Network Technologies SM-8X4-HDA Command Protocol, Command Good Response Description String

Page 15

NTI AUDIO/HD VIDEO MATRIX SWITCH

Command Protocol

CPU controller commands supported by the unit are defined below. All commands should be terminated with a <CR> (carriage return). When a command is sent, the entire string is echoed back to the CPU along with a response from the addressed unit as shown in the command definitions. All characters should be upper case, and all numbers below 10 should have a leading 0 (ex: 1 = 01).

NOTE: For units with one output or user port, use 01 for the output select.

Legend:

(All numbers must be two digits)

SW

:

Switch (01-15)

MM

:

Save Into Memory Bank (00-09)

BR

:

Baud Rate Code (12,24,48,96)

LL

:

Load From Memory Bank (00-09)

OP

:

Output Port (01-MAXOUTPUTS)

<CR>

:

Carriage Return (Hex 0xD)

IP

:

Input Port (01-MAXINPUTS)

ip

:

IP address

Command

Good Response

Description

String

 

 

CS SW,IP,OP

*<CR>

VIDEO Connect One Output/User Port To Input/CPU Port

CA SW,IP

*<CR>

VIDEO Connect All Output/User Ports To Input/CPU Port

RO SW,OP

*<CR>IP<CR>

VIDEO Read Connection For Output/User Port

AS SW,IP,OP

*<CR>

AUDIO Connect One Output/User Port To Input/CPU Port

AA SW,IP

*<CR>

AUDIO Connect All Output/User Ports To Input/CPU Port

AO SW,OP

*<CR>IP<CR>

AUDIO Read Connection For Output/User Port

AM SW,OP,MU

*<CR>

Set Mute State For Output/User Port

AV SW,OP,VV

*<CR>

Set Volume Level For Output/User Port

 

 

See chart on page 10 for values

AR SW,OP

*<CR>MU,VV<CR>

Read Mute, Volume For Output/User Port

 

 

MU is 00 if the port is UNMUTED, MU is 01 if the port is MUTED.

 

 

VV is a value between 00 to 99 (see chart page 12)

CC SW,MM

*<CR>MM<CR>

Save Matrix Connections Into Memory Bank xx

 

 

Xx=00-09

RC SW,LL

*<CR>LL<CR>

Restore Matrix Connections From Memory Bank

CB 00,BR

None

Change baud rate of serial line, BR=12(00),24(00),48(00),96(00)

 

 

Factory default is 9,600

RS SW

*<CR>

Internal Reset

RV SW,00

*<CR>string\0<CR>

Read NTI Version String

RU SW

*<CR>IP,OP<CR>

Read Unit Size

EA SW,ip

*<CR>

Set the IP address, ip is in xxx.xxx.xxx.xxx format,

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

EM SW,ip

*<CR>

Set the Subnet mask, ip is in xxx.xxx.xxx.xxx format,

 

 

number of digits is minimum 1 and maximum 3 for each field.

 

 

Leading zeroes are accepted

EG SW,ip

*<CR>

Set the default gateway, ip is in xxx.xxx.xxx.xxx format,

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

ET SW,timeout

*<CR>

Set the website timeout; timeout = numeric string of timeout in seconds.

 

 

Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800

RA SW *

<CR>ip<CR>

Read the IP address, ip is in xxx.xxx.xxx.xxx format,

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

RM SW *

<CR>ip<CR>

Read the Subnet mask, ip is in xxx.xxx.xxx.xxx format,

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

RG SW *

<CR>ip<CR>

Read the default gateway, ip is in xxx.xxx.xxx.xxx format,

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

Leading zeroes are accepted

RT SW *

<CR>timeout<CR>

Read the website timeout; timeout = numeric string of timeout in

 

 

seconds.

 

 

Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800

If the first field is not a known command (as listed above) or SW field is different from the serial address programmed in the switch memory, the command will be ignored. If the SW field corresponds to the serial address, but the syntax is wrong after this field, the switch will answer with ?<CR>.

11

Image 15
Contents SM-8X4-HDA Trademark Table of Contents Table of Figures Cables Default User Name and PasswordsIntroduction MaterialsFrontViewofVEEMUX-A Features and FunctionsConnect the Sources Installation+L- R+R Connect the DevicesConnect to the Ethernet Connect RS232Plug in and power up Power UpOutput user number can be entered Control OptionsFront Panel LCD with Keypad Control Escape back to the main display Used to enter numbers. #Saving Connections Volume ControlMemory Functions Menu ButtonScan Mode Unit Address RS232 ControlRemote Connection Baud RateCommand Good Response Description String Command ProtocolMain Options SerTest- RS232 Interface Test ProgramSetup Options Matrix OperationsEthernet Operations Command Reply Description Telnet InterfaceTelnet 192.168.1.1 NTI AUDIO/HD Video Matrix Switch Web Interface Enter the PasswordWeb interface Video Switch Video SwitchWeb interface Audio Switch Audio SwitchWeb interface Setup Setup PagesInput Names Web interface Serial SetupOutput Names Scan ModeWeb interface Update Firmware Update FirmwareLogout Change PasswordUpdate Web Server HelpDevice Discovery Tool Device Discovery ToolLCD Display Features And FunctionsInfrared Control KeypadHow To Use The IRT Change the SwitchPower on with SYS, in or OUT keys Power on with 2 key Change Input Port Change Output PortSet Configuration Replace slide cover on unit Battery ReplacementSpecifications Troubleshooting the IRTRS232 Connection Cables Pinout of RS232 port on VEEMUX-APinouts for typical DCE to DTE cable for CPU connection Pinout for Matrix Y-1 Cable Safety StatementsWiring Schematic of Matrix-Y-1 cable Arrows indicate signal directionMount the VEEMUX-A to a rack Rack Mounting InstructionsSpecifications Solution TroubleshootingWarranty Information Problem