Network Technologies ST-xU operation manual Edit Mode

Page 26

NTI NODEMUX SERIES UNIVERSAL KVM SWITCH

FYI: If switches are cascaded (such as that illustrated in Fig. 14 on page 10), it will be necessary to make note of which port each CPU is connected to on each slave KVM switch and which port each slave KVM switch is connected to on the master KVM switch.

The ports on the slave connected to the port 1 port on the master would be numbered 01-04 with multiple ST-4U’s, the ports on the slave connected to port 2 would be numbered 05-08 (with multiple ST-8U's they would be 01-08, and 09-16, etc.)

A connection to the CPUs from the keyboard would be achieved by typing the appropriate port number. (See Fig. 23 on page 21.)

When cascading, if not all of the ports are used on each slave attached to your system, THE PORT NUMBER(S) ASSOCIATED WITH THE UNUSED PORT(S) WILL NOT BE ACCESSIBLE when trying to control the switches connected to the system. (I.e. if ports 7 and 8 are not used on the first slave and an attempt is made to connect to ports 7 or 8 while in Command Mode, the NODEMUX will ignore the attempt. )

Scan Mode

When in Scan Mode the switch scans to each port with a CPU powered-ON. (The SCAN LED on the front panel will illuminate and remain ON while in Scan Mode.) The port with the CPU powered-ON remains active while in use. When the switch becomes idle for the configured time-out period (default time-out period is 5 seconds) the switch will connect to the next powered-ON CPU port. See Command Mode section above for configuring the scan time-out period.

NOTE: The keyboard and mouse must remain idle for the full scan time-out period before the switch will connect to the next active port.

Broadcast Mode

(use with extreme caution or commands intended for one CPU will be sent to all CPUs)

Broadcast Mode allows the operator to send keystrokes to all active CPUs simultaneously (even those CPUs the user cannot connect to due to lack of security access ). Broadcast Mode is indicated by the illumination of the BROADCAST LED on the front panel. The BROADCAST LED will remain ON while in Broadcast Mode. However, Broadcast Mode has some critical requirements:

BROADCAST LED must be OFF when booting any attached CPUs.

BROADCAST LED must be ON and COMMAND LED must be OFF for keystrokes to reach attached CPUs.

Broadcast Mode is not supported by any ports that have MAC CPUs attached.

Normal Mode

When all of the NODEMUX mode LEDs are OFF the user is in Normal Mode, controlling the CPU to which the user is connected through the NODEMUX.

Edit Mode

Edit Mode allows the user to modify the names of the CPUs connected to the switch. Names of CPUs can be up to 12 characters in length. When in Edit Mode, multiple keystroke combinations are not valid (<SHIFT>+<P>, <CTRL>+<P>, <ALT>+ <P>, and <P> will all type a “P” to the display - lower case letters cannot be typed). After changes have been made the user will be prompted by the menu to save the changes. Answer "Y" to save changes and answer "N" to continue using previously entered port names.

Function:

Move cursor one position to the right

Move cursor one position to the left

Previous port

Next port

Selects the first port on the switch

Keystroke:

Home

Figure 24- Edit Mode

22

Image 26
Contents ST- xU Trademark Table of Contents Table of Figures Available Options FeaturesIntroduction Supported DevicesMaterials Materials SuppliedFeatures and Functions Rackmounting Instructions To Mount to a RackInstallation Dip-switch configurationConnect a PS/2 keyboard and mouse For each CPU Connect a PS/2 CPUSuncpu For Units with Touch-screen support -TSO option Connect a touch-screen monitor to an ST-8U-TS-RCascading LimitationsConfiguration Cascaded InstallationBasic cascaded master-to-slave cable connections Cable RequiredFront Panel Control Basic Command ModeOperation Keyboard ControlBroadcast Mode LED will toggle on and OFF Command Functions Contd Function KeystrokeScan Mode LED will toggle on and OFF Xxx from 002 to 255. ie. t002Security Option Enabling the Security FeatureOSD Control Additional Modes Available With Security User Login ModeAdministration Mode Switch Configuration Configure for CascadingTab Administrator PasswordExit Switch Configuration Mode OSD Command Mode User Access Functions System Access List User Name ListCommand Mode menus Ctrl + E Ctrl + M Ctrl + OCommand Mode Cont’d FunctionKeystroke Edit Mode Edit ModeSearch Mode Esc EnterMaintenance Mode Activate security featuresOSD Touch Screen Support Touch Maintenance ModeHelp Mode OSD Entry Method Reset Default ValuesAlign The Cursor RS232 Connector DB-9 Female RS232 Connections and ConfigurationConfiguration via Dip Switches Remote ConnectionConfiguration via OSD Unit Address and Loop BackLoop Back Unit AddressCommand Protocol Pinout of Matrix-Y-1 cableFormat RU Aacr KEYBOARD-TO-CPU Translation Keyboard key layoutsHOW to Disable Operating Modes Location of jumper blockFor models ST-xU no OSD Case screws must be removedClear access to the jumper block For models ST-xU-O with OSD Component layout in unit with OSD Optional-4 and 8 port models only Configuring the Jumper BlockNON-OSD Touch Screen Support Always turn power on in this sequence TroubleshootingWarranty Information