NTI NODEMUX SERIES UNIVERSAL KVM SWITCH
CA - change all output channels
FORMAT: | CA AA,XX<CR> |
| CA = "change all outputs" command followed by at least one space |
| AA = unit address |
| XX = input /CPU to connect to all outputs/USERS |
RESPONSE: | *<CR> (command received and executed OK) |
| ?<CR> (syntax or transmission error occurred) |
FYI: In this NODEMUX switch, this command will have the same effect as the CS command above.
RO - read single USER channel
FORMAT: | RO AA,YY<CR> |
| RO = "read output" command followed by at least one space |
| AA = unit address |
| YY = output/USER to read |
RESPONSE: | *<CR> (command received and executed OK) |
| XX<CR> (XX = input/CPU connected) |
|
| ?<CR> (syntax or transmission error occurred) |
RU - read unit size | |
FORMAT: | RU AA<CR> |
| RU = "read unit size" command followed by at least one space |
| AA = unit address |
RESPONSE: | *<CR> (command received and executed OK) |
| XX,YY<CR> (XX = # of CPU’s, YY = # of USERS) |
| |
| ?<CR> (syntax or transmission error occurred) |
RV- read unit software version | |
FORMAT: | RV XX,00 |
RV= "read software version" command followed by at least one space AA= unit address
00= command for the address location in memory of the software version
RESPONSE:
?<CR> (syntax or transmission error occurred)
CF - reset all connected units, regardless of address, to factory default configuration settings
WARNING: THIS COMMAND WILL RESET ALL RS232 DAISY CHAIN CONNECTED NODEMUX SWITCHES TO FACTORY DEFAULT SETTINGS. IF OTHER SWITCHES ARE DAISY CHAINED VIA RS232, DISCONNECT THEM BEFORE SENDING THIS COMMAND.
FORMAT: | CF 00 |
RESPONSE: (After
COMMAND OK
RESET SWITCH CONFIGURATION IS COMPLETE
PLEASE RESET SWITCH POWER
FOR CHANGES TO TAKE EFFECT