Rackmount Solutions XRT Series manual Switches, Test/Alarm Silence Button, Startup

Page 19

Switches

The Power switch turns the unit on and off. To start the UPS when AC power is not available, press and hold the DC Start button for about 5 seconds.

The Test/Alarm Silence Button

The Test/Alarm Silence button allows you to run the quick self test when the UPS is in the normal mode. If an error was detected and you wish to reset the error display, press the Test/Alarm Silence button.

LCD FRONT PANEL

The XRT1000 through XRT2000 units have a 32 character LCD display, three push buttons, and the Power On and DC Start switches. (Both 120 and 220 VAC versions)

The Power On and DC Start switch operate the same as the XRT600.

The LCD display will step you through all of the functions of the UPS. The top line of the display indicates the parameter and function, and the bottom line displays the function of the three buttons below the display.

Startup

When the unit is first turned on, the self test is executed and the message “Startup Diagnostics” is displayed. After successful completion of the self test, the message “MINUTEMAN Model XRTxxxx” will be displayed for 5 seconds. The “On-Line xxx% Load” menu then appears. If the self test was not successful, or if an error event occurred the last time the UPS was powered on, then the message “Error Detected” will be shown on the top line of the display and the actual error message is shown on the second line (see the Initial Error Message list in the TROUBLESHOOTING section). Pressing any button will clear the message and allow the unit to power up and show one of two messages.

18

Image 19
Contents Page Page XRT Series User’s Manual Para Systems Life Support Policy IntroductionPage Please Save the Packing Materials Receiving InspectionRadio Frequency Interference This Manual Contains Important Safety Instructions Important Safety InstructionsInstructions Importantes Concernant LA Sécurité System Description Features Built in Self Test Installation Placement InstallationProtection Strategies Page Battery Pack Connection Diagram INSTALLATION, Step by StepXRT600, XRT1000, XRT1500 and XRT2000 Back panels XRT600 Front Panel Showing Load LED’s Front Panel Load Menu on LCD Screen Second bottom row of LED’s provide status information OperationFront Panels LED Front Panel Top four LED’s Green provide 3 functionsTest/Alarm Silence Button SwitchesStartup Menu Flow Status Menu Test Menu Setup Menu Config Menu Alarms and Warnings Options Storage Instructions System BatteriesBattery Replacement Symptom Possible Cause Action to Take TroubleshootingInitial Error Messages LCD Display Possible Cause Action to Take Model XRT1000 and above error messagesOperating Faults Self Test Mark the RMA # on the outside of all packages. The factory Obtaining ServicePage General Product Specifications Cetl CSA Remote Communications LBW Remote Direct CommunicationsXRT600 Battery Pack and Runtime SpecificationsLoad TWO R E E XRTBP1 XRTBP3 Limited Product Warranty