Extron electronic IPL T PC1i manual Under-desk Mounting, Rack mounting procedure

Page 71

Reduced air flow — Install the equipment in the rack so that the amount of air flow required for safe operation of the equipment is not compromised.

Mechanical loading — Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition.

Circuit overloading — When connecting the equipment to the supply circuit, consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Consider equipment nameplate ratings when addressing this concern.

Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (such as the use of power strips).

Rack mounting procedure

To mount the PC1 on a rack shelf:

1.If rubber feet have been installed on the bottom of the unit, remove them.

2.Mount the PC1 on the rack shelf, using two 4-40 x 3/16 inch screws in opposite (diagonal) corners of the unit to secure it to the shelf.

3.Attach a blank panel or other units to the rack shelf.

RSU 129

1U Universal Rack Shelf

1/2 Rack Width Front False

Faceplate

1/4 Rack Width Front False

Faceplate

Both front false faceplates use 2 screws.

(2) 4-40 x 3/16" Screws

Use 2 mounting holes on opposite corners.

Figure 43. Mounting the IPL T PC1 on an RSU 129 Universal Rack Shelf

4.Insert the shelf into the rack, aligning the holes in the shelf with those in the rack.

5.Secure the shelf to the rack using the supplied machine screws. This shelf can be mounted in the front or in the rear of the rack.

Under-desk Mounting

The PC1 can also be mounted under furniture, such as a table or podium surface, using the optional under-desk mounting kit MBU 125 (part number 70-077-01).

1.If rubber feet were previously installed on the bottom of the unit, remove them.

2.Attach the mounting brackets to the unit with the provided machine screws.

3.Insert #8 wood screws into the four pilot holes. Tighten each screw into the mounting surface until slightly less than ¼ inch of the screw protrudes.

4.Align the mounting screws with the slots in the brackets, and place the PC1 against the surface with the screws through the bracket slots.

IPL T PC1 • SIS Programming and Control 65

Image 71
Contents IPL T PC1i IPL T PC1Precaucion AvertissementAchtung VorsichtFCC Class a Notice Notifications Software CommandsConventions Used in this Guide Contents IPL T PC1 Contents About the IPL T PC1 FeaturesIntroduction About this GuideIPL T PC1 Introduction Extron IPL T PC1i Application DiagramThis section describes Installation Rear PanelInstallation Overview IPL T PC1 Rear Panel 120 VAC Rear PanelsRS-232 Port Cabling Connecting CablesAccessing the Communication Sheet To connect the display device to the PC1 Connecting the Display DeviceRJ-45 Connector Wiring Wiring the Local Area Network LAN PortWiring for IR Control Wiring the Contact Input Port Front Panel Features Front Panel Features OperationSetting Up Power Control of the Output Device Setting Up the System Using the Front PanelFront Panel Security Lockout Executive Mode ResettingPurpose and notes ModeActivation ResultFour times in quick succession, confirming a mode 4 reset Hold the Reset button in until the Power LED blinks oncePurpose and notes This mode is used for troubleshooting Hold the Reset button in until the Power LED blinks twiceConfiguring the Hardware for Ethernet Control Configuration ControlSpace must separate arp and the hyphen Setting Up and Configuring the PC1 Using ARPIPL T PC1 LAN port defaults Setting Up and Configuring the PC1 Using a Web BrowserNetwork Connections Window Setting Up the Computer for IP CommunicationIP address Default gatewayOn the Local Area Connection Properties window, select Enter the following values as shown belowInternet Protocol TCP/IP Properties Window for Windows XP Configuring the IPL T PC1 Using a Web BrowserSystem Settings Page with Default IP Address Password Prompt Window Using the IPL T PC1 Web PagesSystem Status Screen Viewing the System StatusSpecifying system settings Using the Configuration PagesDate and time settings IP settingsContact input port Configuring the RS-232 Port and the AC ReceptacleAC receptacle Using the IR DriversRS-232 port Assigning passwords Performing a commandClick Submit Removing passwordsMail Alerts Page Upper Portion Entering e-mail addressesSetting up Smtp authentication Updating the firmware Upgrading FirmwareDownloading the firmware from the web Firmware File Selected on the Choose File Window Click Browse to open a Choose file windowSchedule SchedulingTo schedule power on and off to the output receptacle Scheduling output receptacle powerSet Schedule For Field for Executive Mode Scheduling front panel lockout executive modeScheduling by day of the week Uploading files to the web Changing an individual settingManaging Files Other file management functions Adding a directoryQuery strings Where x is the SIS command to be executedCustom Web Pages Server Side Includes SSIsWeb Page Html Source Code Document Showing SSIs Code exampleCharacter Hexadecimal Decimal URL encodingReserved characters Special characters Reserved charactersUnsafe characters Accessing and Using Telnet PortConnecting to the IP Address Network Connections TroubleshootingPower Connections Response to an Unsuccessful Ping Command Global Configurator SoftwareIPL T PC1 IP address SIS Programming ControlHost-to-Interface Communication Messages Initiated by the IPL T PC1Error Response References Password InformationError Responses Port and must be hex encoded if non-alphanumeric Using the Command and Response TableTelnet Web Browser Symbol Definitions X3# = priority set to Send Data String command parametersX2# X2%X4% X3%X4@ X4$X7$ X6$X7@ X7#Command and Response Table for SIS Commands Example IP Setup Commands Mail CommandsWeb Browser-specific Commands Mail Server Setup CommandsSet GMT offset24 # CZ Remapping Port Designations Password and Security SettingsWeb responses Html sample code File CommandsVar file new Array Telnet text responsesSend a page GET on port 80 followed by WSF See belowTelnet text responses File memoryDefault Reset Zap and Erase CommandsReference Material SpecificationsGeneral IR control interfaceMounting the IPL T PC1 Interface Part Numbers and AccessoriesUnder-desk Mounting Rack mounting procedureMounting the IPL T PC1 Under Furniture Device’s MAC or physical machine address GlossaryNumbers and a Mbps or 100 Mbps10 Mbps or 100 Mbps Addresses in an organization’s networkControls devices On and off by the PC1Standard ports used are 23 for Telnet and 80 for Ethernet HyperText objects from remote web pagesIts corresponding physical MAC address on the LAN Two portsOr networks on the Internet Are used in these commands and responsesPoint at which a device starts to operate at standby power Located, and accessedGlobalViewer, and your custom web pages Configuration or provide you with feedbackEurope USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East
Related manuals
Manual 2 pages 39.09 Kb Manual 27 pages 50.4 Kb

IPL T PC1, IPL T PC1i specifications

The Extron Electronics IPL T PC1 i and IPL T PC1 are advanced presentation and control processors designed for optimal efficiency in various audiovisual applications. These devices serve as integral components in many professional environments, offering sophisticated capabilities for managing and automating AV systems.

Both models feature a robust, intuitive user interface that simplifies the management of complex audiovisual setups. The IPL T PC1 i and IPL T PC1 enable seamless integration with a variety of control systems, enhancing the user experience and providing streamlined operation. With their scalable design, these devices can cater to the needs of small conference rooms to large auditoriums, making them versatile solutions for diverse applications.

One standout feature of the IPL T PC1 i is its support for Extron's GUI Designer software. This powerful tool allows users to create customized graphical user interfaces tailored to specific AV systems, ensuring that control remains user-friendly and accessible. The IPL T PC1 i also supports a wide range of communication protocols, including Ethernet, RS-232, and USB, which facilitates compatibility with multiple devices and technologies.

Both models are equipped with advanced signal processing capabilities. They offer support for high-resolution video formats, ensuring that presentations and multimedia displays maintain their quality. Options for signal routing and switching further enhance the functionality of the devices, allowing for dynamic and adaptive presentations.

The IPL T PC1 i and IPL T PC1 also feature built-in scheduling and automation capabilities. Users can program specific tasks, such as turning systems on or off, adjusting volume levels, and changing input sources, at predetermined times. This feature maximizes efficiency, minimizes the need for manual intervention, and ensures that AV systems are ready when needed.

In terms of physical design, both models are compact and rack-mountable, allowing for easy installation in equipment racks or dedicated AV cabinets. They also include comprehensive diagnostic tools for troubleshooting and system monitoring, ensuring optimal performance and reliability.

Overall, the Extron Electronics IPL T PC1 i and IPL T PC1 stand out as reliable, feature-rich solutions for managing AV systems in a variety of settings, making them a popular choice among AV professionals and institutions alike. Their blend of adaptability, user interface design, and robust signal processing capabilities positions them as leaders in the AV control market.