Tripp Lite TE Series Important Safety Instructions, UPS Location Warnings, Battery Warnings

Page 2

Important Safety Instructions

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. SAVE THESE INSTRUCTIONS.

UPS Location Warnings

Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.

For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).

Leave adequate space around all sides of the UPS for proper ventilation.

UPS Connection Warnings

Connect your UPS to a properly grounded AC power outlet. Do not modify the UPS's plug. Do not use adapters that eliminate the UPS's ground line.

Do not plug your UPS into itself; this will damage the UPS and void your warranty.

If you are connecting your UPS to a motor-powered AC generator, the generator must provide clean, filtered computer-grade output.

Equipment Connection Warnings

Do not use Tripp Lite UPS Systems for life support appliances in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life-support device.

Do not connect surge suppressors to the output of your UPS. This may damage your UPS and will void both the surge suppressor and UPS warranties.

Battery Warnings

Your UPS does not require routine maintenance. Do not open your UPS for any reason. There are no user-serviceable parts inside.

Battery replacement must be performed by qualified service personnel. Because the batteries present a risk of electrical shock and burn from high short-circuit current, observe proper precautions. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles, and replace the existing batteries with the same number and type of new batteries (Sealed Lead-Acid). Do not open the batteries. Do not short or bridge the battery terminals with any object.

The UPS batteries are recyclable. Refer to local codes for disposal requirements, or in the USA only call 1-800-SAV-LEAD for recycling information. Do not dispose of the batteries in a fire.

Do not attempt to add external batteries.

2

Image 2
Contents Quick Installation UPS Location Warnings Important Safety InstructionsBattery Warnings UPS Connection WarningsOptional Installation† Quick InstallationSwitch Test your UPSs battery charge SwitchesSilence the UPS On-Battery alarm Basic OperationIndicator Lights Other UPS FeaturesService Storage & ServiceSpecifications StorageInstalación Rápida Seguridad Advertencias Sobre la InstalaciónSistema UPS a una toma de Instalación RápidaConecte el no-break Regule el interruptor OFF-ON encendido-apagadoInterruptores Silenciar la alarma de apagonesOperación Básica Luces Indicadoras Arranque en frío del no-break / sistema UPSOtras Características de este no-break / Sistema UPS Receptáculos de CAAlmacenaje Almacenaje y ServicioEspecificaciones ServicioInstallation Rapide Mises en garde relatives au raccord de l’équipement Mises en garde relatives à lemplacement du système UPSMises en garde relatives au raccord du système UPS Mises en garde relatives à la batterieInstallation rapide Installation facultative†Commutateurs Amortir l’alarme de la batterie du système UPSExploitation de base Voyants Lumineux Démarrage à froid de votre système UPSAutres Fonctions Prises CAEntreposage Entreposage et EntretienSpécifications Entretien