Canon LV-X2 To change the code of Projector, To change the code of the Remote Control Unit

Page 36

SETTING

Power management

This function turns the Projection Lamp off when this projector detects signal interruption and is not used for a certain period in order to reduce power consumption and maintain the Lamp-life. (This projector is shipped with this function ON.)

Power Management function operates to turn the Projection Lamp off when the input signal is interrupted and any button is not pressed over 5 minutes. This function operates as follows;

1.When any input signal is interrupted, “No signal” and the count down display appears (for 5 minutes).

2.After counting down for 5 minutes, the Projection Lamp and the READY Indicator are turned off. (Cooling Fans keep running.)

3.The READY Indicator starts to flash after cooling down the Projection Lamp about for 90 seconds (Power Management mode).

In this Power Management mode, the Projection Lamp is automatically turned on when the input signal is connected or the projector is operated with any button on the Top Control or on the Remote Control Unit again.

Remote control

This projector has two different remote control codes; the factory-set normal code (Code 1) and the secondary code (Code 2). This switching function prevents remote control interference when operating several projectors or video equipment together.

When operating projector in “Code 2,” both projector and Remote Control Unit must be switched to “Code 2.”

To change the code of Projector;

Set the Remote control in the SETTING MENU to “Code 2.”

To change the code of the Remote Control Unit;

Press both the MENU and the IMAGE buttons on the Remote Control Unit together for over 10 seconds.

After changing the code, make sure the Remote Control Unit operates properly.

To return to the normal code (Code 1), repeat the steps above.

NOTE : When the battery of Remote Control Unit is replaced, the remote control code automatically returns to the normal code (Code 1).

Lamp counter reset

This function is used to reset the Lamp Replace Counter. When replacing the Projection Lamp, reset the Lamp Replace Counter by using this function. Refer to page 38 for operation.

Time left until Lamp off.

36

Image 36
Contents LV-X2 To the Owner Safety Instructions Voor de klanten in NederlandCompliances Federal Communication Commission NoticeTable of Contents Features and Design Wide Zoom LensPreparation NomenchtorHOT AIR Exhausted SETTING-UP the Projector Connecting AC Power CordFor Continental Europe Adjustable Feet Preparation Positioning the ProjectorRoom Light Preparation Mounting the Lens Cover Moving the ProjectorConnecting the Projector Terminals of the ProjectorVideo AV AudioConnecting to a Computer Terminals ProjectorConnecting Video Equipment Audio OUTOperation of the Remote Control Unit Before OperationRemote Control Unit Battery Installation BatteryBefore Operation Operating Range TOP Controls and Indicators Ready IndicatorHOW to Operate the ON-SCREEN Menu Operating the ON-SCREEN MenuFlow of ON-SCREEN Menu Operation Before Operation Menu BAR Guide WindowBasic Operation Turning on / OFF the ProjectorTurning on the Projector Turning OFF the ProjectorAdjusting the Screen Zoom AdjustmentFocus Adjustment Keystone AdjustmentSound Adjustment Timer FunctionBasic Operation No Show Function Direct OperationComputer Input Selecting the Input SourceSelecting the Computer System AutoComputer Input Compatible Computer Specifications ResolutionFreq KHzPC Adjustment Auto PC AdjustmentPC Adjust Menu Auto PC AdjComputer Input Manual PC Adjustment Display area Display area HFull screen Picture Image Adjustment Image Level Select DirectImage Level Select Menu Image Select MenuComputer Input Image Level Adjustment Image Adjust MenuPicture Screen Adjustment Screen MenuVideo Input VideoSelecting the Video System AutoAV System Menu Video or S-VIDEO AV System Menu Component VideoCinema Video Input Image Level Adjustment Reset all adjustment to the previous figure Setting Setting MenuSetting Menu To change the code of the Remote Control Unit Power managementRemote control Lamp counter resetLamp Replacement AppendixLamp Replace Lamp Handling Precautions Appendix Lamp Replace CounterMaintenance AIR Filter Care and CleaningCleaning Projection Lens RecommendationTroubleshooting Remote Control Unit Does not workTechnical Specifications Optional PartsAppendix Configurations of the Terminals Control Port ConnectorUSB Connector Series B Computer Input Terminal AnalogCanon U.S.A., INC