Network Technologies ST-xU operation manual Switch Configuration, Configure for Cascading

Page 21

NTI NODEMUX SERIES UNIVERSAL KVM SWITCH

Switch Configuration

Switch Configuration enables the administrator to configure the NODEMUX to be used as a stand alone switch or as one of the switches in a cascaded system. Switch Configuration is also used to setup the communication settings for RS232 communication with a remotely connected terminal through the RS232 port. For the Switch Configuration Mode menu, press <W> from the Administration Mode menu (page 16).

Be careful with this field. If changed to SLAVE, OSD will not work after power cycling.

Figure 19- Switch Configuration Mode screen

Configure for Cascading

By default, the NODEMUX is configured to be used by itself, as a "STAND ALONE SWITCH". If the NODEMUX is going to be

used in a cascaded system of switches (see "Cascading" on page 10)

it must be configured for the application. With the

highlighted cursor bar on the top line, press the <

 

> (up arrow) or <

> (down arrow) to toggle between the following choices:

 

MASTER W/ 4-PORT SLAVES

MASTER W/ 8-PORT SLAVES

MASTER W/ 16-PORT SLAVES

SLAVE UNIT

STAND ALONE SWITCH

Figure 20- Switch configured as a master with one slave attached

A unit configured as a MASTER W/ 4-PORT SLAVES can have up to 8 slaves attached, each with up to 4 ports for CPUs.

A MASTER W/ 8-PORT SLAVES can also have up to 8 slaves attached but those slaves can each have up to 8 CPUs attached. The unit configured as a MASTER W/ 16-PORT SLAVES can have slaves with up to 16 CPUs attached.

With a switch configured as a master, it must also be configured for how many slaves will be connected to it. Move the highlighted cursor bar to "SLAVE COUNT" and press the < > (up arrow) or < > (down arrow) until the number shown reflects the number of slaves being connected to the master.

With the switch configured as a master with one or more slaves, the NODEMUX will automatically sense other switches attached when powered up and list those switches in the Command Mode menu.

If "SLAVE UNIT" is selected, then the Unit number in the configuration must also be selected. No two slaves connected to a master can have the same Unit number. Choose a unit number between 1 and 8 (typically the same number as the port number the slave will be attached to on the master NODEMUX.)

17

Image 21
Contents ST- xU Trademark Table of Contents Table of Figures Introduction FeaturesAvailable Options Supported DevicesMaterials Supplied MaterialsFeatures and Functions To Mount to a Rack Rackmounting InstructionsDip-switch configuration InstallationConnect a PS/2 keyboard and mouse Connect a PS/2 CPU For each CPUSuncpu Connect a touch-screen monitor to an ST-8U-TS-R For Units with Touch-screen support -TSO optionLimitations CascadingCascaded Installation ConfigurationCable Required Basic cascaded master-to-slave cable connectionsOperation Basic Command ModeFront Panel Control Keyboard ControlScan Mode LED will toggle on and OFF Command Functions Contd Function KeystrokeBroadcast Mode LED will toggle on and OFF Xxx from 002 to 255. ie. t002Enabling the Security Feature OSD ControlSecurity Option User Login Mode Administration ModeAdditional Modes Available With Security Configure for Cascading Switch ConfigurationAdministrator Password Exit Switch Configuration ModeTab System Access List User Access FunctionsOSD Command Mode User Name ListCtrl + E Ctrl + M Ctrl + O Command Mode menusCommand Mode Cont’d FunctionKeystroke Edit Mode Edit ModeEsc Enter Search ModeActivate security features Maintenance ModeTouch Maintenance Mode Help ModeOSD Touch Screen Support Reset Default Values Align The CursorOSD Entry Method Configuration via Dip Switches RS232 Connections and ConfigurationRS232 Connector DB-9 Female Remote ConnectionUnit Address and Loop Back Configuration via OSDUnit Address Loop BackPinout of Matrix-Y-1 cable Command ProtocolFormat RU Aacr Keyboard key layouts KEYBOARD-TO-CPU TranslationLocation of jumper block HOW to Disable Operating ModesCase screws must be removed For models ST-xU no OSDClear access to the jumper block For models ST-xU-O with OSD Component layout in unit with OSD Configuring the Jumper Block NON-OSD Touch Screen SupportOptional-4 and 8 port models only Troubleshooting Warranty InformationAlways turn power on in this sequence