APPENDIX
LAMP REPLACEMENT
LAMP REPLACE
When the life of the Projection Lamp of this projector draws to an end, the LAMP REPLACE indicator lights yellow. If this indicator lights yellow, replace the projection lamp with a new one promptly.
This indicator lights yellow when the life of the projection lamp draws to an end. Replace the Projection Lamp with a new one promptly.
TOP CONTROL
READY
LAMP
REPLACE
RNING LAMP
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CAUTION |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Allow the projector to cool, for at least 45 minutes before | For continued safety, replace with a lamp assembly of |
| |||||
| you open the Lamp Cover. The inside of a projector can |
| the same type. |
| ||||
| become very hot. |
| Do not drop the lamp assembly or touch the glass bulb! |
| ||||
|
|
|
| The glass can shatter and may cause injury. |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Follow these steps to replace the lamp assembly.
1 | Turn off the projector and disconnect the AC plug. Allow the |
projector to cool at least for 45 minutes. | |
2 | To remove the Lamp Cover, remove the screw with a |
screwdriver . | |
3 | Remove the 2 screws with a screwdriver and pull out Lamp |
Assembly by grasping Handle. | |
4 | Replace the Lamp Assembly with a new one and tighten 2 |
screws back into position. Make sure that the Lamp Assembly is | |
| set properly. Replace Lamp Cover and tighten the screw. |
5 | projector.Connect the AC Power Cord to the projector and turn on the |
6 | Reset the Lamp Replace Counter. |
Refer to “LAMP REPLACE COUNTER” on the next page . |
NOTE : Do not reset the Lamp Replace Counter when Projection Lamp is not replaced.
SCREW
LAMP COVER
HANDLE
LAMP
ASSEMBLY
SCREW
ORDER REPLACEMENT LAMP
The Replacement Lamp can be ordered through your dealer. When ordering a Projection Lamp, give the following information to the dealer.
● | Model No. of your projector | : | |
● | Replacement Lamp Type No. | : | |
|
|
| (Service Parts No. 610 300 7267) |
37