NTI AUDIO/HD VIDEO MATRIX SWITCH
Telnet Interface
The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server listens on port 2000. To access the telnet interface, using the current IP address type the following in a command shell:
telnet 192.168.1.1 2000
The
The factory default password is "admin".
With a proper password sent the
Password Successful
Connection Established
The following commands are now available:
Command | Reply | Description | |
|
|
| |
H(elp) or | Displays the list of commands | Help | |
h(elp) | |||
|
| ||
CS nn,mm | *<CR> | Connect One Output nn To Input mm | |
|
|
| |
CA nn | *<CR> | Connect All Outputs To Input nn | |
|
|
| |
RO nn | *<CR>mm<CR> | Read Connection For Output. | |
Returns the number of the input mm connected to output nn | |||
|
| ||
CC nn | *<CR>nn<CR> | Save Matrix Connections Into Memory Bank nn | |
nn should be between 00 and 99 | |||
|
| ||
RC nn | *<CR>nn<CR> | Restore Matrix Connections From Memory Bank nn | |
nn should be between 00 and 99 | |||
|
| ||
CB nn | *<CR> | Change baud rate of serial line, nn=12(00),24(00),48(00),96(00) | |
Factory default is 9600. | |||
|
| ||
RV 00 | *<CR>string<CR> | Read NTI Version String | |
|
|
| |
RU | *<CR>nn,mm<CR> | Read Unit Size | |
Returns the number of inputs mm and the number of outputs mm | |||
|
| ||
RS | *<CR> | Reset Unit | |
|
|
| |
AS nn,mm | *<CR> | Connect audio input mm to output mm | |
|
|
| |
AA nn | *<CR> | Connect audio input nn to all outputs | |
|
|
| |
AO nn | *<CR>nn<CR> | Read audio connection for output nn | |
|
|
| |
AM nn,mu | *<CR> | Set mute state for output nn | |
mu(te State) = (00=UNMUTE, 01=MUTE) | |||
|
| ||
AV nn,vv | *<CR> | Set volume level for output nn | |
vv is a value between 00 to 99 (see chart page 12) | |||
|
| ||
|
| Read mute, volume for output nn | |
AR nn | *<CR>MU,VV<CR> | MU is 00 if the port is UNMUTED, MU is 01 if the port is MUTED. | |
|
| VV is a value between 00 to 99 (see chart page 12) | |
|
| Set value of Scan Mode dwell time (see page 9) for specific Output | |
Ss nn,dwt | *<CR> | (nn) | |
|
| dwt = | |
Gs nn | *<CR> | Read set Scan Mode dwell time value (dwt) for specific Output (nn) | |
dwt<CR> | in seconds (see also "Scan Mode" on page 9) | ||
| |||
Sa nn,mm | *<CR> | Set scan list of individual output nn to all inputs mm | |
|
|
|