Rackmount Solutions XRT Series manual Options

Page 26

WARNING EVENTS

Line Voltage Regulation

The UPS will warn you when the incoming utility power exceeds its normal limits. On the LED front panel the Voltage Regulator LED will light, indicating the incoming voltage is out of range. On the LCD front panel, you will see a “Low Voltage In” or “High Voltage In” message. In either case the audible alarm will not sound.

Output Voltage Switching

The Output of the UPS may be turned OFF or ON by any of three ways other than the power switch. The XRT1000 and above output AC may be manually turned on or off by selecting the Output On or Off command in the SETUP menu. In all models the output may be turned on or off via the RS-232 Serial port or by using the user supplied Output Power Off switch. The XRT1000 and above units will notify you by the “OUT OFF Ext CNTL” screen if the output was turned off from the RS-232 command, or “OUT OFF Man CNTL” screen if the output was turned off from the Output Power Off switch (see the SETUP menu section). The XRT600 does not have this reporting feature, but if no power is being supplied from the UPS and the AC Power LED is lit, then the probable reason is that the output has been turned off.

OPTIONS

The options available for the XRT series UPS’s are in three categories.

Battery Packs

Multiple XRTBP1 and XRTBP3 battery packs may be ordered to configure your system for various loads and battery runtimes. A short table of loads and battery packs for the expected run times are shown in the GENERAL PRODUCT SPECIFICATIONS section.

Software

Complete power management software is available from Minuteman as an option.

Back-panel Receptacles

Standard back-panel receptacle configurations for the various XRT models are shown in the GENERAL PRODUCT SPECIFICATIONS section of this manual. Special configurations can be ordered directly from Minuteman.

25

Image 26
Contents Page Page XRT Series User’s Manual Introduction Para Systems Life Support PolicyPage Radio Frequency Interference Receiving InspectionPlease Save the Packing Materials Important Safety Instructions This Manual Contains Important Safety InstructionsInstructions Importantes Concernant LA Sécurité System Description Features Built in Self Test Protection Strategies InstallationInstallation Placement Page INSTALLATION, Step by Step Battery Pack Connection DiagramXRT600, XRT1000, XRT1500 and XRT2000 Back panels XRT600 Front Panel Showing Load LED’s Front Panel Load Menu on LCD Screen LED Front Panel Top four LED’s Green provide 3 functions OperationFront Panels Second bottom row of LED’s provide status informationStartup SwitchesTest/Alarm Silence Button Menu Flow Status Menu Test Menu Setup Menu Config Menu Alarms and Warnings Options System Batteries Storage InstructionsBattery Replacement Troubleshooting Symptom Possible Cause Action to TakeInitial Error Messages Model XRT1000 and above error messages LCD Display Possible Cause Action to TakeOperating Faults Self Test Obtaining Service Mark the RMA # on the outside of all packages. The factoryPage General Product Specifications Cetl CSA Remote Communications Remote Direct Communications LBWBattery Pack and Runtime Specifications XRT600Load TWO R E E XRTBP1 XRTBP3 Limited Product Warranty