Tripp Lite SMART1500LCDXL Display Power Conditions, Enable/Disable Alarm, LCD Brightness

Page 5

Basic Operation continued

Display Power Conditions

Use the MODE button to advance through power conditions.

1.Voltage In

2.Voltage Out

3.Estimated Runtime (in minutes)

4.Load %

5.Load Wattage*

6.Battery Capacity %

INPUT

 

1

2

4

5

RUNTIME

MIN

 

3

6

* Load Wattage is displayed in watts up to “999”, and then will be displayed in Kilowatts.

Enable/Disable Alarm

Tap the MODE button repeatedly to advance to the LCD display featuring the icon. Press the

MUTE button to select ON or OFF alarm mode settings. The last option displayed before navigating away from this menu option will be the selected setting.

LCD Brightness

Tap the MODE button repeatedly to advance to the LCD Brightness display marked “LCD”. Press

the MUTE button to select Medium Backlight (default), High Backlight or Dim Backlight. The last option displayed before navigating away from this menu option will be the selected setting.

Note: After 2 minutes of inactivity, the backlight will revert to the Dim setting until a button is pressed.

Self-test

Tap the MODE button repeatedly to advance to the TEST BATT display. Press the MUTE button to initiate the test. The test will last approximately 10 seconds as the UPS switches to battery to test the capacity with a load. Upon completion of the test, the display will indicate PAS or BAD (pass or bad) for 20 seconds, then return to the home screen. Connected equipment can remain on during the test. Do not unplug your UPS, this will remove safe electrical grounding.

5

201103012 933072.indb 5

3/8/2011 1:43:11 PM

Image 5
Contents SMART1500LCDXL Battery Warnings Important Safety InstructionsUPS Location Warnings UPS Connection WarningsQuick Installation LCD Display LCD FeaturesBasic Operation Enable/Disable Alarm Display Power ConditionsLCD Brightness Self-testScroll Control Power SensitivityError Messages External Battery Setting ControlUPS Features FeaturesStorage Storage and ServiceService FCC Part 68 Notice United States Only FCC Notice, Class B Warranty RegistrationTh Street, Chicago, IL 60609 USA Manual del propietario Advertencias sobre la ubicación del UPS Instrucciones de seguridad importantesAdvertencias sobre la conexión del UPS Advertencias sobre la conexión de equiposInstalación rápida Encendido/Apagado de UPS Operación BásicaPantalla LCD Características de LCDOperación Básica continuación Alarma Activada/DesactivadaMuestra las Condiciones de Energía Brillo de LCDSensibilidad de Potencia Control de Calibraciones de Baterías Externas Mensajes de ErrorControl de Desplazamiento de Pantallas Características CaracterísticasServicio AlmacenamientoAnuncios Manuel de l’utilisateur Mise en garde Environnement de l’UPS Consignes de Sécurité ImportantesMise en garde Connexions de l’UPS Mise en garde Connexion d’équipementInstallation rapide On/Off UPS Fonctionnement BasiqueAfficheur à cristaux liquides Caractéristiques de LCDFonctionnement Basique suite Activer/Désactiver l’AlarmeAfficher l’état d’alimentation Luminosité de l’écran LCDSensibilité à la puissance Messages d’erreur Commande de défilementCommande de réglage de la batterie externe Caractéristiques CaractéristiquesEntreposage et Entretien Caractéristiques suiteEntreposage EntretienLimitations DU Matériel Avis201103012 933072.indb 2011 14320 PM