtp authentication Downloading the firmware from the web Upgrading FirmwareUpdating the firmware Firmware File Selected on the Choose File Window Click Browse to open a Choose file windowSchedule SchedulingTo schedule power on and off to the output receptacle Scheduling output receptacle powerSet Schedule For Field for Executive Mode Scheduling front panel lockout executive modeScheduling by day of the week Managing Files Changing an individual settingUploading files to the web Other file management functions Adding a directoryCustom Web Pages Where x is the SIS command to be executedServer Side Includes SSIs Query stringsWeb Page Html Source Code Document Showing SSIs Code exampleReserved characters URL encodingSpecial characters Reserved characters Character Hexadecimal DecimalUnsafe characters Accessing and Using Telnet PortConnecting to the IP Address Power Connections TroubleshootingNetwork Connections Response to an Unsuccessful Ping Command Global Configurator SoftwareHost-to-Interface Communication SIS Programming ControlMessages Initiated by the IPL T PC1 IPL T PC1 IP addressError Responses Password InformationError Response References Telnet Web Browser Using the Command and Response TablePort and must be hex encoded if non-alphanumeric Symbol Definitions X2# = priority set to Send Data String command parametersX2% X3#X4@ X3%X4$ X4%X7@ X6$X7# X7$Command and Response Table for SIS Commands Example Web Browser-specific Commands Mail CommandsMail Server Setup Commands IP Setup CommandsSet GMT offset24 # CZ Remapping Port Designations Password and Security SettingsVar file new Array File CommandsTelnet text responses Web responses Html sample codeTelnet text responses See belowFile memory Send a page GET on port 80 followed by WSFDefault Reset Zap and Erase CommandsReference Material SpecificationsGeneral IR control interfaceMounting the IPL T PC1 Interface Part Numbers and AccessoriesUnder-desk Mounting Rack mounting procedureMounting the IPL T PC1 Under Furniture Numbers and a GlossaryMbps or 100 Mbps Device’s MAC or physical machine addressControls devices Addresses in an organization’s networkOn and off by the PC1 10 Mbps or 100 MbpsIts corresponding physical MAC address on the LAN HyperText objects from remote web pagesTwo ports Standard ports used are 23 for Telnet and 80 for EthernetPoint at which a device starts to operate at standby power Are used in these commands and responsesLocated, and accessed Or networks on the InternetGlobalViewer, and your custom web pages Configuration or provide you with feedbackEurope, Africa, and the Middle China East USA, Canada, South America Japan Central AmericaAsia Middle East Europe
Related manuals
Manual 2 pages 39.09 Kb Manual 27 pages 50.4 Kb

IPL T PC1, IPL T PC1i specifications

The Extron Electronics IPL T PC1 i and IPL T PC1 are advanced presentation and control processors designed for optimal efficiency in various audiovisual applications. These devices serve as integral components in many professional environments, offering sophisticated capabilities for managing and automating AV systems.

Both models feature a robust, intuitive user interface that simplifies the management of complex audiovisual setups. The IPL T PC1 i and IPL T PC1 enable seamless integration with a variety of control systems, enhancing the user experience and providing streamlined operation. With their scalable design, these devices can cater to the needs of small conference rooms to large auditoriums, making them versatile solutions for diverse applications.

One standout feature of the IPL T PC1 i is its support for Extron's GUI Designer software. This powerful tool allows users to create customized graphical user interfaces tailored to specific AV systems, ensuring that control remains user-friendly and accessible. The IPL T PC1 i also supports a wide range of communication protocols, including Ethernet, RS-232, and USB, which facilitates compatibility with multiple devices and technologies.

Both models are equipped with advanced signal processing capabilities. They offer support for high-resolution video formats, ensuring that presentations and multimedia displays maintain their quality. Options for signal routing and switching further enhance the functionality of the devices, allowing for dynamic and adaptive presentations.

The IPL T PC1 i and IPL T PC1 also feature built-in scheduling and automation capabilities. Users can program specific tasks, such as turning systems on or off, adjusting volume levels, and changing input sources, at predetermined times. This feature maximizes efficiency, minimizes the need for manual intervention, and ensures that AV systems are ready when needed.

In terms of physical design, both models are compact and rack-mountable, allowing for easy installation in equipment racks or dedicated AV cabinets. They also include comprehensive diagnostic tools for troubleshooting and system monitoring, ensuring optimal performance and reliability.

Overall, the Extron Electronics IPL T PC1 i and IPL T PC1 stand out as reliable, feature-rich solutions for managing AV systems in a variety of settings, making them a popular choice among AV professionals and institutions alike. Their blend of adaptability, user interface design, and robust signal processing capabilities positions them as leaders in the AV control market.