Network Technologies ST-xU operation manual Rackmounting Instructions, To Mount to a Rack

Page 8

NTI NODEMUX SERIES UNIVERSAL KVM SWITCH

RACKMOUNTING INSTRUCTIONS

This NTI switch was designed to be mounted to a rack or to set on a desktop. It includes rackmount ears to make attachment to a rack easy, and rubber feet to be applied to the bottom of the case if it will instead sit on a flat surface. If this will sit on a flat surface, simply apply the rubber feet to the bottom of the case in each of the 4 corners.

To Mount to a Rack

1.Attach the ears to the switch using the 6-32x3/16" flat Phillips-head screws (6) provided as shown in the illustration below. The holes in the ears should line up with pre-threaded holes in the sides of the NTI switch. Tighten the screws securely.

NTISwitch

FrontofSwitch

6-32x3/16" FlatHead Screws (Provided)

RackmountEar

Figure 1- Secure rackmount ears to switch

2.Install 4 captive nuts (not provided) to the rack in locations that line up with the holes in the mounting ear on the NTI switch.

3.Secure the NTI switch to the rack using four 3/16" diameter screws (not provided). Each screw should be of sufficient length to go completely through the NTI mounting ear, rack frame and fully engage all threads in the captive nut. Be sure to tighten all mounting screws securely.

4.Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.

NTISwitch

Rack

CaptiveNuts

(notprovided)

3/16"DiameterScrews (notprovided)

Figure 2- Secure switch to rack

4

Image 8
Contents ST- xU Trademark Table of Contents Table of Figures Features IntroductionAvailable Options Supported DevicesMaterials Materials SuppliedFeatures and Functions Rackmounting Instructions To Mount to a RackInstallation Dip-switch configurationConnect a PS/2 keyboard and mouse For each CPU Connect a PS/2 CPUSuncpu For Units with Touch-screen support -TSO option Connect a touch-screen monitor to an ST-8U-TS-RCascading LimitationsConfiguration Cascaded InstallationBasic cascaded master-to-slave cable connections Cable RequiredBasic Command Mode OperationFront Panel Control Keyboard ControlCommand Functions Contd Function Keystroke Scan Mode LED will toggle on and OFFBroadcast Mode LED will toggle on and OFF Xxx from 002 to 255. ie. t002Security Option Enabling the Security FeatureOSD Control Additional Modes Available With Security User Login ModeAdministration Mode Switch Configuration Configure for CascadingTab Administrator PasswordExit Switch Configuration Mode User Access Functions System Access ListOSD Command Mode User Name ListCommand Mode menus Ctrl + E Ctrl + M Ctrl + OCommand Mode Cont’d FunctionKeystroke Edit Mode Edit ModeSearch Mode Esc EnterMaintenance Mode Activate security featuresOSD Touch Screen Support Touch Maintenance ModeHelp Mode OSD Entry Method Reset Default ValuesAlign The Cursor RS232 Connections and Configuration Configuration via Dip SwitchesRS232 Connector DB-9 Female Remote ConnectionConfiguration via OSD Unit Address and Loop BackLoop Back Unit AddressCommand Protocol Pinout of Matrix-Y-1 cableFormat RU Aacr KEYBOARD-TO-CPU Translation Keyboard key layoutsHOW to Disable Operating Modes Location of jumper blockFor models ST-xU no OSD Case screws must be removedClear access to the jumper block For models ST-xU-O with OSD Component layout in unit with OSD Optional-4 and 8 port models only Configuring the Jumper BlockNON-OSD Touch Screen Support Always turn power on in this sequence TroubleshootingWarranty Information