Rackmount Solutions PRO500E, PRO700iE, PRO1500E, PRO700E English, Authorized Service Personnel Only

Page 4
AUTHORIZED SERVICE PERSONNEL ONLY.

CAUTION! Connect the UPS to a two pole, three wire grounding Manual backgroundManual backgroundManual background AC wall outlet. The receptacle must be connected to the appropriate Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background branch protection (circuit breaker or fuse). Connection to any other Manual background type of receptacle may result in a shock hazard and violate local elec- trical codes.

CAUTION! To reduce the risk of electrical shock in conditions where

the load equipment grounding cannot be verified, disconnect the UPS

from the AC wall outlet before installing a computer interface cable.

Reconnect the power cord only after all signaling connections are made.

English

WARNING: Risk of Electrical Shock. Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected.

To de-energize the outputs of the UPS:

1.If the UPS is on press and release the On/Off/Test button.

2.Disconnect the UPS from the AC wall outlet.

3.To de-energize the UPS completely, disconnect the battery.

This Uninterruptible Power Supply (UPS) contains potentially hazardous volt- ages. DO NOT attempt to disassemble the UPS. This UPS contains no user serviceable parts. Repairs and battery replacement must be performed by

AUTHORIZED SERVICE PERSONNEL ONLY.

NOTICE: This equipment has been tested and found to comply with

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background the limits for a Class B computing device in accordance with the speci- Manual background fications in Subpart J of Part 15 of FCC Rules and the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference of

the Canadian Department of Communications. These limits are designed to provide reasonable protection against such interference in a residential installa- tion. This equipment generates and uses radio frequency and if not installed and used properly, that is, in strict accordance with the manufacturer's instruc- tions, this equipment may cause interference to radio and television reception. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

!Re-orient the receiving antenna.

!Relocate the computer with respect to the receiver.

!Move the computer away from the receiver.

!Plug the computer into a different outlet so that the computer and receiver are on different branch circuits.

!Shielded communications interface cables must be used with this product.

WARNING: Changes or modifications to this unit not expressly ap- proved by the party responsible for compliance could void the user's authority to operate the equipment.

3

Image 4
Contents Page PRO-E Series Users Manual IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This symbol indicates ATTENTIONThis symbol indicates Risk of Electrical Shock This symbol indicates Direct Current SupplyAUTHORIZED SERVICE PERSONNEL ONLY Receiving Inspection Para Systems Life Support PolicyOn-Line/On-Battery/Boost/Buck LED Fault LED Overload LED REAR PANEL 120V ModelsWARNING The 230V models are NETWORK PROTECTION ONLY 230V ModelsINSTALLATION INSTALLATION PLACEMENTCONNECTING YOUR EQUIPMENT CONNECTING THE UPS TO AN AC SOURCE CHECKING THE SITE WIRING FAULTCHARGING THE BATTERY COMMUNICATIONS PORT CONNECTION OPTIONALDIP SWITCH SETTINGS TURNING THE UNIT ON/OFFON / OFF / Test Button SELF TESTALARMS ON BATTERY LOW BATTERY WARNINGWEAK/BAD BATTERY UPS FAULTCOMMUNICATIONS PORTS RS232 and USB Check the specifications see EnglishPress and release the On/Off even though there isREPLACING THE BATTERY BATTERY REPLACEMENT PROCEDURE Yuasa9. Disconnect the positive red wire from the battery positve terminal IF THE UPS REQUIRES SERVICE MODEL NUMBER PRO500EPRO700E PRO1100EDefault These items may require optional software or hardwareFunction FactoryPara Systems Inc. Para Systems warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of three years from the date of purchase. For equip- ment sites within the United States and Canada, this warranty covers repair or replacement of defective equipment at the discretion of Para Systems. Repair will be from the nearest authorized service center. Replacement parts and warranty labor will be borne by Para Systems. For equipment located outside of the United States and Canada, Para Systems only covers faulty parts. Para Systems products repaired or replaced pursuant to this warranty shall be war- ranted for the unexpired portion of the warranty applying to the original product. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase LIMITED PRODUCT WARRANTY ContinuedRobert Calhoun DECLARATION OF CONFORMITYEnglish