25
9. Connecting and configuring DIO ports
<Note> Wire Handling
TrimmingWire
When connecting a wire to a terminal block, follow the instructions below. Note the different types of
wire that can be used.
Standard Wire : Peel off the wiring, cover
8~10mm and solder it. Wire gage should be
AWG22~26.
Solid Wire : Peel off the wiring cover 8~10mm
and solder it. Wire gage should beAWG 20~26
Inserting & removing wire
To insert & remove wirte in T ERMINAL BLOCK,
use a screwdriver in the diagram to the right.

9.1. Connecting and configuring sensor

9.1.1. Specification

In order to run sensor input of eDVR MD3200 Series normally, the following conditions are required.
Input Ch. 16Ch Photo coupler inputs
Input type N.C (Normal Close)/ N.O. (Normal Open) type.
Supported sensor Dry contact sensor
Spec.
Connecting Connecting the trimmed wire to terminal block
Availableinput pulse r ange Min. 500ms
Performance Output current TypicalDC 12 mA